Fast 3D rosette spectroscopic imaging of neocortical abnormalities at 3 T: Assessment of spectral quality
- 14 September 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (5) , 2470-2480
Abstract
Purpose: To use a fast 3D rosette spectroscopic imaging acquisition to quantitatively evaluate how spectral quality influences detection of the endogenous variation of gray and white matter metabolite differences in controls, and demonstrate how rosette spectroscopic imaging can detect metabolic dysfunction in patients with neocortical abnormalities.Methods: Data were acquired on a 3T MR scanner and 32‐channel head coil, with rosette spectroscopic imaging covering a 4‐cm slab of fronto‐parietal‐temporal lobes. The influence of acquisition parameters and filtering on spectral quality and sensitivity to tissue composition was assessed by LCModel analysis, the Cramer‐Rao lower bound, and the standard errors from regression analyses. The optimized protocol was used to generate normative white and gray matter regressions and evaluate three patients with neocortical abnormalities.Results: As a measure of the sensitivity to detect abnormalities, the standard errors of regression for Cr/NAA and Ch/NAA were significantly correlated with the Cramer‐Rao lower bound values (R = 0.89 and 0.92, respectively, both with P < 0.001). The rosette acquisition with a duration of 9.6 min, produces a mean Cramer‐Rao lower bound (%) over the entire slab of 4.6 ± 2.6 and 5.8 ± 2.3 for NAA and Cr, respectively. This enables a Cr/NAA standard error of 0.08 (i.e., detection sensitivity of 25% for a 50/50 mixed gray and white matter voxel). In healthy controls, the regression of Cr/NAA versus fraction gray matter in the cingulate differs from frontal and parietal regions.Conclusions: Fast rosette spectroscopic imaging acquisitions with regression analyses are able to identify metabolic differences across 4‐cm slabs of the brain centrally and over the cortical periphery with high efficiency, generating results that are consistent with clinical findings. Magn Reson Med 79:2470–2480, 2018. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- National Institutes of Health (EB011639, NS090417, NS081772)
This publication has 37 references indexed in Scilit:
- In vivo brain rosette spectroscopic imaging (RSI) with LASER excitation, constant gradient strength readout, and automated LCModel quantification for all voxelsMagnetic Resonance in Medicine, 2015
- Multivendor implementation and comparison of volumetric whole‐brain echo‐planar MR spectroscopic imagingMagnetic Resonance in Medicine, 2014
- Neurologic 3D MR Spectroscopic Imaging with Low-Power Adiabatic Pulses and Fast Spiral AcquisitionRadiology, 2012
- Rosette spectroscopic imaging: Optimal parameters for alias‐free, high sensitivity spectroscopic imagingJournal of Magnetic Resonance Imaging, 2009
- Reducing gradient imperfections for spiral magnetic resonance spectroscopic imagingMagnetic Resonance in Medicine, 2006
- Design of flyback echo‐planar readout gradients for magnetic resonance spectroscopic imagingMagnetic Resonance in Medicine, 2005
- Cramér-Rao Bound Expressions for Parametric Estimation of Overlapping Peaks: Influence of Prior KnowledgeJournal of Magnetic Resonance, 2000
- Volumetric spectroscopic imaging with spiral‐based k‐space trajectoriesMagnetic Resonance in Medicine, 1998
- Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain.Radiology, 1994
- Spatial mapping of the chemical shift in NMRMagnetic Resonance in Medicine, 1984