NAS-PPG: PPG-Based Heart Rate Estimation Using Neural Architecture Search
- 13 April 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (13) , 14941-14949
Abstract
It is common for people to use wristband-type electronic devices such as smartwatches for routine healthcare services. Among the healthcare services provided by smartwatches, the method of measuring the heart rate (HR) during exercise is non-invasive and uses a photoplethysmogram (PPG); however, the disadvantage is that it is vulnerable to the motion artifacts (MAs) of the user. A technique for removing an MA from a PPG by using an accelerometer was studied and recently many studies were conducted based on deep learning-based algorithms. In this study, various preprocessing techniques were compared, and optimal preprocessing parameters were determined, and an improvement in the performance was achieved by using a model tuning technique. In addition, the model was optimized with hyperparameter search and neural architecture search using Neural Network Intelligence developed by Microsoft. As a result, the parameter was reduced by 75 times as compared to previous works, and the mean absolute error (MAE) was improved by 26%, from 7.65 BPM to 6.02 BPM.Keywords
Funding Information
- Ministry of Culture, Sports and Tourism and Korea Creative Content Agency (R2019020008)
This publication has 35 references indexed in Scilit:
- A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion ArtifactsIEEE Transactions on Biomedical Engineering, 2015
- Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum ReconstructionIEEE Transactions on Biomedical Engineering, 2015
- TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical ExerciseIEEE Transactions on Biomedical Engineering, 2014
- Comparison of Heart Rate Variability from PPG with That from ECG2014
- A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic BiosensorsIEEE Journal of Biomedical and Health Informatics, 2013
- Artifacts in wearable photoplethysmographs during daily life motions and their reduction with least mean square based active noise cancellation methodComputers in Biology and Medicine, 2012
- Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometryPhysiological Measurement, 2010
- A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjectsJournal of Medical Engineering & Technology, 2009
- Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2007
- Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter2003