Finite Element Analysis (FEA) of a Premaxillary Device: A New Type of Subperiosteal Implant to Treat Severe Atrophy of the Maxilla
Authors:
- Alessandro CipollinaACAlessandro Cipollina
- Mario CeddiaMCMario Ceddia
- Natalia Di PietroNatalia Di Pietro
- Francesco InchingoloFrancesco Inchingolo
- Margherita TumedeiMargherita Tumedei
- Tea RomascoTea Romasco
- Adriano PiattelliAdriano Piattelli
- Alessandro SpecchiulliASAlessandro Specchiulli
- Bartolomeo TrentadueBTBartolomeo Trentadue
Open Access
- 31 July 2023
- journal article
- research article
- Published by MDPI AG in Biomimetics
- Vol. 8 (4) , 336
Abstract
Extreme atrophy of the maxilla still poses challenges for clinicians. Some of the techniques used to address this issue can be complex, risky, expensive, and time consuming, often requiring skilled surgeons. While many commonly used techniques have achieved very high success rates, complications may arise in certain cases. In this context, the premaxillary device (PD) technique offers a simpler approach to reconstruct severely atrophic maxillae, aiming to avoid more complicated and risky surgical procedures. Finite element analysis (FEA) enables the evaluation of different aspects of dental implant biomechanics. Our results demonstrated that using a PD allows for an optimal distribution of stresses on the basal bone, avoiding tension peaks that can lead to bone resorption or implant failure. ANSYS® was used to perform localized finite element analysis (FEA), enabling a more precise examination of the peri-crestal area and the PD through an accurate mesh element reconstruction, which facilitated the mathematical solution of FEA. The most favorable biomechanical behavior was observed for materials such as titanium alloys, which helped to reduce stress levels on bone, implants, screws, and abutments. Additionally, stress values remained within the limits of basal bone and titanium alloy strengths. In conclusion, from a biomechanical point of view, PDs appear to be viable alternatives for rehabilitating severe atrophic maxillae.Keywords
All Related Versions
This publication has 60 references indexed in Scilit:
- Maxillary Sinus Augmentation with Autologous and Heterologous Bone Graft: A Clinical and Radiographic Report of Immediate and Delayed Implant PlacementJournal of Maxillofacial and Oral Surgery, 2013
- Maxillary Sinus Elevation by Lateral Window Approach: Evolution of Technology and TechniqueJournal of Evidence-Based Dental Practice, 2012
- Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: A 3D FEA studyJournal of the Mechanical Behavior of Biomedical Materials, 2011
- A three dimensional finite element study on dental implant designJournal of Genetic Engineering and Biotechnology, 2011
- Elastic properties and apparent density of human edentulous maxilla and mandibleInternational Journal of Oral and Maxillofacial Surgery, 2009
- Application of the finite element method in dental implant researchComputer Methods in Biomechanics and Biomedical Engineering, 2006
- Management of the edentulous patientClinical Oral Implants Research, 2000
- Implant surgery to overcome anatomical difficultiesBritish Dental Journal, 1999
- Finite element analysis of non‐axial versus axial loading of oral implants in the mandible of the dogJournal of Oral Rehabilitation, 1998
- Tissue-Integrated Prostheses. Osseointegration in Clinical DentistryPlastic and Reconstructive Surgery, 1986