A Longitudinal Study of Remodeling in a Revised Peripheral Artery Bypass Graft Using 3D Ultrasound Imaging and Computational Hemodynamics
- 23 March 2011
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 133 (4) , 041008
Abstract
We report a study of the role of hemodynamic shear stress in the remodeling and failure of a peripheral artery bypass graft. Three separate scans of a femoral to popliteal above-knee bypass graft were taken over the course of a 16 month period following a revision of the graft. The morphology of the lumen is reconstructed from data obtained by a custom 3D ultrasound system. Numerical simulations are performed with the patient-specific geometries and physiologically realistic flow rates. The ultrasound reconstructions reveal two significant areas of remodeling: a stenosis with over 85% reduction in area, which ultimately caused graft failure, and a poststenotic dilatation or widening of the lumen. Likewise, the simulations reveal a complicated hemodynamic environment within the graft. Preliminary comparisons with in vivo velocimetry also showed qualitative agreement with the flow dynamics observed in the simulations. Two distinct flow features are discerned and are hypothesized to directly initiate the observed in vivo remodeling. First, a flow separation occurs at the stenosis. A low shear recirculation region subsequently develops distal to the stenosis. The low shear region is thought to be conducive to smooth muscle cell proliferation and intimal growth. A poststenotic jet issues from the stenosis and subsequently impinges onto the lumen wall. The lumen dilation is thought to be a direct result of the high shear stress and high frequency pressure fluctuations associated with the jet impingement.Keywords
This publication has 37 references indexed in Scilit:
- Adaptive changes in autogenous vein grafts for arterial reconstruction: Clinical implicationsJournal of Vascular Surgery, 2010
- Correlations Among Indicators of Disturbed Flow at the Normal Carotid BifurcationJournal of Biomechanical Engineering, 2009
- Early remodeling of lower extremity vein grafts: Inflammation influences biomechanical adaptationJournal of Vascular Surgery, 2008
- Blood Flow in End-to-Side AnastomosesAnnual Review of Fluid Mechanics, 2008
- Early biomechanical changes in lower extremity vein grafts—distinct temporal phases of remodeling and wall stiffnessJournal of Vascular Surgery, 2006
- Computational investigations of a new prosthetic femoral-popliteal bypass graft designJournal of Vascular Surgery, 2005
- Pulsatile Flow in the Human Left Coronary Artery Bifurcation: Average ConditionsJournal of Biomechanical Engineering, 1996
- Mechanical Factors Associated With the Development of Intimal and Medial Thickening in Vein Grafts Subjected to Arterial PressureHypertension, 1995
- Evidence that turbulence is not the cause of poststenotic dilatation in rabbit carotid arteries.Arteriosclerosis and Thrombosis: A Journal of Vascular Biology, 1993
- Differential response of arteries and vein grafts to blood flow reductionJournal of Vascular Surgery, 1993