A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections
Open Access
- 10 November 2021
- journal article
- research article
- Published by Wiley in Global Change Biology
- Vol. 28 (4) , 1446-1457
Abstract
Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH4) and nitrous oxide (N2O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N2O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N2O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N2O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N2O sensor was tested at a corn (Zea maysL.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N2O EC fluxes showed excellent agreement with those made with static chambers (m = 1.0 ± 0.3;r2 = .96). More generally, we identified absorption lines for CO2and CH4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.Keywords
Funding Information
- National Science Foundation (DEB‐1359538, DEB 1832042)
- U.S. Department of Energy (DE‐SC0011288, DE‐SC0018409)
This publication has 26 references indexed in Scilit:
- Non-CO2 greenhouse gases and climate changeNature, 2011
- Pressure correction to the long-term measurement of carbon dioxide fluxAgricultural and Forest Meteorology, 2011
- Uncertainties in eddy covariance flux measurements assessed from CH4 and N2O observationsAgricultural and Forest Meteorology, 2010
- N2O exchange over managed grassland: Application of a quantum cascade laser spectrometer for micrometeorological flux measurementsAgricultural and Forest Meteorology, 2010
- A fault-tolerant eddy covariance system for measuring CH4 fluxesAgricultural and Forest Meteorology, 2010
- Novel design of an enclosed CO2/H2O gas analyser for eddy covariance flux measurementsTellus B: Chemical and Physical Meteorology, 2010
- Large tundra methane burst during onset of freezingNature, 2008
- A multi-site analysis of random error in tower-based measurements of carbon and energy fluxesAgricultural and Forest Meteorology, 2006
- Experimental Test of Density and Energy‐Balance Corrections on Carbon Dioxide Flux as Measured Using Open‐Path Eddy CovarianceAgronomy Journal, 2003
- Correction of flux measurements for density effects due to heat and water vapour transferQuarterly Journal of the Royal Meteorological Society, 1980