The Proximal Femur Nail Antirotation: An Identifiable Improvement in the Treatment of Unstable Pertrochanteric Fractures?
Authors:
- Michiel J. M. SegersMSMichiel J. M. Segers
- Rogier K. J. SimmermacherRSRogier K. J. Simmermacher
- Eric R. HammacherEHEric R. Hammacher
- 1 July 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 71 (1) , 169-174
Abstract
The optimal surgical treatment of patients with an unstable extracapsular proximal femoral fracture is yet to be found. From the biomechanical point of view, the use of an intramedullary device in combination with a dynamic femoral head/neck stabilization implant seems an optimal technique. One of these intramedullary devices, the Proximal Femoral Nail (PFN), has several drawbacks in practice. The Proximal Femur Nail Antirotation (PFNA) has been designed to address these. We hypothesized that the placement of one femoral head/neck fixation device in the PFNA would improve positioning of the implant in the femoral head compared with the PFN and reduce the number of reoperations in both short and long term. We followed 157 consecutive patients with unstable trochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31.A.2 and A.3) treated with a PFN or a PFNA for 1 year. The radiologic position of the implant was evaluated, and the postoperative local and systemic complications were registered. The position of the femoral head/neck stabilization implant was "good" in 39 (44.8%) patients in the PFN group and 23 (32.9%) patients in the PFNA group; the position was "acceptable" in 30 (34.5%) versus 33 (47.1%) patients, and in 18 (20.7%) versus 14 (20%) patients, the position was "poor" (p = 0.277). Because of implant-related complications, three patients in the PFN group and four patients in the PFNA group needed an early reoperation (p = 0.136). A late reoperation because of implant-related complications was performed in 13 patients in the PFN group and in three in the PFNA group (p = 0.016). This study shows that osteosynthesis with the PFNA does not improve the position of the implant in the femoral head compared with the PFN. However, the risk of a secondary complication and the necessity of a late reoperation are significantly higher in patients treated with a PFN compared with patients treated with a PFNA.Keywords
This publication has 6 references indexed in Scilit:
- The new proximal femoral nail antirotation (PFNA®) in daily practice: Results of a multicentre clinical studyInjury, 2008
- Proximal Femoral Nail for Treatment of Trochanteric Femoral FracturesJournal of Orthopaedic Surgery, 2007
- Pitfalls and complications in the use of the proximal femoral nailLangenbeck's Archives of Surgery, 2004
- The AO/ASIF proximal femoral nail (PFN) for the treatment of unstable trochanteric femoral fractureInjury, 2002
- The treatment of unstable, extracapsular hip fractures with the AO/ASIF proximal femoral nail (PFN)—our first 60 casesInjury, 2002
- The AO/ASIF-proximal femoral nail (PFN): a new device for the treatment of unstable proximal femoral fracturesInjury, 1999