Field Comparison of Active and Passive Soil Gas Sampling Techniques for VOC Monitoring at Contaminated Sites
Authors:
- Raffaella BorrelliRBRaffaella Borrelli
- Alessandra CecconiACAlessandra Cecconi
- Alessandro OldaniAOAlessandro Oldani
- Federico FuinFFFederico Fuin
- Renata EmilianiRERenata Emiliani
- Fabrizio CacciariFCFabrizio Cacciari
- Antonella VecchioAVAntonella Vecchio
- Camilla LanariCLCamilla Lanari
- Federico VillaniFVFederico Villani
- Guido BonfediGBGuido Bonfedi
- Donatella GiacopettiDGDonatella Giacopetti
- Renato BaciocchiRBRenato Baciocchi
Open Access
- 26 April 2025
- journal article
- research article
- Published by MDPI AG in Environments
- Vol. 12 (5) , 141
Abstract
This study presented a comprehensive comparison of soil gas sampling methodologies to monitor volatile organic compounds (VOCs) at two industrial sites in northern Italy. Utilizing active sampling techniques, such as stainless-steel canisters, vacuum bottles, and sorbent tubes, alongside passive methods like low-density polyethylene (PE) membranes, sorbent pens, and Waterloo Membrane Samplers (WMS), the research examines their effectiveness under varied environmental conditions. Five field campaigns were conducted in two areas of the industrial sites characterized by BTEX and chlorinated solvent contamination. The results highlighted that active sampling, while expensive, provides real-time, high-resolution VOC concentration data, often outperforming passive methods for heavier compounds (e.g., hexachlorobutadiene). However, using the active systems in certain campaigns, challenges such as high soil humidity or atmospheric air infiltration were observed, resulting in an underestimation of the soil gas concentrations. Passive sampling systems demonstrated cost-effective, efficient alternatives, offering consistent spatial and temporal coverage. These methods showed alignment with active techniques for lighter compounds (e.g., TCE and BTEX) but faced limitations in sorbent saturation and equilibrium time for heavier VOCs (e.g., hexachlorobutadiene), requiring adjustments in exposure duration to enhance accuracy. PE samplers provided results comparable to active methods, especially for BTEX and TCE, while WMS and sorbent pens exhibited lower sensitivity for certain analytes. This underscores the importance of optimizing sampler configurations and deployment strategies. The findings emphasize the value of integrating active and passive approaches to achieve robust VOC assessments in heterogeneous subsurface environments.Keywords
This publication has 33 references indexed in Scilit:
- Development of an in situ equilibrium polydimethylsiloxane passive sampler for measuring volatile organic compounds in soil vaporChemosphere, 2023
- Performance of passive sampling with low-density polyethylene membranes for the estimation of freely dissolved DDx concentrations in lake environmentsChemosphere, 2018
- Volatile emissions from common consumer productsAir Quality, Atmosphere & Health, 2015
- Applications of polydimethylsiloxane in analytical chemistry: A reviewAnalytica Chimica Acta, 2012
- Polydimethylsiloxane-based permeation passive air sampler. Part I: Calibration constants and their relation to retention indices of the analytesJournal of Chromatography A, 2011
- Polydimethylsiloxane-based permeation passive air sampler. Part II: Effect of temperature and humidity on the calibration constantsJournal of Chromatography A, 2010
- Passive sampling as a tool for obtaining reliable analytical information in environmental quality monitoringAnalytical and Bioanalytical Chemistry, 2009
- Application of passive soil gas technology to determine the source and extent of a PCE groundwater plume in an urban environmentRemediation Journal, 2008
- Passive sampling and/or extraction techniques in environmental analysis: a reviewAnalytical and Bioanalytical Chemistry, 2004
- Passive dosimeters — an approach to atmospheric pollutants analysisScience of The Total Environment, 1984