High peak capacity separation of peptides through the serial connection of LC shell‐packed columns
- 9 April 2009
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 32 (8) , 1129-1136
Abstract
High peak capacity was obtained for the separation of a HSA tryptic digest through the serial connection of three LC columns packed with shell material (C18, 15 cm×4.6 mm, 2.7 μm particle size). A major benefit of these particles, consisting of a 1.7 μm solid core and a 0.5 μm porous shell, is the small diffusion path, which reduces axial dispersion of solutes and minimizes peak broadening allowing for higher resolving power to be obtained. Increase in the temperature decreases the viscosity and the backpressure on the columns and in this way allowed to couple multiple columns. Single and multicolumn systems were first evaluated for the separation of a standard sample mixture in the isocratic mode; afterwards three columns could be coupled at 60°C, generating more than 90 000 effective plates (200 000 plates/meter) for the separation of HSA in gradient mode on a conventional HPLC instrument. Peak capacity ratios were found in good accordance with the theoretical gain in resolution, i.e. values of 1.37 and 1.67 were measured, when doubling and tripling the length of stationary phases, respectively (the highest measured peak capacity on three coupled columns was 367).Keywords
This publication has 21 references indexed in Scilit:
- Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest possible timeJournal of Chromatography A, 2008
- Comparative study of the performance of columns packed with several new fine silica particles: Would the external roughness of the particles affect column properties?Journal of Chromatography A, 2007
- Gradient elution separation and peak capacity of columns packed with porous shell particlesJournal of Chromatography A, 2007
- Comparison between the efficiencies of columns packed with fully and partially porous C18-bonded silica materialsJournal of Chromatography A, 2007
- Mass-Transfer Kinetics in a Shell Packing Material for ChromatographyAnalytical Chemistry, 2007
- High-efficiency liquid chromatography on conventional columns and instrumentation by using temperature as a variable: I. Experiments with 25cm×4.6mm I.D., 5μm ODS columnsJournal of Chromatography A, 2006
- A column capacity study of single, serial, and parallel linked rod monolithic high performance liquid chromatography columnsJournal of Chromatography A, 2005
- High temperature liquid chromatography on packed capillary columns with nonaqueous mobile phasesJournal of Microcolumn Separations, 1995
- The role of the temperature in reversed-phase high-performance liquid chromatography using pyrocarbon-containing adsorbentsJournal of Chromatography A, 1978
- Enthalpy—entropy compensation in reversed-phase chromatographyJournal of Chromatography A, 1978