Bacteriuria and phenotypic antimicrobial susceptibility testing in 45 min by point-of-care Sysmex PA-100 System: first clinical evaluation
Open Access
- 3 June 2024
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 43 (8) , 1533-1543
Abstract
Purpose: This study compared the results of the new Sysmex PA-100 AST System, a point-of-care analyser, with routine microbiology for the detection of urinary tract infections (UTI) and performance of antimicrobial susceptibility tests (AST) directly from urine. Methods: Native urine samples from 278 female patients with suspected uncomplicated UTI were tested in the Sysmex PA-100 and with reference methods of routine microbiology: urine culture for bacteriuria and disc diffusion for AST. Results: The analyser delivered bacteriuria results in 15 min and AST results within 45 min. Sensitivity and specificity for detection of microbiologically confirmed bacteriuria were 84.0% (89/106; 95% CI: 75.6–90.4%) and 99.4% (155/156; 95% CI: 96.5–100%), respectively, for bacterial species within the analyser specifications. These are Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis, Enterococcus faecalis and Staphylococcus saprophyticus, which are common species causing uncomplicated UTI. Overall categorical agreement (OCA) for AST results for the five antimicrobials tested in the Sysmex PA-100 (amoxicillin/clavulanic acid, ciprofloxacin, fosfomycin, nitrofurantoin and trimethoprim) ranged from 85.4% (70/82; 95%CI: 75.9–92.2%) for ciprofloxacin to 96.4% (81/84; 95% CI: 89.9–99.3%) for trimethoprim. The Sysmex PA-100 provided an optimal treatment recommendation in 218/278 cases (78.4%), against 162/278 (58.3%) of clinical decisions. Conclusion: This first clinical evaluation of the Sysmex PA-100 in a near-patient setting demonstrated that the analyser delivers phenotypic AST results within 45 min, which could enable rapid initiation of the correct targeted treatment with no further adjustment needed. The Sysmex PA-100 has the potential to significantly reduce ineffective or unnecessary antibiotic prescription in patients with UTI symptoms.Keywords
Funding Information
- Sysmex Corporation
This publication has 16 references indexed in Scilit:
- A review on urinary tract infections diagnostic methods: Laboratory-based and point-of-care approachesJournal of Pharmaceutical and Biomedical Analysis, 2022
- Rapid Diagnostics for Antibiotic Resistance: Urgent Need for Strong Clinical EvidenceClinical Infectious Diseases, 2022
- Global, regional, and national burden of urinary tract infections from 1990 to 2019: an analysis of the global burden of disease study 2019World Journal of Urology, 2022
- Rapid Susceptibility Testing MethodsClinics In Laboratory Medicine, 2019
- New and developing diagnostic technologies for urinary tract infectionsNature Reviews Urology, 2017
- Microfluidic advances in phenotypic antibiotic susceptibility testingBiomedical Microdevices, 2016
- Microfluidic techniques for high throughput single cell analysisCurrent Opinion in Biotechnology, 2016
- Research highlights: microfluidic analysis of antimicrobial susceptibilityLab on a Chip, 2015
- Statistics in medical journals: some recent trendsStatistics in Medicine, 2000
- Detection of Antimicrobial Activity in Urine for Epidemiologic Studies of Antibiotic UseJournal of Clinical Epidemiology, 1999