Bounded Kalman filter method for motion-robust, non-contact heart rate estimation
- 29 January 2018
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (2) , 873-897
Abstract
The authors of this work present a real-time measurement of heart rate across different lighting conditions and motion categories. This is an advancement over existing remote Photo Plethysmography (rPPG) methods that require a static, controlled environment for heart rate detection, making them impractical for real-world scenarios wherein a patient may be in motion, or remotely connected to a healthcare provider through telehealth technologies. The algorithm aims to minimize motion artifacts such as blurring and noise due to head movements (uniform, random) by employing i) a blur identification and denoising algorithm for each frame and ii) a bounded Kalman filter technique for motion estimation and feature tracking. A case study is presented that demonstrates the feasibility of the algorithm in non-contact estimation of the pulse rate of subjects performing everyday head and body movements. The method in this paper outperforms state of the art rPPG methods in heart rate detection, as revealed by the benchmarked results.Keywords
Funding Information
- National Center for Advancing Translational Sciences (NCATS)
- National Institutes of Health (NIH) (TR000127, TR002014)
- National Science Foundation (NSF) (1527148, 1624727)
This publication has 41 references indexed in Scilit:
- Eulerian video magnification for revealing subtle changes in the worldACM Transactions on Graphics, 2012
- Improved Kalman Filter Method for Measurement Noise Reduction in Multi Sensor RFID SystemsSensors, 2011
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- Robust Real-Time Face DetectionInternational Journal of Computer Vision, 2004
- Heart Rate MonitoringSports Medicine, 2003
- Validation of the Polar Heart Rate Monitor for Assessing Heart Rate During Physical and Mental StressJournal of Psychophysiology, 2000
- Photoplethysmography- fundamental aspects of the optical properties of blood in motionTransactions of the Institute of Measurement and Control, 1982
- Photoelectric plethysmography-some fundamental aspects of the reflection and transmission methodsClinical Physics and Physiological Measurement, 1981
- Determination of Hemoglobin and Its Derivatives1966
- A New Approach to Linear Filtering and Prediction ProblemsJournal of Basic Engineering, 1960