Comparison of Different Electrocardiography with Vectorcardiography Transformations
Open Access
Abstract
This paper deals with transformations from electrocardiographic (ECG) to vectorcardiographic (VCG) leads. VCG provides better sensitivity, for example for the detection of myocardial infarction, ischemia, and hypertrophy. However, in clinical practice, measurement of VCG is not usually used because it requires additional electrodes placed on the patient’s body. Instead, mathematical transformations are used for deriving VCG from 12-leads ECG. In this work, Kors quasi-orthogonal transformation, inverse Dower transformation, Kors regression transformation, and linear regression-based transformations for deriving P wave (PLSV) and QRS complex (QLSV) are implemented and compared. These transformation methods were not yet compared before, so we have selected them for this paper. Transformation methods were compared for the data from the Physikalisch-Technische Bundesanstalt (PTB) database and their accuracy was evaluated using a mean squared error (MSE) and a correlation coefficient (R) between the derived and directly measured Frank’s leads. Based on the statistical analysis, Kors regression transformation was significantly more accurate for the derivation of the X and Y leads than the others. For the Z lead, there were no statistically significant differences in the medians between Kors regression transformation and the PLSV and QLSV methods. This paper thoroughly compared multiple VCG transformation methods to conventional VCG Frank’s orthogonal lead system, used in clinical practice.Keywords
Funding Information
- Ministry of Education of the Czech Republic (Project No. SP2019/85 and SP2019/118)
- European Regional Development Fund in the Research Centre of Advanced Mechatronic Systems project (project number CZ.02.1.01/0.0/0.0/16_019/0000867)
- European Regional Development Fund in A Research Platform focused on Industry 4.0 and Robotics in Ostrava project (CZ.02.1.01/0.0/0.0/17_049/0008425)
This publication has 44 references indexed in Scilit:
- High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST SegmentISRN Cardiology, 2012
- Signals and Signal Processing for the ElectrophysiologistCirculation: Arrhythmia and Electrophysiology, 2011
- Signals and Signal Processing for the ElectrophysiologistCirculation: Arrhythmia and Electrophysiology, 2011
- When deriving the spatial QRS-T angle from the 12-lead electrocardiogram, which transform is more Frank: regression or inverse Dower?Journal of Electrocardiology, 2010
- Limitations of Dower's Inverse Transform for the Study of Atrial Loops during Atrial FibrillationPacing and Clinical Electrophysiology, 2009
- The SVEC III vectorcardiographic lead systemIEEE Engineering in Medicine and Biology Magazine, 2004
- Requirements for a cocitation similarity measure, with special reference to Pearson's correlation coefficientJournal of the American Society for Information Science and Technology, 2003
- Experimental comparison of “parallel grid leads” with simple bipolar, and the SVEC-III, Frank, and McFee-Parungao systems. I. Sagittal leadsAmerican Heart Journal, 1964
- An orthogonal lead system for clinical electrocardiographyAmerican Heart Journal, 1961
- COMPARISON OF DIFFERENT SYSTEMS OF VECTORCARDIOGRAPHYHeart, 1952