Three-wavelength technique for the measurement of oxygen saturation in arterial blood and in venous blood
- 1 January 2009
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 14 (2) , 024046-024046-6
Abstract
Pulse oximetry is an optical technique for the assessment of oxygen saturation in arterial blood and is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and on two-wavelength photoplethysmographic (PPG) measurement of arterial blood volume increase during systole. The technique requires experimental calibration for the determination of the relationship between PPG-derived parameters and arterial oxygen saturation, and this calibration is a source of error in the method. We suggest a three-wavelength PPG technique for the measurement of arterial oxygen saturation that has no need for calibration if the three wavelengths are properly selected in the near-infrared region. The suggested technique can also be implemented for the assessment of venous oxygen saturation by measuring the decrease in transmission of light through a tissue after increasing its blood volume by venous occlusion. The oxygen saturation in venous blood is a parameter that is related to oxygen consumption in tissue and to tissue blood flow. The three-wavelength method has the potential to provide accurate oxygen saturation measurements in arterial and venous blood, but experimental validation of the theory is still required to confirm this claim.Keywords
This publication has 18 references indexed in Scilit:
- The measurement of oxygen saturation in arterial and venous bloodIEEE Instrumentation & Measurement Magazine, 2008
- Effects of assuming constant optical scattering on measurements of muscle oxygenation by near-infrared spectroscopy during exerciseJournal of Applied Physiology, 2007
- Pulse oximetry in the oesophagusPhysiological Measurement, 2005
- Measurement of oxygen saturation in venous blood by dynamic near infrared spectroscopyJournal of Biomedical Optics, 2000
- Fiber Optic Sensor for the Measurement of Respiratory Chest Circumference ChangesJournal of Biomedical Optics, 1999
- Light Absorbance in Pulse Oximetry1997
- Calibration1997
- Estimation of optical pathlength through tissue from direct time of flight measurementPhysics in Medicine & Biology, 1988
- Noninvasive pulse oximetry utilizing skin reflectance photoplethysmographyIEEE Transactions on Biomedical Engineering, 1988
- Spectrophotometric monitoring of arterial oxygen saturation in the fingertipMedical & Biological Engineering & Computing, 1980