Enhanced osseointegration of dental implants with reduced graphene oxide coating
Open Access
- 21 March 2022
- journal article
- research article
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 26 (1) , 1-16
Abstract
Background: The implants of pure titanium (Ti) and its alloys can lead to implant failure because of their poor interaction with bone-associated cells during bone regeneration. Surface modification over implants has achieved successful implants for enhanced osseointegration. Herein, we report a robust strategy to implement bioactive surface modification for implant interface enabled by the combinatorial system of reduced graphene oxide (rGO)-coated sandblasted, large-grit, and acid-etched (SLA) Ti to impart benefits to the implant. Methods: We prepared SLA Ti (ST) implants with different surface modifications [i.e., rGO and recombinant human bone morphogenetic protein-2 (rhBMP-2)] and investigated their dental tissue regenerating ability in animal models. We performed comparative studies in surface property, in vitro cellular behaviors, and in vivo osseointegration activity among different groups, including ST (control), rhBMP-2-immobilized ST (BI-ST), rhBMP-2-treated ST (BT-ST), and rGO-coated ST (R-ST). Results: Spectroscopic, diffractometric, and microscopic analyses confirmed that rGO was coated well around the surfaces of Ti discs (for cell study) and implant fixtures (for animal study). Furthermore, in vitro and in vivo studies revealed that the R-ST group showed significantly better effects in cell attachment and proliferation, alkaline phosphatase activity, matrix mineralization, expression of osteogenesis-related genes and protein, and osseointegration than the control (ST), BI-ST, and BT-ST groups. Conclusion: Hence, we suggest that the rGO-coated Ti can be a promising candidate for the application to dental or even orthopedic implants due to its ability to accelerate the healing rate with the high potential of osseointegration.Keywords
All Related Versions
Funding Information
- National Research Foundation of Korea (2021R1A2C2006013)
- Korea Evaluation Institute of Industrial Technology (20002010 and 20014399)
This publication has 52 references indexed in Scilit:
- Physical stability of arginine-glycine-aspartic acid peptide coated on anodized implants after installationThe Journal of Advanced Prosthodontics, 2013
- Increasing the antioxidant activity of green tea polyphenols in the presence of iron for the reduction of graphene oxideCarbon, 2012
- Graphene based materials: Past, present and futureProgress in Materials Science, 2011
- Relationship between surface properties (roughness, wettability and morphology) of titanium and dental implant removal torqueJournal of the Mechanical Behavior of Biomedical Materials, 2008
- Surface treatments of titanium dental implants for rapid osseointegrationDental Materials, 2007
- In vivo effects of coating loaded and unloaded Ti implants with collagen, chondroitin sulfate, and hydroxyapatite in the sheep tibiaJournal of Orthopaedic Research, 2007
- Bone formation at rhBMP‐2‐coated titanium implants in the rat ectopic modelJournal of Clinical Periodontology, 2007
- The structure and regulation of vinculinTrends in Cell Biology, 2006
- Understanding and controlling the bone–implant interfaceBiomaterials, 1999
- Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit.Clinical Oral Implants Research, 1997