Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation
Authors:
Open Access
- 28 November 2012
- journal article
- case report
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (3) , 409-413
Abstract
Pacemaker and implantable cardioverter-defibrillator (ICD) leads can cause tricuspid valve regurgitation (TR). Few data are available on the best management of significant TR that develops after pacemaker or ICD implantation and regarding any benefits of right ventricular (RV) lead extraction. We sought to determine the impact of RV lead removal on lead-induced TR. We reviewed all patients between 1 January 2000 and 31 December 2010 at the tertiary care hospital who had a preoperative indication of TR and underwent percutaneous extraction of an RV lead with the intent of trying to correct moderate or severe TR. Pre- and post-procedure echoes and clinical data were retrospectively reviewed. In the four patients identified, the RV lead was removed and placed in the coronary sinus to try to improve moderate or severe TR due to lead impingement. There was no significant improvement in the degree of TR except one patient where TR improved slightly from moderate to mild–moderate. All patients had a dilated tricuspid valve annulus by the time of lead extraction. Tricuspid annulus dilatation appeared to account for the persistent TR after RV lead removal. A greater degree of tricuspid valve annulus dilatation may be a marker and mechanism for irreversible lead-induced TR. Further studies are needed to determine whether surgical tricuspid valve repair or replacement combined with RV lead extraction would result in better outcomes than a percutaneous lead extraction approach.Keywords
This publication has 10 references indexed in Scilit:
- Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrodeEuropean Heart Journal - Cardiovascular Imaging, 2010
- Incidence, Risk Factors, and Outcome of Traumatic Tricuspid Regurgitation After Percutaneous Ventricular Lead RemovalJACC, 2009
- Functional Tricuspid Regurgitation in Patients With Pulmonary HypertensionChest, 2009
- The Effect of Transvenous Pacemaker and Implantable Cardioverter Defibrillator Lead Placement on Tricuspid Valve Function: An Observational StudyJournal of the American Society of Echocardiography, 2008
- An unusual cause of pacemaker-induced severe tricuspid regurgitationEuropean Heart Journal - Cardiovascular Imaging, 2008
- Clinical Utility of 3-Dimensional Echocardiography in the Evaluation of Tricuspid Regurgitation Caused by Pacemaker LeadsCirculation Journal, 2008
- Impact of transvenous ventricular pacing leads on tricuspid regurgitation in pediatric and congenital heart disease patientsJournal of Interventional Cardiac Electrophysiology, 2007
- Entrapment of Permanent Pacemaker Lead as the Cause of Tricuspid Regurgitation Role of 3-Dimensional EchocardiographyCirculation Journal, 2007
- Severe Symptomatic Tricuspid Valve Regurgitation Due to Permanent Pacemaker or Implantable Cardioverter-Defibrillator LeadsJACC, 2005
- Improvement in Right Ventricular Systolic Function After Surgical Correction of Isolated Tricuspid RegurgitationJournal of the American Society of Echocardiography, 2000