Label‐Free Biophysical Markers from Whole Blood Microfluidic Immune Profiling Reveal Severe Immune Response Signatures
Abstract
Disease manifestation and severity from acute infections are often due to hyper‐aggressive host immune responses which change within minutes. Current methods for early diagnosis of infections focus on detecting low abundance pathogens, which are time‐consuming, of low sensitivity, and do not reflect the severity of the pathophysiology appropriately. The approach here focuses on profiling the rapidly changing host inflammatory response, which in its over‐exuberant state, leads to sepsis and death. A 15‐min label‐free immune profiling assay from 20 µL of unprocessed blood using unconventional L and Inverse‐L shaped pillars of deterministic lateral displacement microfluidic technology is developed. The hydrodynamic interactions of deformable immune cells enable simultaneous sorting and immune response profiling in whole blood. Preliminary clinical study of 85 donors in emergency department with a spectrum of immune response states from healthy to severe inflammatory response shows correlation with biophysical markers of immune cell size, deformability, distribution, and cell counts. The speed of patient stratification demonstrated here has promising impact in deployable point‐of‐care systems for acute infections triage, risk management, and resource allocation at emergency departments, where clinical manifestation of infection severity may not be clinically evident as compared to inpatients in the wards or intensive care units.Keywords
Funding Information
- University of Edinburgh
- Singapore-MIT Alliance for Research and Technology Centre (ING‐000494‐BIO)
This publication has 45 references indexed in Scilit:
- Temperature response of the neuronal cytoskeleton mapped via atomic force and fluorescence microscopyPhysical Biology, 2013
- Rotational separation of non-spherical bioparticles using I-shaped pillar arrays in a microfluidic deviceNature Communications, 2013
- Getting Leukocytes to the Site of InflammationVeterinary Pathology, 2013
- Hydrodynamic stretching of single cells for large population mechanical phenotypingProceedings of the National Academy of Sciences of the United States of America, 2012
- Cell labeling approaches for fluorescence‐based in vivo flow cytometryCytometry Part A, 2011
- Scaling deterministic lateral displacement arrays for high throughput and dilution-free enrichment of leukocytesJournal of Micromechanics and Microengineering, 2011
- Sizing up the nucleus: nuclear shape, size and nuclear-envelope assemblyJournal of Cell Science, 2009
- Deterministic hydrodynamics: Taking blood apartProceedings of the National Academy of Sciences of the United States of America, 2006
- Temperature-induced sol-gel transition and microgel formation in α-actinin cross-linked actin networks: A rheological studyPhysical Review E, 1996
- Definitions for Sepsis and Organ Failure and Guidelines for the Use of Innovative Therapies in SepsisChest, 1992