Smartphone Technology to Remotely Measure Postural Sway during Double- and Single-Leg Squats in Adults with Femoroacetabular Impingement and Those with No Hip Pain
Authors:
- Charlotte J. MarshallCMCharlotte J. Marshall
- Charlotte GandertonCGCharlotte Ganderton
- Adam FelthamAFAdam Feltham
- Doa El-AnsaryDEDoa El-Ansary
- Adrian PranataAPAdrian Pranata
- John O’donnellJOJohn O’donnell
- Amir TaklaATAmir Takla
- Phong TranPTPhong Tran
- Nilmini WickramasingheNWNilmini Wickramasinghe
- Oren TiroshOren Tirosh
Open Access
Abstract
Background: The COVID-19 pandemic has accelerated the demand for utilising telehealth as a major mode of healthcare delivery, with increasing interest in the use of tele-platforms for remote patient assessment. In this context, the use of smartphone technology to measure squat performance in people with and without femoroacetabular impingement (FAI) syndrome has not been reported yet. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient’s device and measure their squat performance in real time using the smartphone inertial sensors. The aim of this study was to investigate the association and test–retest reliability of the TelePhysio app in measuring postural sway performance during a double-leg (DLS) and single-leg (SLS) squat task. In addition, the study investigated the ability of TelePhysio to detect differences in DLS and SLS performance between people with FAI and without hip pain. Methods: A total of 30 healthy (nfemales = 12) young adults and 10 adults (nfemales = 2) with diagnosed FAI syndrome participated in the study. Healthy participants performed DLS and SLS on force plates in our laboratory, and remotely in their homes using the TelePhysio smartphone application. Sway measurements were compared using the centre of pressure (CoP) and smartphone inertial sensor data. A total of 10 participants with FAI (nfemales = 2) performed the squat assessments remotely. Four sway measurements in each axis (x, y, and z) were computed from the TelePhysio inertial sensors: (1) average acceleration magnitude from the mean (aam), (2) root-mean-square acceleration (rms), (3) range acceleration (r), and (4) approximate entropy (apen), with lower values indicating that the movement is more regular, repetitive, and predictable. Differences in TelePhysio squat sway data were compared between DLS and SLS, and between healthy and FAI adults, using analysis of variance with significance set at 0.05. Results: The TelePhysio aam measurements on the x- and y-axes had significant large correlations with the CoP measurements (r = 0.56 and r = 0.71, respectively). The TelePhysio aam measurements demonstrated moderate to substantial between-session reliability values of 0.73 (95% CI 0.62–0.81), 0.85 (95% CI 0.79–0.91), and 0.73 (95% CI 0.62–0.82) for aamx, aamy, and aamz, respectively. The DLS of the FAI participants showed significantly lower aam and apen values in the medio-lateral direction compared to the healthy DLS, healthy SLS, and FAI SLS groups (aam = 0.13, 0.19, 0.29, and 0.29, respectively; and apen = 0.33, 0.45, 0.52, and 0.48, respectively). In the anterior–posterior direction, healthy DLS showed significantly greater aam values compared to the healthy SLS, FAI DLS, and FAI SLS groups (1.26, 0.61, 0.68, and 0.35, respectively). Conclusions: The TelePhysio app is a valid and reliable method of measuring postural control during DLS and SLS tasks. The application is capable of distinguishing performance levels between DLS and SLS tasks, and between healthy and FAI young adults. The DLS task is sufficient to distinguish the level of performance between healthy and FAI adults. This study validates the use of smartphone technology as a tele-assessment clinical tool for remote squat assessment.Keywords
Funding Information
- early career researcher PhD grants awarded to Charlotte Marshall by the university
This publication has 38 references indexed in Scilit:
- Motor variability in occupational health and performanceClinical Biomechanics, 2012
- Postural sway parameters using a triaxial accelerometer: comparing elderly and young healthy adultsComputer Methods in Biomechanics and Biomedical Engineering, 2012
- Changes in the amount and structure of motor variability during a deboning process are associated with work experience and neck–shoulder discomfortApplied Ergonomics, 2009
- Lower trunk motion and speed-dependence during walkingJournal of NeuroEngineering and Rehabilitation, 2009
- Muscle Strength and Flexibility Characteristics of People Displaying Excessive Medial Knee DisplacementArchives of Physical Medicine and Rehabilitation, 2008
- A Novel Approach to Measure Variability in the Anterior Cruciate Ligament Deficient Knee During Walking: The Use of the Approximate Entropy in OrthopaedicsJournal of Clinical Monitoring and Computing, 2006
- Assessment and Differential Diagnosis of the Painful HipClinical Orthopaedics and Related Research, 2003
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- Common Hip Injuries in SportSports Medicine, 1997
- Human balance and posture control during standing and walkingGait & Posture, 1995