Defibrillation Thresholds in Hypertrophic Cardiomyopathy
Authors:
- 23 November 2010
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (5) , 569-572
Abstract
Defibrillation threshold (DFT) testing is performed in part to ensure an adequate safety margin for the termination of spontaneous ventricular arrhythmias. Left ventricular mass is a predictor of high DFTs, so patients with hypertrophic cardiomyopathy (HCM) are often considered to be at risk for increased defibrillation energy requirements. However, there are little prospective data addressing this issue. To assess DFTs in patients with HCM and evaluate the clinical predictors of elevated DFTs. Eighty-nine consecutive patients with HCM and 600 control patients with ischemic or nonischemic cardiomyopathy underwent a uniform modified step-down DFT testing protocol. DFT was compared between the control and HCM populations. Predictors of elevated DFT were evaluated in the HCM group. There was no difference in DFT between HCM and control groups (10.4 ± 5.8 J vs 11.2 ± 5.6 J, respectively). Among patients with HCM, clinical parameters such as left ventricular ejection fraction, interventricular septal thickness, left ventricular mass, and QRS duration were not predictive of an elevated DFT. Only 3 patients (3.4%) with HCM had a DFT >20 J. Patients with HCM do not have elevated DFTs as compared to more typical populations undergoing implantable cardioverter-defibrillator implant; high-energy devices or complex lead systems are not needed routinely in this population.Keywords
This publication has 21 references indexed in Scilit:
- Canadian Registry of ICD Implant Testing Procedures (CREDIT): Current Practice, Risks, and Costs of Intraoperative Defibrillation TestingJournal of Cardiovascular Electrophysiology, 2010
- Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: Do we really need it?American Heart Journal, 2010
- No Benefit From Defibrillation Threshold Testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)JACC, 2008
- ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesJACC, 2008
- Recommendations for Chamber Quantification: A Report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, Developed in Conjunction with the European Association of Echocardiography, a Branch of the European Society of CardiologyJournal of the American Society of Echocardiography, 2005
- Cardioverter-defibrillator implantation in high-risk patients with hypertrophic cardiomyopathyHeart Rhythm, 2005
- Clinical Predictors of Transvenous Defibrillation Energy RequirementsThe American Journal of Cardiology, 1997
- Effects of Waveform and Polarity on Defibrillation Thresholds in Humans Using a Transvenous Lead SystemThe American Journal of Cardiology, 1996
- Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation systemJACC, 1995
- Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study.Circulation, 1992