4D radial coronary artery imaging within a single breath‐hold: Cine angiography with phase‐sensitive fat suppression (CAPS)
Authors:
- 7 September 2005
- journal article
- clinical trial
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (4) , 833-840
Abstract
Coronary artery data acquisition with steady‐state free precession (SSFP) is typically performed in a single frame in mid‐diastole with a spectrally selective pulse to suppress epicardial fat signal. Data are acquired while the signal approaches steady state, which may lead to artifacts from the SSFP transient response. To avoid sensitivity to cardiac motion, an accurate trigger delay and data acquisition window must be determined. Cine data acquisition is an alternative approach for resolving these limitations. However, it is challenging to use conventional fat saturation with cine imaging because it interrupts the steady‐state condition. The purpose of this study was to develop a 4D coronary artery imaging technique, termed “cine angiography with phase‐sensitive fat suppression” (CAPS), that would result in high temporal and spatial resolution simultaneously. A 3D radial stacked k‐space was acquired over the entire cardiac cycle and then interleaved with a sliding window. Sensitivity‐encoded (SENSE) reconstruction with rescaling was developed to reduce streak artifact and noise. Phase‐sensitive SSFP was employed for fat suppression using phase detection. Experimental studies were performed on volunteers. The proposed technique provides high‐resolution coronary artery imaging for all cardiac phases, and allows multiple images at mid‐diastole to be averaged, thus enhancing the signal‐to‐noise ratio (SNR) and vessel delineation. Magn Reson Med, 2005.Keywords
This publication has 19 references indexed in Scilit:
- Sensitivity‐encoded coronary MRA at 3TMagnetic Resonance in Medicine, 2004
- Feasibility and performance of breath-hold 3D true-FISP coronary MRA using self-calibrating parallel acquisitionMagnetic Resonance in Medicine, 2004
- Coronary MRA with 3D undersampled projection reconstruction TrueFISPMagnetic Resonance in Medicine, 2002
- Real‐time interactive coronary MRAMagnetic Resonance in Medicine, 2001
- 3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteriesMagnetic Resonance in Medicine, 2001
- Superiority of prone position in free-breathing 3D coronary MRA in patients with coronary diseaseJournal of Magnetic Resonance Imaging, 2001
- Coronary angiography by real-time MRI with adaptive averagingMagnetic Resonance in Medicine, 2000
- Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiographyJACC, 1999
- Fast Spiral Coronary Artery ImagingMagnetic Resonance in Medicine, 1992
- Coronary arteries: breath-hold MR angiography.Radiology, 1991