Evaluation of an electrical impedance tomography-based global inhomogeneity index for pulmonary ventilation distribution
- 4 August 2009
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 35 (11) , 1900-1906
Abstract
To evaluate the plausibility, stability, and interindividual comparability of the global inhomogeneity index (GI) based on electrical impedance tomography (EIT). The lung area in an EIT image was identified by using the lung area estimation method, which mirrors the lung regions in the functional EIT image and subsequently subtracts the cardiac-related areas. The tidal EIT image, showing the difference in impedances between end-inspiration and end-expiration, was calculated and the variations in its pixel values within the predefined lung area were then used as an indicator of inhomogeneous ventilation (the GI index). Fifty patients were investigated including 40 patients tracheally intubated with double-lumen tubes (test group) and 10 patients under anesthesia without pulmonary disease (control group). Positive end-expiratory pressure (PEEP) of 5 mbar was applied in the test group during both two-lung ventilation (TLV) and subsequent one-lung ventilation (OLV). The patients of the control group were ventilated without PEEP. EIT data were recorded in both groups. A significantly lower GI value was found in the control group (0.40 ± 0.05, P = 0.025 vs. TLV 0.74 ± 0.47 and P < 0.002 vs. OLV 1.51 ± 1.45). A significant difference was also found in the test group between TLV and OLV (P < 0.002). If GI was calculated only in the ventilated lung area during OLV (0.71 ± 0.32), it did not significantly differ from the test group during TLV. The GI index quantifies the gas distribution in the lung with a single number and reveals good interpatient comparability.Keywords
This publication has 36 references indexed in Scilit:
- Performance of electrical impedance tomography in detecting regional tidal volumes during one‐lung ventilationActa Anaesthesiologica Scandinavica, 2008
- Improvements in the image quality of ventilatory tomograms by electrical impedance tomographyPhysiological Measurement, 2008
- Electrical impedance tomography guided ventilation therapyCurrent Opinion in Critical Care, 2007
- Tidal Volumes in Patients with Normal LungsAnesthesiology, 2007
- Regional filling characteristics of the lungs in mechanically ventilated patients with acute lung injuryEuropean Journal of Anaesthesiology, 2007
- Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EITPhysiological Measurement, 2006
- Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomographyActa Anaesthesiologica Scandinavica, 2006
- Regional pressure volume curves by electrical impedance tomography in a model of acute lung injuryCritical Care Medicine, 2000
- Dielectric properties of lung tissue as a function of air contentPhysics in Medicine & Biology, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986