    Double‐bowtie filter design for pediatric spectral CT imaging: A fan beam simulation study

    by Yinglin Ge, Olivia F. Sandvold, Roland Proksa, Amy E. Perkins, Thomas Koehler, Kevin M. Brown, Yannan Jin, Heiner Daerr, Ravindra M. Manjeshwar, Peter B. Noël

    Background: Despite concerns about radiation dose in pediatric patients, computed tomography (CT) remains a first‐line imaging modality for children. Spectral CT provides additional diagnostic information that benefits pediatric imaging. However, most existing spectral CT systems are primarily optimized for adult patients. Purpose: To develop and evaluate a novel double bowtie filter integrating a K‐edge material layer with a conventional Teflon filter for CT. The proposed design aims to enhance spectral signal‐to‐noise ratio (SNR) and spectral separation within the projection domain while maintaining radiation dose levels suitable for pediatric imaging. Methods: A simulation framework was developed and used to model a rapid kVp‐switching CT system operating at 70/110 kVp with realistic tube power and geometric constraints. Pediatric phantoms of three sizes (100–200 mm anterior–posterior width) were used to evaluate performance. Five accessible and safe filter materials—gadolinium (Gd), holmium (Ho), erbium (Er), silver (Ag), and tin (Sn)—were tested in combination with a Teflon bowtie. System performance was quantified using virtual monoenergetic image (VMI) SNR at 40 and 70 keV, and the area under the monoenergetic SNR curve (AUMC) as a comprehensive spectral image quality metric. Dose consistency was ensured using a traditional Teflon bowtie as the reference. Results: The Teflon + Gd configuration achieved the highest performance, improving mean AUMC over all fan angles by 53.6% on average and up to 56% for the largest phantom. VMI SNR increased by approximately 46% at 40 keV and 42% at 70 keV. Conclusions: The double‐bowtie concept substantially enhances spectral performance. The Teflon + Gd design provides a manufacturable, pediatric‐optimized solution adaptable to kVp‐switching and other spectral CT architectures, offering improved diagnostic quality at low dose levels.

  • Open Access

    Enhancing the Motion Robustness of Breath‐Held 3D T1 ‐Weighted Abdominal MRI Using a Cartesian Acquisition With Spiral Profile Ordering

    by Alice Scudeletti, Jonathan Stelter, Kilian Weiss, Lisa Steinhelfer, Robert L. Walter, Rickmer F. Braren, Dimitrios C. Karampinos

    Purpose: To develop and validate a novel self‐gated motion‐robust 3D T1‐weighted gradient echo imaging framework based on a Cartesian acquisition with spiral profile ordering (CASPR) for abdominal imaging under unstable breath‐hold conditions. Methods: The CASPR trajectory was evaluated using frequency encoding in the anterior‐to‐posterior (AP) direction for respiratory motion robustness. The CASPR's intrinsic k‐space center oversampling was exploited to directly extract a self‐gated respiratory signal from the acquired data. A soft‐gating motion compensation framework was integrated into the reconstruction pipeline. The method was validated in 10 healthy volunteers (five males and five females) and compared to a Cartesian acquisition with pseudorandom undersampling. Results: Both CASPR and Cartesian acquisition with pseudorandom undersampling exhibited motion artifacts under unstable breath‐hold conditions without retrospective correction. The proposed self‐gated CASPR framework enabled reliable extraction of the respiratory signal directly from the AP readout. Soft gating significantly improved the image quality of motion‐corrupted scans. Conclusion: This study introduces a novel self‐gated CASPR‐based framework for respiratory motion compensation in 3D abdominal MRI, in cases of incomplete and delayed breath‐holds. The method enables the extraction of the self‐navigator signal along the anterior‐to‐posterior axis and compensates for motion using a soft‐gating technique.

  • Open Access

    Deep‐Reorder: Refined Motion Correction for 3D Brain MRI via Iterative Data Regrouping

    by Laurens Beljaards, Matthias J. P. van Osch, Martijn Nagtegaal, Jochen Keupp, Chinmay Rao, Nicola Pezzotti, Mariya Doneva, Marius Staring

    Purpose: Accurate and temporally high‐resolution estimation of subject motion is paramount for effective motion‐correction in MRI . This work proposes a novel approach for estimating subject motion within a 3D MRI scan with high temporal resolution. Methods: Starting from an incoherent sampling scheme, images are reconstructed from temporally ordered k‐space fractions via deep learning, enabling motion estimation via registration between each image. Assuming the bulk of the motion is removed using these initial estimates, the remaining misalignment between k‐space fractions is expected to be minimally correlated in time. Based on this insight, an iterative strategy is proposed in which shots are arbitrarily regrouped into new k‐space fractions, regardless of their original temporal ordering, for subsequent motion estimation and correction. This effectively increases the temporal resolution of the approach, enabling individual correction of all shots. Results: When applied to 3D T1w TFE MRI of the brain, the proposed approach “Deep‐Reorder” estimated a unique motion state for all shots, producing significantly better estimations of retrospective motion compared to estimation without iterative data regrouping. On prospectively motion‐corrupted scans with intentional head movement by volunteers, the proposed approach consistently improved image quality, producing less noisy images with reduced motion artifacts. Conclusion: In conclusion, the proposed approach, which is free of external tracking devices or navigators, effectively estimated 3D motion and corrected motion artifacts with increased temporal resolution.

  • Open Access

    Designing for Centralized Healthcare: A Socio-Technical Case Study of Pancreatic Cancer Diagnosis and AI Integration

    by Nick Ruijs, Jon Pluyter, Lin-Lin Chen, Mathias Funk

    Pancreatic cancer remains one of the deadliest malignancies, with outcomes dependent on timely diagnosis and accurate assessment of surgical resectability. Centralized care models aim to improve diagnostic quality by concentrating specialized expertise. While centralization improves access to expertise, it introduces new challenges in coordinating diagnostic work across institutions, aligning heterogeneous data and technologies, and sustaining reliable collective decision-making under time pressure. How diagnostic reasoning is practically accomplished within these distributed care networks remains insufficiently understood. We conducted a qualitative case study of a regional centralized pancreatic cancer care network in the Netherlands. Drawing on socio-technical systems theory, we analyzed diagnostic workflows including imaging assessments, multidisciplinary team meetings, and surgical procedures through contextual observations. Our findings show that diagnostic reliability emerges from the coordinated interaction of distributed expertise, clinical data, and technological infrastructures. Multidisciplinary meetings, shared imaging systems, and iterative data interpretation play a central role, while tensions arise around efficiency, standardization, authority, and uncertainty. This study contributes (1) empirical insight into the socio-technical dynamics of centralized pancreatic cancer care, (2) a qualitative approach for studying complex, distributed healthcare systems, and (3) practice-grounded implications for integrating AI in ways that support existing clinical coordination and expertise.


  • Open Access

    Cardiac MRI at 3.0T in the presence of implantable cardioverter defibrillators (ICDs)

    by T. Reiter, O.M. Weber, I. Weiss, N. A. Kraus, M. Walther, S. Kress, W. R. Bauer

    Patients with implantable cardioverter-defibrillators (ICDs) often are excluded from receiving CMR scans at 3.0T due to ICD-induced image artifacts. This work aims to transfer sequence protocols established for CMR imaging in the presence of ICDs at 1.5T to a first human application at 3.0T. All measurements were performed on a clinical 3T MRI scanner. Phantom measurements were used to establish and optimize wideband PSIR LGE imaging at 3.0T. Volunteer measurements with externally placed ICDs were used for optimization of CINE imaging and wideband PSIR imaging. Thirdly, patients with implanted ICD were examined with the optimized protocols. Human measurements showed that SA stacks obtained with spoiled GRE after contrast agent showed a markedly lower artifact burden than the conventional approach. For scar imaging, a wideband PSIR with a bandwidth of 3kHz and a frequency offset of +750Hz allowed a sufficient suppression of relevant artifacts in the majority of scans. No strong correlation between the image quality and the distance between the cardiac silhouette and the device was detected. The presented work shows the feasibility of clinical cardiac MRI at 3.0T including GRE-CINE and wideband PSIR-LGE for patients with ICDs.

  • Open Access

    Regional strain patterns in patients with mitral valve prolapse

    by Jeffrey Ji-Peng Li, Shing Ching, Annette Aigner, Frank Edelmann, Stefanie Maria Werhahn, Rebecca Beyer, Jeanette Schulz-Menger, Jennifer Erley, Misael Estepa, Cyrill Meuwly, et al.

    Purpose: Echocardiographic studies have shown that patients with mitral valve prolapse (MVP) exhibit altered regional contraction patterns. With cardiovascular magnetic resonance (CMR) becoming increasingly important in the evaluation of global and regional cardiac function, we aimed to quantify the regional contraction patterns of patients with MVP using CMR feature tracking (FT) strain analysis in comparison to a control group. Methods: Of all patients who underwent CMR scans from 2013 to 2022 at our institution, 132 patients with MVP were identified and compared to 50 controls without any cardiac condition. CMR scans were performed on 1.5-T and 3-T scanners, and CMR-FT strain analysis was performed on cine images using MEDIS QStrain 4.1. The primary endpoints were regional peak left ventricular (LV) longitudinal strain values. Secondary endpoints included LV global circumferential strain (GCS) and global longitudinal strain (GLS) and left atrial (LA) reservoir strain and right ventricular (RV) free wall longitudinal strain. Differences between groups were assessed using linear regression models, adjusting for age and sex. Results: Patients with MVP showed worse regional peak longitudinal strain compared to controls in the basal and part of the medial LV segments, especially in segments S1, S4, S6, S7, and S12. In contrast, the apical segments S13, S14, S15, and S16 showed better strain values. Additionally, LA reservoir strain was reduced in MVP patients. LV GCS, LV GLS, and RV free wall longitudinal strain were similar between both groups. Conclusion: While patients with MVP showed preserved LV GCS and GLS compared to controls, LV regional longitudinal strain analysis showed impaired strain in the basal segments and increased strain in the apical segments.

  • Open Access

    The Prognostic Value of Paramagnetic Rim Lesions in People With Multiple Sclerosis

    by Markus Lauerer, Cui Ci Voon, Julian McGinnis, Dominik Sepp, Jakob Meineke, Tun Wiltgen, Ronja C. Berg, Christine Preibisch, Benedikt Wiestler, Christina Engl, et al.

    Background and ObjectivesParamagnetic rim lesions (PRLs) have been established as a radiologic surrogate for chronic active inflammation in multiple sclerosis (MS). Although associations between PR...

  • Open Access

    Assessment of emphysema with simulated low-dose dark-field radiography

    by Henriette Bast, Rafael C. Schick, Thomas Koehler, Florian T. Gassert, Alexander W. Marka, Andreas P. Sauter, Bernhard Renger, Gregor Zimmermann, Marcus R. Makowski, Franz Pfeiffer, et al.

    Objective: Dark-field radiography allows the visualization of lung tissue changes associated with pulmonary emphysema. Simulations were used to investigate the impact of radiation dose reduction on the diagnostic accuracy of emphysema detection. Materials and methods: Dark-field and attenuation chest radiographs acquired during an ongoing clinical study were used to simulate multiple low-dose counterparts corresponding to median effective doses between 7 and 18 µSv. All study participants had undergone a medically indicated chest computed tomography scan that showed either pulmonary emphysema or no lung pathologies. In a randomized reader study, three radiologists independently assessed the simulated low-dose dark-field and attenuation radiographs as well as the original images for the presence of emphysema. The area under the curves (AUC) of the receiver operating characteristics (ROC) were analyzed using Obuchowski’s method. ROC curves were also generated by using different values of the dark-field coefficient to differentiate between absent and at least mild emphysema. Results: The original (full-dose) images and simulated low-dose images of 93 participants (57 males, 36 females) were included, with participants’ median age of 66 years (interquartile range 54 to 73 years). The radiologists’ ROC curves of the simulated low-dose images at 11 µSv (AUC = 0.84) did not differ significantly ( p  = 0.177) from the full-dose curve (AUC = 0.86). For all dose levels, the dark-field coefficient could distinguish between absent and at least mild emphysema with an AUC of 0.85. Conclusion: Radiation dose reduction in dark-field imaging for emphysema assessment might be feasible, with median effective doses potentially as low as 11 µSv. Key Points: Question How does radiation dose reduction affect the diagnostic potential of dark-field chest radiographs? Findings For actual, regular-dose (36 µSv) dark-field radiographs, AUC was 0.86, and 0.84 for simulated low-dose images. Down to 7 µSv, the dark-field coefficient AUC was 0.85. Relevance statement Simulations suggest that the radiation dose in dark-field chest imaging could be lowered to 11 µSv, indicating the technique’s potential for ultra-low-dose imaging, which could be especially beneficial for potential clinical screening applications in the future.

  • Open Access

    AI-Assisted Compressed Sensing for Optimized Inner Ear Imaging: a Multi-Rater MRI Evaluation of CSAI T2-DRIVE

    by Enrike Rosenkranz, Jennifer Köhler, Nora M. Weiss, Martin Renz, Laura Leukert, Kilian Weiss, Barbara Wollenberg, Dennis M. Hedderich, Jan S. Kirschke, Wilhelm Wimmer, et al.

    Purpose: High-resolution T2-weighted imaging is essential for preoperative assessment before cochlear implantation. Compressed sensing (CS) with AI-based reconstruction (CSAI) reduces acquisition times whilst preserving image quality. Although CSAI has been established in various clinical applications, its performance in inner ear imaging remains unclear. This study assesses CSAI-optimized T2-DRIVE sequences at different resolutions and acquisition times for visualizing inner ear structures. Methods: In 30 healthy participants, CS T2-DRIVE was acquired at isotropic resolutions of 0.65, 0.5, and 0.4 mm. 0.5 and 0.4 mm datasets were also reconstructed using a commercially available AI-based reconstruction algorithm. Three raters independently assessed the imaging quality of anatomical landmarks (cochlea, semicircular canals, vestibulocochlear nerve), artifacts, and signal-to-noise ratio (SNR) using a 5-point Likert scale. Each rater re-rated a subset of images after ≥ 4 weeks. Inter- and intra-rater reliability were calculated using quadratically weighted Cohen’s kappa, and differences between sequences were analyzed using cumulative link mixed models (CLMM). Results: 0.4 mm isotropic imaging exhibited lower SNR compared to CSAI 0.5 mm, regardless of reconstruction algorithm ( p < 0.001). Across all raters, CSAI T2 at 0.5 mm resolution significantly improved delineation of the cochlea and vestibulocochlear nerve compared to 0.65 mm imaging ( p < 0.001), while assessability of semicircular canals was reduced ( p = 0.082). Acquisition times increased with higher resolutions (0.65/0.5/0.4 mm: 4:02/4:25/4:34 min). Conclusion: AI-driven reconstruction algorithms enable statistically significant improvements in imaging of key inner-ear structures with minimal increases in scan time at 0.5 mm resolution.