Abstract
In the area of biomimetics, engineers use inspiration from natural systems to develop technical devices, such as sensors. One example is the lateral line system of fish. It is a mechanoreceptive system consisting of up to several thousand individual sensors called neuromasts, which enable fish to sense prey, predators, or conspecifics. So far, the small size and high sensitivity of the lateral line is unmatched by man-made sensor devices. Here, we describe an artificial lateral line system based on an optical detection principle. We developed artificial canal neuromasts using MEMS technology including thick film techniques. In this work, we describe the MEMS fabrication and characterize a sensor prototype. Our sensor consists of a silicon chip, a housing, and an electronic circuit. We demonstrate the functionality of our μ-biomimetic flow sensor by analyzing its response to constant water flow and flow fluctuations. Furthermore, we discuss the sensor robustness and sensitivity of our sensor and its suitability for industrial and medical applications. In sum, our sensor can be used for many tasks, e.g. for monitoring fluid flow in medical applications, for detecting leakages in tap water systems or for air and gas flow measurements. Finally, our flow sensor can even be used to improve current knowledge about the functional significance of the fish lateral line.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (FK01RB0902)
This publication has 68 references indexed in Scilit:
- The functional significance of lateral line canal morphology on the trunk of the marine teleost Xiphister atropurpureus (Stichaeidae)Journal of Comparative Physiology A, 2013
- Nonlinear estimation-based dipole source localization for artificial lateral line systemsBioinspiration & Biomimetics, 2013
- Underwater tracking of a moving dipole source using an artificial lateral line: algorithm and experimental validation with ionic polymer–metal composite flow sensorsSmart Materials and Structures, 2013
- Hydrodynamic pressure sensing with an artificial lateral line in steady and unsteady flowsBioinspiration & Biomimetics, 2012
- Controllable silicon nano-grass formation using a hydrogenation assisted deep reactive ion etchingMaterials Science in Semiconductor Processing, 2011
- Improvement of the MEMS bionic vector hydrophoneMicroelectronics Journal, 2011
- Nanograss and nanostructure formation on silicon using a modified deep reactive ion etchingApplied Physics Letters, 2010
- Factorial experimental design applied to DRIE for optimised process in power electronics applications requiring high-aspect ratio trenchesMicrosystem Technologies, 2009
- Distant touch hydrodynamic imaging with an artificial lateral lineProceedings of the National Academy of Sciences, 2006
- Parameter optimization for an ICP deep silicon etching systemMicrosystem Technologies, 2006