Radiographic evaluation of immediately loaded implants supporting 2–3 units fixed bridges in the posterior maxilla: a 3‐year follow‐up prospective randomized controlled multicenter clinical study
- 9 February 2015
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 27 (4) , 399-405
Abstract
Objective: To compare the survival rate and alveolar bone levels at implants installed in healed sites and functionally loaded within 1 h from installation or after 3 months.Material and methods: A total of 30 patients (17 male and 13 female) were recruited and 71 implants with a SLA® surface, 4.1 mm in diameter and 8–12 mm long, were installed in a fully healed alveolar ridge, 36 as test and 35 as control implants. The test implants were immediately loaded with a temporary reconstruction in proper occlusion, while the randomly selected control sites received the final reconstruction after 3 months. Radiographic bone levels were determined after implant installation, prosthesis delivery, and at annual intervals thereafter.Results: One patient of the control and one patient of the test were excluded from evaluation. No further losses of implants or patients were seen up to the 3‐year follow‐up. Hence, data from 28 patients were accounted for. A total of 37 and 36 metal–ceramic crowns were provided at the test and control sites, respectively. No biological and technical complications were observed during the 3‐year follow‐up. Bone levels at the time of implant installation were at 1.6 ± 0.8 and 1.7 ± 0.9 mm from the implant shoulder at the test and control sites, respectively. At prosthesis delivery, the bone levels were located at 2.4 ± 0.7 mm at the control sites 3 months after implant placement. After 1 year of function, similar bone levels were observed at both sites, displaying 2.4 ± 1.0 and 2.5 ± 0.8 mm at the test and control sites, respectively. No differences were found in the subsequent observation periods.Conclusion: Survival rates and radiographic bone levels after 1, 2, and 3 years of observation did not differ between conventionally installed implants loaded immediately or delayed (after 3 months). Moreover, insertion torque values did not affect osseointegration.Keywords
Funding Information
- ARDEC, Ariminum Odontologica SRL
- Clinical Research Foundation (CRF)
This publication has 26 references indexed in Scilit:
- Marginal Bone Level Changes at Dental Implants after 5 Years in Function: A Meta-AnalysisClinical Implant Dentistry and Related Research, 2011
- Early loading of single crowns supported by 6‐mm‐long implants with a moderately rough surface: a prospective 2‐year follow‐up cohort studyClinical Oral Implants Research, 2010
- A comparison between immediate loading and immediate restoration in cases of partial posterior mandibular edentulism: a 3‐year randomized clinical trialClinical Oral Implants Research, 2010
- Immediate vs. early loading of dental implants: 3‐year results of a randomized controlled clinical trialClinical Oral Implants Research, 2010
- Immediate non‐occlusal vs. early loading of dental implants in partially edentulous patients: a multicentre randomized clinical trial. Peri‐implant bone and soft‐tissue levelsClinical Oral Implants Research, 2008
- Immediate loading of single SLA implants: drilling vs. osteotomes for the preparation of the implant siteClinical Oral Implants Research, 2007
- Histologic and Histomorphometric Findings From Retrieved, Immediately Occlusally Loaded Implants in HumansJournal of Periodontology, 2005
- The use of reduced healing times on ITI® implants with a sandblasted and acid‐etched (SLA) surface:Clinical Oral Implants Research, 2002
- Dimension of the periimplant mucosaJournal of Clinical Periodontology, 1996
- The effect of subcrestal placement of the polished surface of ITI® implants on marginal soft and hard tissuesClinical Oral Implants Research, 1996