Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations
Open Access
- 1 January 2014
- journal article
- research article
- Published by Medknow in Journal of Medical Physics
- Vol. 39 (1) , 10-7
Abstract
High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by 241 Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy -1 for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy -1 achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production.Keywords
This publication has 14 references indexed in Scilit:
- Secondary neutron spectra from modern Varian, Siemens, and Elekta linacs with multileaf collimatorsMedical Physics, 2009
- Neutron measurements in a Varian 2100C LINAC facility using a Bonner sphere system based on passive gold activation detectorsRadiation Protection Dosimetry, 2007
- Investigation of photoneutron dose equivalent from high-energy photons in radiotherapyApplied Radiation and Isotopes, 2007
- On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levelsRadiation Protection Dosimetry, 2006
- Monte Carlo study of Siemens PRIMUS photoneutron productionPhysics in Medicine & Biology, 2005
- Characterisation of neutron fields around high-energy x-ray radiotherapy machinesRadiation Protection Dosimetry, 2004
- Peripheral neutron and gamma doses in radiotherapy with an 18 MV linear acceleratorRadiation Protection Dosimetry, 2004
- Monte Carlo simulation of the photoneutron field in linac radiotherapy treatments with different collimation systemsPhysics in Medicine & Biology, 2004
- Photonuclear dose calculations for high‐energy photon beams from Siemens and Varian linacsMedical Physics, 2003
- Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear acceleratorsJournal of Applied Clinical Medical Physics, 2003