Boston Scientific (United States)

Types
Company, FunderLocations
Marlborough, United StatesLatest Publications
- 19 November 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Expired endoscopic devices: separating inventory management from shelf-life validation
- 19 November 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Expired endoscopic devices: separating inventory management from shelf-life validation
- 11 November 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
One‐Year Outcomes of Pulmonary Vein Isolation With a Novel Cryoballoon in Asian Population
Background: Cryoballoon ablations for pulmonary vein isolation (PVI) to treat atrial fibrillation (AF) are well established. The POLAR SMART study was designed to collect prospective real‐world data on acute and 12‐month safety and effectiveness of the POLARx cryoballoon for de novo PVI. Methods: POLAR SMART is a prospective, non‐randomized, multicenter study (NCT05282823) with patients enrolled across 19 centers (Japan and South Korea) and followed up to 12 months. Results: AF ablation was performed in 293 patients, 181 receiving only PVI. In the PVI‐only cohort, acute PVI was achieved in 95.0% of patients, and 98.2% of pulmonary veins (PV) with the cryoballoon. Procedure time and fluoroscopy time were 75 ± 25 min and 18.5 ± 11.1 min, respectively. Time to isolation was 42 ± 32 s, with nadir temperature of −56.6 ± 6.9°C. The study met the primary safety endpoint with an event‐free rate of 97.3%. The study effectiveness event‐free rate at 12 months was 75.6% for entire cohort and 81.1% for PVI‐only cohort (POLARx, n = 116; 79.3% and POLARx FIT, n = 65; 84.4%). AF recurrence in PVI‐only cohort was 7.2% for POLARx and 6.2% for POLARx FIT. Ablation procedure increased heart rate (HR) significantly for entire cohort ( p < 0.001). The optimal HR value at predischarge for 12‐month outcome was calculated with 70 bpm (Predicted Probability 0.83). The effect of increased HR remained stable after 12 months for patients ablated with POLARx FIT. Conclusions: The POLARx and POLARx FIT cryoballoon systems are safe and effective for PVI in real‐world use. POLARx FIT ablation was associated with a sustained HR increase over 12 months.
- 11 November 2026
- Published by Wiley in Pacing and Clinical Electrophysiology
One‐Year Outcomes of Pulmonary Vein Isolation With a Novel Cryoballoon in Asian Population
Background: Cryoballoon ablations for pulmonary vein isolation (PVI) to treat atrial fibrillation (AF) are well established. The POLAR SMART study was designed to collect prospective real‐world data on acute and 12‐month safety and effectiveness of the POLARx cryoballoon for de novo PVI. Methods: POLAR SMART is a prospective, non‐randomized, multicenter study (NCT05282823) with patients enrolled across 19 centers (Japan and South Korea) and followed up to 12 months. Results: AF ablation was performed in 293 patients, 181 receiving only PVI. In the PVI‐only cohort, acute PVI was achieved in 95.0% of patients, and 98.2% of pulmonary veins (PV) with the cryoballoon. Procedure time and fluoroscopy time were 75 ± 25 min and 18.5 ± 11.1 min, respectively. Time to isolation was 42 ± 32 s, with nadir temperature of −56.6 ± 6.9°C. The study met the primary safety endpoint with an event‐free rate of 97.3%. The study effectiveness event‐free rate at 12 months was 75.6% for entire cohort and 81.1% for PVI‐only cohort (POLARx, n = 116; 79.3% and POLARx FIT, n = 65; 84.4%). AF recurrence in PVI‐only cohort was 7.2% for POLARx and 6.2% for POLARx FIT. Ablation procedure increased heart rate (HR) significantly for entire cohort ( p < 0.001). The optimal HR value at predischarge for 12‐month outcome was calculated with 70 bpm (Predicted Probability 0.83). The effect of increased HR remained stable after 12 months for patients ablated with POLARx FIT. Conclusions: The POLARx and POLARx FIT cryoballoon systems are safe and effective for PVI in real‐world use. POLARx FIT ablation was associated with a sustained HR increase over 12 months.
- 2 November 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (Suppl_1)
Abstract 18443: Longitudinal Assessment of Focal Pulsed Field Ablation Lesion Volume in a Swine Model Using LGE-MRI
Background: Pulsed field ablation (PFA) creates non-thermal myocardial injury. While chronic lesion dimensions are determined by energy dose, the temporal evolution of focal PFA lesion dimensions remains incompletely characterized. Objective: To quantify longitudinal changes in focal PFA lesion volume using LGE-MRI. Methods: In a swine model, 27 ventricular lesions were created using a focal FARAPOINT™ catheter with a FARASTAR generator. Lesions were assessed with serial 3 Tesla LGE-MRI at four time points: acutely (2-4 hours post-ablation), 2 weeks, 1 month, and 2 months post-ablation. Lesion volumes were segmented using semi-automated CorView software with the GrowCut tool and three segmentation thresholds: Conservative, Moderate, and Aggressive. Moderate segmentation was used as the primary analysis, with Conservative and Aggressive segmentations used as sensitivity analyses. Paired t-tests compared lesion volume between consecutive imaging timepoints. Results: In the Moderate segmentation, mean lesion volume decreased from 0.55±0.41 cm 3 acutely to 0.20±0.15 cm 3 at 2 weeks, representing a 63.6% reduction ( p=0.0017 ). There was no differences from 2 weeks to 1 month, 0.20±0.15 to 0.23±0.16 cm 3 ( p=0.562 ), or from 1 month to 2 months, 0.23±0.16 to 0.22±0.15 cm 3 ( p=0.796 ). Findings were consistent across sensitivity analyses: Conservative volumes decreased from 0.32±0.28 to 0.10±0.08 cm 3 from acute imaging to 2 weeks ( p=0.0035 ), and Aggressive volumes decreased from 0.71±0.49 to 0.29±0.21 cm 3 ( p=0.0015 ), with no significant subsequent changes from 2 weeks to 1 month or from 1 month to 2 months. Conclusion: Serial LGE-MRI demonstrates substantial early changes in LGE-defined lesion volume within the first two weeks following focal PFA, with relative stability thereafter through 2 months. These findings could reflect changes in contrast kinetics over time, recovery of an edemic response, or represent underlying structural changes such as recovery of the PFA reversible zone.
- 2 November 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (Suppl_1)
Abstract 18443: Longitudinal Assessment of Focal Pulsed Field Ablation Lesion Volume in a Swine Model Using LGE-MRI
Background: Pulsed field ablation (PFA) creates non-thermal myocardial injury. While chronic lesion dimensions are determined by energy dose, the temporal evolution of focal PFA lesion dimensions remains incompletely characterized. Objective: To quantify longitudinal changes in focal PFA lesion volume using LGE-MRI. Methods: In a swine model, 27 ventricular lesions were created using a focal FARAPOINT™ catheter with a FARASTAR generator. Lesions were assessed with serial 3 Tesla LGE-MRI at four time points: acutely (2-4 hours post-ablation), 2 weeks, 1 month, and 2 months post-ablation. Lesion volumes were segmented using semi-automated CorView software with the GrowCut tool and three segmentation thresholds: Conservative, Moderate, and Aggressive. Moderate segmentation was used as the primary analysis, with Conservative and Aggressive segmentations used as sensitivity analyses. Paired t-tests compared lesion volume between consecutive imaging timepoints. Results: In the Moderate segmentation, mean lesion volume decreased from 0.55±0.41 cm 3 acutely to 0.20±0.15 cm 3 at 2 weeks, representing a 63.6% reduction ( p=0.0017 ). There was no differences from 2 weeks to 1 month, 0.20±0.15 to 0.23±0.16 cm 3 ( p=0.562 ), or from 1 month to 2 months, 0.23±0.16 to 0.22±0.15 cm 3 ( p=0.796 ). Findings were consistent across sensitivity analyses: Conservative volumes decreased from 0.32±0.28 to 0.10±0.08 cm 3 from acute imaging to 2 weeks ( p=0.0035 ), and Aggressive volumes decreased from 0.71±0.49 to 0.29±0.21 cm 3 ( p=0.0015 ), with no significant subsequent changes from 2 weeks to 1 month or from 1 month to 2 months. Conclusion: Serial LGE-MRI demonstrates substantial early changes in LGE-defined lesion volume within the first two weeks following focal PFA, with relative stability thereafter through 2 months. These findings could reflect changes in contrast kinetics over time, recovery of an edemic response, or represent underlying structural changes such as recovery of the PFA reversible zone.
- 2 November 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (Suppl_1)
Abstract 10641: Weekend versus Weekday Presentation and Outcomes Following Catheter-Directed Therapy for Acute Pulmonary Embolism: A National Electronic Health Record Analysis
Introduction: Delayed treatment escalation during weekends have been reported across acute cardiovascular conditions with variable impact on outcomes. This may be especially relevant for pulmonary embolism (PE), where multidisciplinary coordination and escalation to catheter-directed therapies (CDT) may be required. Whether weekend presentation is associated with worse outcomes among patients with acute PE referred for CDT remains uncertain. Methods: A retrospective cohort study was performed within Truveta, a multi-health system electronic health record (EHR) dataset (2018-2024), including patients receiving CDT for acute PE. Weekend status was defined by day/time of presentation (Friday 5PM - Monday 7AM and holidays). The primary endpoint was in-hospital mortality. Secondary endpoints included in-hospital cardiac arrest, mechanical ventilation (MV), vasopressor use, mechanical circulatory support (MCS), rescue surgical embolectomy, composite bail-out therapy (composite of vasopressor use, need for MCS, MV, surgical embolectomy), International Society of Thrombosis and Haemostasis (ISTH) major bleeding, and intensive care unit (ICU) length of stay (LOS). Multivariable logistic regression was used for binary outcomes and log-linear models for ICU LOS. Results: The cohort included 15,167 patients (weekday n=10,180; weekend n=4,987). The mean age of the total cohort was 62 years, and included 47% females. In-hospital mortality occurred in 417/10,180 (4.10%) weekday vs 236/4,987 (4.73%) weekend patients; weekend presentation was associated with higher adjusted odds of mortality (aOR 1.22, 95% CI 1.02-1.45; p=0.026). Weekend presentation was also associated with higher odds of decompensation: mechanical ventilation (0.65% vs 1.26%; aOR 1.98, 95% CI 1.37-2.86; pConclusion: In a multi-health system EHR cohort of patients receiving advanced catheter-directed PE therapy, weekend presentation was associated with higher adjusted odds of in-hospital mortality and substantially greater need for rescue-level support, without increased major bleeding. These findings suggest weekend vulnerability in treated PE may manifest through acute physiologic decompensation and ICU resource utilization, supporting efforts to optimize PE care pathways.
- 2 November 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (Suppl_1)
Abstract 10641: Weekend versus Weekday Presentation and Outcomes Following Catheter-Directed Therapy for Acute Pulmonary Embolism: A National Electronic Health Record Analysis
Introduction: Delayed treatment escalation during weekends have been reported across acute cardiovascular conditions with variable impact on outcomes. This may be especially relevant for pulmonary embolism (PE), where multidisciplinary coordination and escalation to catheter-directed therapies (CDT) may be required. Whether weekend presentation is associated with worse outcomes among patients with acute PE referred for CDT remains uncertain. Methods: A retrospective cohort study was performed within Truveta, a multi-health system electronic health record (EHR) dataset (2018-2024), including patients receiving CDT for acute PE. Weekend status was defined by day/time of presentation (Friday 5PM - Monday 7AM and holidays). The primary endpoint was in-hospital mortality. Secondary endpoints included in-hospital cardiac arrest, mechanical ventilation (MV), vasopressor use, mechanical circulatory support (MCS), rescue surgical embolectomy, composite bail-out therapy (composite of vasopressor use, need for MCS, MV, surgical embolectomy), International Society of Thrombosis and Haemostasis (ISTH) major bleeding, and intensive care unit (ICU) length of stay (LOS). Multivariable logistic regression was used for binary outcomes and log-linear models for ICU LOS. Results: The cohort included 15,167 patients (weekday n=10,180; weekend n=4,987). The mean age of the total cohort was 62 years, and included 47% females. In-hospital mortality occurred in 417/10,180 (4.10%) weekday vs 236/4,987 (4.73%) weekend patients; weekend presentation was associated with higher adjusted odds of mortality (aOR 1.22, 95% CI 1.02-1.45; p=0.026). Weekend presentation was also associated with higher odds of decompensation: mechanical ventilation (0.65% vs 1.26%; aOR 1.98, 95% CI 1.37-2.86; pConclusion: In a multi-health system EHR cohort of patients receiving advanced catheter-directed PE therapy, weekend presentation was associated with higher adjusted odds of in-hospital mortality and substantially greater need for rescue-level support, without increased major bleeding. These findings suggest weekend vulnerability in treated PE may manifest through acute physiologic decompensation and ICU resource utilization, supporting efforts to optimize PE care pathways.
- 1 November 2026
- Published by Oxford University Press (OUP) in Neuro-Oncology
- Vol. 28 (Supplement)
CTNI-38 Intra-arterial delivery of Yttrium-90 glass microspheres in recurrent glioblastoma (rGBM): early results from the FRONTIER trial
Background: Neurovascular radiotherapy (NVRT) represents a novel intra-arterial approach, utilizing glass yttrium-90 (Y-90) microspheres (TheraSphere™, Boston Scientific) to super-selectively deliver high-dose radiation to tumors. The FRONTIER trial (IDE) evaluates safety and feasibility of this endovascular approach for rGBM. Methods: FRONTIER is a prospective, single-arm, multi-center phase-1 study in rGBM patients with 1-5cm diameter enhancing disease who received ≤two prior lines of therapy. The primary endpoint is 30-day treatment-related Limiting Toxicity incidence (primarily ≥grade 3 non-hematologic toxicities, with additional exclusions). Secondary endpoints include adverse event (AE) rate, neurological changes, technical success (PET absorbed dose within ±20% of target), and efficacy. Perfused volume (PV), defined via angiography-MRI fusion to cover the recurrent lesion, was targeted with 40±4Gy. Eligible patients returned within 14 days for angiography and Y-90 microspheres administration, followed by MRI, Y90-PET, neurological assessments, and clinical surveillance until discharge. Monthly follow-up, including MRI, was required for 6 months, then per site standards. Results: We report the preliminary results of the first 18 subjects treated of the ongoing trial. All tolerated the procedure well, no treatment-related limiting toxicities, and 17/18 patients discharged within 36h. Treatment-related AEs occurred in 11 patients (61%), including n = 2 procedure-related Gr3 events (thromboembolic event [SAE], aPTT prolongation) and n = 3 further SAEs (≤Gr2 muscular weakness, seizure [n = 2]). Transient increase in NIHSS occurred in 8/18 patients and resolved by 1-month in 7/8. Median time-to-next-line therapy was 4.1 months (95%CI 2.7-9.0). Median survival was 13.1 months (95%CI 5.8-15.6). Technical success was 94%. Post-treatment Y90-PET showed median PV absorbed dose of 41.2Gy (range 29.0-45.9Gy). Due to preferential tumor perfusion, median tumor absorbed dose was higher; 124.2Gy (range 53.0-508.5Gy). No symptomatic radiation necrosis was observed during follow-up. Conclusion: Across four institutions, intra-arterial Y-90 microsphere administration was technically feasible and well-tolerated. NVRT delivers very high absorbed doses to a prespecified target volume.
- 1 November 2026
- Published by Oxford University Press (OUP) in Neuro-Oncology
- Vol. 28 (Supplement)
CTNI-38 Intra-arterial delivery of Yttrium-90 glass microspheres in recurrent glioblastoma (rGBM): early results from the FRONTIER trial
Background: Neurovascular radiotherapy (NVRT) represents a novel intra-arterial approach, utilizing glass yttrium-90 (Y-90) microspheres (TheraSphere™, Boston Scientific) to super-selectively deliver high-dose radiation to tumors. The FRONTIER trial (IDE) evaluates safety and feasibility of this endovascular approach for rGBM. Methods: FRONTIER is a prospective, single-arm, multi-center phase-1 study in rGBM patients with 1-5cm diameter enhancing disease who received ≤two prior lines of therapy. The primary endpoint is 30-day treatment-related Limiting Toxicity incidence (primarily ≥grade 3 non-hematologic toxicities, with additional exclusions). Secondary endpoints include adverse event (AE) rate, neurological changes, technical success (PET absorbed dose within ±20% of target), and efficacy. Perfused volume (PV), defined via angiography-MRI fusion to cover the recurrent lesion, was targeted with 40±4Gy. Eligible patients returned within 14 days for angiography and Y-90 microspheres administration, followed by MRI, Y90-PET, neurological assessments, and clinical surveillance until discharge. Monthly follow-up, including MRI, was required for 6 months, then per site standards. Results: We report the preliminary results of the first 18 subjects treated of the ongoing trial. All tolerated the procedure well, no treatment-related limiting toxicities, and 17/18 patients discharged within 36h. Treatment-related AEs occurred in 11 patients (61%), including n = 2 procedure-related Gr3 events (thromboembolic event [SAE], aPTT prolongation) and n = 3 further SAEs (≤Gr2 muscular weakness, seizure [n = 2]). Transient increase in NIHSS occurred in 8/18 patients and resolved by 1-month in 7/8. Median time-to-next-line therapy was 4.1 months (95%CI 2.7-9.0). Median survival was 13.1 months (95%CI 5.8-15.6). Technical success was 94%. Post-treatment Y90-PET showed median PV absorbed dose of 41.2Gy (range 29.0-45.9Gy). Due to preferential tumor perfusion, median tumor absorbed dose was higher; 124.2Gy (range 53.0-508.5Gy). No symptomatic radiation necrosis was observed during follow-up. Conclusion: Across four institutions, intra-arterial Y-90 microsphere administration was technically feasible and well-tolerated. NVRT delivers very high absorbed doses to a prespecified target volume.
- Open Access
- 1 November 2026
- Published by Becaris Publishing Limited in Journal of Comparative Effectiveness Research
- Vol. 15 (11)
Comparative cost analysis of Eluvia™ versus Zilver ® PTX ® in treating femoropopliteal peripheral artery disease utilizing real-world data
Aim: To compare the hospital-based costs among patients with femoropopliteal artery (FPA) disease treated with Eluvia™ versus Zilver ® PTX ® drug-eluting stents using a large real-world USA hospital database. Materials & methods: This retrospective study included adults in the Premier Healthcare Database who underwent lower extremity FPA endovascular revascularization with Eluvia or Zilver PTX between 1 April 2019 and 31 March 2022. Total hospital-based costs during the index procedure and cumulative 1- and 2-year post-discharge follow-up were compared using multivariable generalized linear models adjusted for age, sex, race and baseline chronic limb-threatening ischemia (CLTI) status. Prespecified subgroup analyses were conducted by care setting (hospital inpatient and hospital outpatient) and among patients with chronic kidney disease (CKD) and CLTI. Results: A total of 7208 patients were included, comprising 4218 treated with Eluvia and 2990 treated with Zilver PTX. Patients treated with Eluvia had a higher prevalence of several comorbidities, including congestive heart failure and CKD. Unadjusted mean hospital-based index procedure costs were similar between groups (Eluvia, $28,631 vs Zilver PTX, $28,359; difference, -$272; p = 0.7233). After adjustment, mean index procedure hospital-based costs did not differ significantly between treatment groups ($30,031, p = 0.8491). However, Eluvia was associated with lower adjusted cumulative hospital-based costs at the 1-year (difference, $4,017; p = 0.0066) and 2-year (difference, $6250; p = 0.0021) follow-up. Similar associations were observed in the hospital inpatient and CKD subgroups, whereas no statistically significant differences were observed in the CLTI subgroup. Conclusion: Across patients undergoing femoropopliteal endovascular revascularization, Eluvia was associated with significantly lower post-discharge cumulative hospital-based follow-up costs than Zilver PTX while index procedure costs were comparable. These findings reflect hospital-based costs captured within participating hospitals and do not include medication costs or costs of care received outside the Premier Healthcare Database; therefore, they should not be interpreted as total healthcare costs.
- 1 November 2026
- Published by Becaris Publishing Limited in Journal of Comparative Effectiveness Research
- Vol. 15 (11)
Open AccessComparative cost analysis of Eluvia™ versus Zilver ® PTX ® in treating femoropopliteal peripheral artery disease utilizing real-world data
Aim: To compare the hospital-based costs among patients with femoropopliteal artery (FPA) disease treated with Eluvia™ versus Zilver ® PTX ® drug-eluting stents using a large real-world USA hospital database. Materials & methods: This retrospective study included adults in the Premier Healthcare Database who underwent lower extremity FPA endovascular revascularization with Eluvia or Zilver PTX between 1 April 2019 and 31 March 2022. Total hospital-based costs during the index procedure and cumulative 1- and 2-year post-discharge follow-up were compared using multivariable generalized linear models adjusted for age, sex, race and baseline chronic limb-threatening ischemia (CLTI) status. Prespecified subgroup analyses were conducted by care setting (hospital inpatient and hospital outpatient) and among patients with chronic kidney disease (CKD) and CLTI. Results: A total of 7208 patients were included, comprising 4218 treated with Eluvia and 2990 treated with Zilver PTX. Patients treated with Eluvia had a higher prevalence of several comorbidities, including congestive heart failure and CKD. Unadjusted mean hospital-based index procedure costs were similar between groups (Eluvia, $28,631 vs Zilver PTX, $28,359; difference, -$272; p = 0.7233). After adjustment, mean index procedure hospital-based costs did not differ significantly between treatment groups ($30,031, p = 0.8491). However, Eluvia was associated with lower adjusted cumulative hospital-based costs at the 1-year (difference, $4,017; p = 0.0066) and 2-year (difference, $6250; p = 0.0021) follow-up. Similar associations were observed in the hospital inpatient and CKD subgroups, whereas no statistically significant differences were observed in the CLTI subgroup. Conclusion: Across patients undergoing femoropopliteal endovascular revascularization, Eluvia was associated with significantly lower post-discharge cumulative hospital-based follow-up costs than Zilver PTX while index procedure costs were comparable. These findings reflect hospital-based costs captured within participating hospitals and do not include medication costs or costs of care received outside the Premier Healthcare Database; therefore, they should not be interpreted as total healthcare costs.
- Open Access
- 1 November 2026
- Published by Becaris Publishing Limited in Journal of Comparative Effectiveness Research
- Vol. 15 (11)
Development and implementation of a living network meta-analysis framework for comparative effectiveness research: a case study in chronic venous insufficiency treatment
Aim: To develop, implement and evaluate a living network meta-analysis (NMA) framework for comparative effectiveness research, using chronic venous insufficiency treatment as a case study. The framework addresses key barriers to sustained evidence synthesis: resource sustainability, methodological consistency and transparent dissemination. Materials & methods: A four-phase living NMA framework was established with prospective protocol registration, quarterly literature surveillance and annual update cycles. The baseline systematic review, registered in PROSPERO, searched English-language publications (2000–2023) per PRISMA guidelines. Eligible studies included randomized and non-randomized comparisons of polidocanol 1% endovenous microfoam (PEM) or endovenous thermal ablation versus any comparator. Network connectivity relied on common comparators (surgery, physician-compounded foam) and head-to-head PEM versus endovenous thermal ablation studies. The protocol specifies predetermined eligibility criteria, standardized data extraction and consistent statistical methods, with results posted to a publicly accessible website. Results: The baseline NMA (13 studies; 233,801 patients) was published in a peer-reviewed journal and simultaneously posted publicly. The first update identified seven new eligible studies, expanding the evidence base to 20 studies and 235,093 patients. Effect estimates remained stable with no change in primary conclusions, demonstrating robustness to new evidence incorporation. Update-cycle workload was substantially less than the initial NMA effort, with efficiency gains attributable to team continuity, accrued clinical expertise and stable data definitions. Conclusion: This living NMA framework balances scientific rigor with practical sustainability through industry partnership and transparent dissemination. The successful first update confirms feasibility, though the framework was developed with a single sponsor in one clinical area and transferability to other contexts has not been tested.
- 1 November 2026
- Published by Becaris Publishing Limited in Journal of Comparative Effectiveness Research
- Vol. 15 (11)
Open AccessDevelopment and implementation of a living network meta-analysis framework for comparative effectiveness research: a case study in chronic venous insufficiency treatment
Aim: To develop, implement and evaluate a living network meta-analysis (NMA) framework for comparative effectiveness research, using chronic venous insufficiency treatment as a case study. The framework addresses key barriers to sustained evidence synthesis: resource sustainability, methodological consistency and transparent dissemination. Materials & methods: A four-phase living NMA framework was established with prospective protocol registration, quarterly literature surveillance and annual update cycles. The baseline systematic review, registered in PROSPERO, searched English-language publications (2000–2023) per PRISMA guidelines. Eligible studies included randomized and non-randomized comparisons of polidocanol 1% endovenous microfoam (PEM) or endovenous thermal ablation versus any comparator. Network connectivity relied on common comparators (surgery, physician-compounded foam) and head-to-head PEM versus endovenous thermal ablation studies. The protocol specifies predetermined eligibility criteria, standardized data extraction and consistent statistical methods, with results posted to a publicly accessible website. Results: The baseline NMA (13 studies; 233,801 patients) was published in a peer-reviewed journal and simultaneously posted publicly. The first update identified seven new eligible studies, expanding the evidence base to 20 studies and 235,093 patients. Effect estimates remained stable with no change in primary conclusions, demonstrating robustness to new evidence incorporation. Update-cycle workload was substantially less than the initial NMA effort, with efficiency gains attributable to team continuity, accrued clinical expertise and stable data definitions. Conclusion: This living NMA framework balances scientific rigor with practical sustainability through industry partnership and transparent dissemination. The successful first update confirms feasibility, though the framework was developed with a single sponsor in one clinical area and transferability to other contexts has not been tested.
- Open Access
- 26 October 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (20) , 2710-2722
Safety and Effectiveness of a Novel Laser-Based Intravascular Lithotripsy System for Coronary Calcium
- 26 October 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (20) , 2710-2722
Open AccessSafety and Effectiveness of a Novel Laser-Based Intravascular Lithotripsy System for Coronary Calcium
- 26 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (Supplement)
Mortality and device intervention in patients with a history of atrial fibrillation: a substudy of APPRAISE ATP
Background/Introduction: Atrial fibrillation (AF) has previously been found to be associated with an increased occurrence of ventricular tachyarrhythmias. AF may also negatively impact all-cause mortality and cause inappropriate device interventions. APPRAISE ATP was a large, randomized trial assessing the efficacy of antitachycardia pacing (ATP) as a first-line strategy for the termination of fast ventricular tachycardias. Purpose: To assess outcomes in patients with AF at baseline from the APPRAISE ATP clinical trial cohort and evaluate the occurrence of appropriate and inappropriate implantable cardioverter defibrillator (ICD) interventions, as well as the association between AF and all-cause death. Methods: APPRAISE ATP (N=2595) was a prospective trial with high-rate programming (VT zone: 200-249 bpm, VF zone: 250+ bpm) and long delays to therapy (12s in the VT zone). All patients with ECG data at baseline (N=1933) were grouped by whether they had a history of AF at enrolment, had AF by ECG at implant, or had no history of AF. Kaplan-Meier methodology was then used to determine incidence of time to first all-cause shock, time to first appropriate shock, time to first inappropriate shock, time to death, or time to death or shock from any cause. Results: Of the patients with ECG data at baseline, 234 had AF by ECG at implant (10 had AF noted in their medical history), 289 had a history of AF, and 1410 had no history of AF. At 60 months from randomization, the incidence of all-cause shock was 28.1% for patients with AF at implant, 23.8% for patients with a history of AF, and 13.8% for patients with no history of AF (Log-rank P=<.001; Figure). Similarly, first appropriate shock was 17.2%, 18.7%, and 11.4% (Log-rank P=.008) and first inappropriate shock was 14.7%, 8.5%, and 3.2% (Log-rank P=<.001), for each group respectively. Mortality was significantly associated with history of AF, with an incidence of 22.1% for patients with AF at implant, 24.8% for patients with a history of AF, and 17.0% for patients with no history of AF (Log-rank P=0.048; Figure). For the outcome of time to first shock or death, the incidence was 42.8%, 41.2%, and 26.3% (Log-rank P=<.001), respectively. Conclusions: Our analysis of the APPRAISE ATP cohort found an association between AF at baseline and outcome during long-term follow up, in terms of treatable ventricular tachyarrhythmias and mortality. These findings suggest that AF at baseline characterizes patients at higher risk. Further analyses are planned to assess the outcome implications of device-detected AF and of new onset AF in this cohort.Figure 1Figure 2
- 26 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (Supplement)
Mortality and device intervention in patients with a history of atrial fibrillation: a substudy of APPRAISE ATP
Background/Introduction: Atrial fibrillation (AF) has previously been found to be associated with an increased occurrence of ventricular tachyarrhythmias. AF may also negatively impact all-cause mortality and cause inappropriate device interventions. APPRAISE ATP was a large, randomized trial assessing the efficacy of antitachycardia pacing (ATP) as a first-line strategy for the termination of fast ventricular tachycardias. Purpose: To assess outcomes in patients with AF at baseline from the APPRAISE ATP clinical trial cohort and evaluate the occurrence of appropriate and inappropriate implantable cardioverter defibrillator (ICD) interventions, as well as the association between AF and all-cause death. Methods: APPRAISE ATP (N=2595) was a prospective trial with high-rate programming (VT zone: 200-249 bpm, VF zone: 250+ bpm) and long delays to therapy (12s in the VT zone). All patients with ECG data at baseline (N=1933) were grouped by whether they had a history of AF at enrolment, had AF by ECG at implant, or had no history of AF. Kaplan-Meier methodology was then used to determine incidence of time to first all-cause shock, time to first appropriate shock, time to first inappropriate shock, time to death, or time to death or shock from any cause. Results: Of the patients with ECG data at baseline, 234 had AF by ECG at implant (10 had AF noted in their medical history), 289 had a history of AF, and 1410 had no history of AF. At 60 months from randomization, the incidence of all-cause shock was 28.1% for patients with AF at implant, 23.8% for patients with a history of AF, and 13.8% for patients with no history of AF (Log-rank P=<.001; Figure). Similarly, first appropriate shock was 17.2%, 18.7%, and 11.4% (Log-rank P=.008) and first inappropriate shock was 14.7%, 8.5%, and 3.2% (Log-rank P=<.001), for each group respectively. Mortality was significantly associated with history of AF, with an incidence of 22.1% for patients with AF at implant, 24.8% for patients with a history of AF, and 17.0% for patients with no history of AF (Log-rank P=0.048; Figure). For the outcome of time to first shock or death, the incidence was 42.8%, 41.2%, and 26.3% (Log-rank P=<.001), respectively. Conclusions: Our analysis of the APPRAISE ATP cohort found an association between AF at baseline and outcome during long-term follow up, in terms of treatable ventricular tachyarrhythmias and mortality. These findings suggest that AF at baseline characterizes patients at higher risk. Further analyses are planned to assess the outcome implications of device-detected AF and of new onset AF in this cohort.Figure 1Figure 2
- 26 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (Supplement)
Early clinical experience with single-catheter map-and-ablate pentaspline PFA workflows in Europe: findings from the OPALISE Sub-Study of the FARAVERSE Registry
Background: Pulsed field ablation (PFA) is an established non-thermal energy modality for the treatment of atrial fibrillation (AF). As clinical adoption expands, focus has shifted toward workflow efficiency and procedural precision, including accurate lesion delivery and consistent tissue contact. Technologies that integrate electroanatomical mapping (EAM) and PFA within a single catheter enable streamlined map-and-ablate workflows and may reduce procedure time, radiation exposure and reliance on adjunctive imaging modalities. Although feasibility has been demonstrated, real-world European data utilizing the second-generation mapping-integrated pentaspline PFA catheter remains limited. Purpose: To characterize procedural metrics and early safety outcomes associated with adoption of an integrated map-and-ablate PFA workflow in routine clinical practice across the European Union. Methods: OPALISE is a prospective, observational sub-protocol of the FARAVERSE global registry enrolling up to 550 patients treated with a second-generation mapping-integrated pentaspline PFA catheter. Consecutive patients undergoing AF ablation were included, with procedures performed according to local standard practice. Procedural characteristics and acute safety outcomes were analyzed, including a predefined sub-analysis of de novo and redo cases. Results: At submission, 346 patients were enrolled (mean age 65.0±11.5 years; 34.3% female; 56.9% paroxysmal AF), including 78.9% de novo and 21.1% redo cases. A map-and-ablate workflow was more frequently used in de novo versus redo cases (74.3% vs. 52.1%; p<0.01) and was associated with shorter mapping times (6±6 vs. 9±10 minutes; p=0.01). Pulmonary vein isolation (PVI)-only strategies predominated in de novo cases (57.0% vs. 25.4%; p<0.01), whereas PVI-plus approaches were more common in redo procedures (74.6% vs. 43.0%; p<0.01). De novo cases resulted in more PV PFA lesions (53±23 vs. 44±21; p=0.02), with no differences in the total number of non-PV lesions. Despite greater substrate modification in redo cases, overall efficiency was maintained, with similar procedure duration (57±24 vs. 61±26 minutes; p=0.30), left atrial dwell time (35±18 vs. 36±17 minutes; p=0.99), fluoroscopy time (12±7 vs. 11±6 minutes; p=0.29). Acute procedural success was comparable between cohorts. No device-related coronary spasm, transient ischemic attack, or phrenic nerve injury have been reported. Enrollment and monitoring are ongoing, complete acute procedural and safety data will be available at presentation. Conclusions: In this prospective European registry, early adoption of an integrated EAM-guided PFA workflow was associated with consistent procedural efficiency in both de novo and redo AF ablation. These findings demonstrate that the second-generation mapping-integrated pentaspline PFA catheter supports implementation of map-and-ablate strategies across diverse European practice settings.
- 26 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (Supplement)
Early clinical experience with single-catheter map-and-ablate pentaspline PFA workflows in Europe: findings from the OPALISE Sub-Study of the FARAVERSE Registry
Background: Pulsed field ablation (PFA) is an established non-thermal energy modality for the treatment of atrial fibrillation (AF). As clinical adoption expands, focus has shifted toward workflow efficiency and procedural precision, including accurate lesion delivery and consistent tissue contact. Technologies that integrate electroanatomical mapping (EAM) and PFA within a single catheter enable streamlined map-and-ablate workflows and may reduce procedure time, radiation exposure and reliance on adjunctive imaging modalities. Although feasibility has been demonstrated, real-world European data utilizing the second-generation mapping-integrated pentaspline PFA catheter remains limited. Purpose: To characterize procedural metrics and early safety outcomes associated with adoption of an integrated map-and-ablate PFA workflow in routine clinical practice across the European Union. Methods: OPALISE is a prospective, observational sub-protocol of the FARAVERSE global registry enrolling up to 550 patients treated with a second-generation mapping-integrated pentaspline PFA catheter. Consecutive patients undergoing AF ablation were included, with procedures performed according to local standard practice. Procedural characteristics and acute safety outcomes were analyzed, including a predefined sub-analysis of de novo and redo cases. Results: At submission, 346 patients were enrolled (mean age 65.0±11.5 years; 34.3% female; 56.9% paroxysmal AF), including 78.9% de novo and 21.1% redo cases. A map-and-ablate workflow was more frequently used in de novo versus redo cases (74.3% vs. 52.1%; p<0.01) and was associated with shorter mapping times (6±6 vs. 9±10 minutes; p=0.01). Pulmonary vein isolation (PVI)-only strategies predominated in de novo cases (57.0% vs. 25.4%; p<0.01), whereas PVI-plus approaches were more common in redo procedures (74.6% vs. 43.0%; p<0.01). De novo cases resulted in more PV PFA lesions (53±23 vs. 44±21; p=0.02), with no differences in the total number of non-PV lesions. Despite greater substrate modification in redo cases, overall efficiency was maintained, with similar procedure duration (57±24 vs. 61±26 minutes; p=0.30), left atrial dwell time (35±18 vs. 36±17 minutes; p=0.99), fluoroscopy time (12±7 vs. 11±6 minutes; p=0.29). Acute procedural success was comparable between cohorts. No device-related coronary spasm, transient ischemic attack, or phrenic nerve injury have been reported. Enrollment and monitoring are ongoing, complete acute procedural and safety data will be available at presentation. Conclusions: In this prospective European registry, early adoption of an integrated EAM-guided PFA workflow was associated with consistent procedural efficiency in both de novo and redo AF ablation. These findings demonstrate that the second-generation mapping-integrated pentaspline PFA catheter supports implementation of map-and-ablate strategies across diverse European practice settings.