LabCorp (United States)

Type
CompanyLocations
Burlington, United StatesRelationships
Latest Publications
- 4 November 2026
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 166 (5)
Laboratory stewardship of qualitative JAK2 V617F testing: a complete blood count–based framework for improving diagnostic yield
Objectives: We characterized qualitative JAK2 V617F testing performed with and without prespecified hematologic features, compared diagnostic yield between these categories, and evaluated associations between complete blood count (CBC) parameters and qualitative JAK2 V617F positivity. Methods: We retrospectively analyzed 2979 qualitative JAK2 V617F test orders (October 2025 to February 2026) from a large reference laboratory. Orders were categorized by the presence or absence of prespecified hematologic features: erythrocytosis (hemoglobin >16.5 g/dL in men or >16.0 g/dL in women), thrombocytosis (≥450 × 109/L), leukocytosis (>11 × 109/L), and basophilia. Diagnostic yield, odds ratios, and testing efficiency were calculated using same-day CBC specimens; differential counts were exploratory. Financial impact was modeled at the 2026 Medicare Clinical Laboratory Fee Schedule rate ($91.66/test). Results: Overall, 136 of 2979 tests (4.6%) were positive. Testing with at least 1 prespecified feature had higher yield than testing without (6.2% vs 2.1%; odds ratio, 3.07; 95% CI, 1.98-4.77; P < .001). Basophilia (41.1%) and thrombocytosis (24.5%) showed the highest yield. Testing without any prespecified feature required 47.5 tests per positive case. Monocyte and eosinophil counts showed modest associations with positivity. The lower-yield category comprised 39.9% of testing, with a maximum modeled financial impact of $108 900 over 5 months ($261 000 annually). Conclusions: The likelihood of qualitative JAK2 V617F positivity varies markedly with routine CBC parameters, which can identify a higher-yield testing population. Because clinical indications were not available, testing performed without these features cannot be characterized as inappropriate. Criteria based on CBC findings can identify a higher-yield testing population and may serve as a framework for targeted decision support strategies.
- 4 November 2026
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 166 (5)
Laboratory stewardship of qualitative JAK2 V617F testing: a complete blood count–based framework for improving diagnostic yield
Objectives: We characterized qualitative JAK2 V617F testing performed with and without prespecified hematologic features, compared diagnostic yield between these categories, and evaluated associations between complete blood count (CBC) parameters and qualitative JAK2 V617F positivity. Methods: We retrospectively analyzed 2979 qualitative JAK2 V617F test orders (October 2025 to February 2026) from a large reference laboratory. Orders were categorized by the presence or absence of prespecified hematologic features: erythrocytosis (hemoglobin >16.5 g/dL in men or >16.0 g/dL in women), thrombocytosis (≥450 × 109/L), leukocytosis (>11 × 109/L), and basophilia. Diagnostic yield, odds ratios, and testing efficiency were calculated using same-day CBC specimens; differential counts were exploratory. Financial impact was modeled at the 2026 Medicare Clinical Laboratory Fee Schedule rate ($91.66/test). Results: Overall, 136 of 2979 tests (4.6%) were positive. Testing with at least 1 prespecified feature had higher yield than testing without (6.2% vs 2.1%; odds ratio, 3.07; 95% CI, 1.98-4.77; P < .001). Basophilia (41.1%) and thrombocytosis (24.5%) showed the highest yield. Testing without any prespecified feature required 47.5 tests per positive case. Monocyte and eosinophil counts showed modest associations with positivity. The lower-yield category comprised 39.9% of testing, with a maximum modeled financial impact of $108 900 over 5 months ($261 000 annually). Conclusions: The likelihood of qualitative JAK2 V617F positivity varies markedly with routine CBC parameters, which can identify a higher-yield testing population. Because clinical indications were not available, testing performed without these features cannot be characterized as inappropriate. Criteria based on CBC findings can identify a higher-yield testing population and may serve as a framework for targeted decision support strategies.
- Open Access
- 3 November 2026
- Published by BMJ
- p. A1173
1024 AI-based spatial profiling reveals minimal histologic immune differences between homologous recombination–deficient and -proficient ovarian carcinomas
- 3 November 2026
- Published by BMJ
- p. A1173
Open Access1024 AI-based spatial profiling reveals minimal histologic immune differences between homologous recombination–deficient and -proficient ovarian carcinomas
- Open Access
- 19 October 2026
- Published by Wiley in Aging Cell
- Vol. 25 (10) , e70709
SIRT6 Activation Improves Intervertebral Disc Health in the Aging Spine
Aging is a critical risk factor for intervertebral disc degeneration, a major contributor to chronic low back pain. Loss‐of‐function studies showed that SIRT6, a nuclear NAD + ‐dependent deacetylase, maintains disc health. We therefore investigated whether long‐term SIRT6 activation via systemic delivery of the small‐molecular agonist MDL‐800 improves disc health in 24‐month‐old mice. Studies revealed healthy disc morphology, enhanced cell viability, and lower degeneration scores following MDL‐800 treatment. SIRT6 activation decreased H3K9ac levels, improved extracellular matrix quality, and reduced senescence, as evidenced by lower levels of p21, IL‐6, TGF‐β, and CCL2. Tissue RNA‐Seq, measurements of histone 3 modification, and multi‐omics ATAC‐seq/RNA‐seq revealed altered epigenetic (decreased H3K9ac, H3K36me3, and H3K79me2) and transcriptomic landscapes. MDL‐800 increased autophagy without affecting disc cellular bioenergetics. Plasma metabolomics, scRNA‐sequencing of lymphoid tissues (bone marrow and spleen), and cytokine profiling showed good systemic tolerance of the treatment. While we noted a small decrease in vertebral structural parameters and mild hyperalgesia in treated cohorts, there were no vertebral fractures, and the broader motor function and behavior remained unaffected, raising no safety concerns. Our studies underscore the feasibility of SIRT6 activation as a pharmacological strategy to maintain the health of the aging spine.
- 19 October 2026
- Published by Wiley in Aging Cell
- Vol. 25 (10) , e70709
Open AccessSIRT6 Activation Improves Intervertebral Disc Health in the Aging Spine
Aging is a critical risk factor for intervertebral disc degeneration, a major contributor to chronic low back pain. Loss‐of‐function studies showed that SIRT6, a nuclear NAD + ‐dependent deacetylase, maintains disc health. We therefore investigated whether long‐term SIRT6 activation via systemic delivery of the small‐molecular agonist MDL‐800 improves disc health in 24‐month‐old mice. Studies revealed healthy disc morphology, enhanced cell viability, and lower degeneration scores following MDL‐800 treatment. SIRT6 activation decreased H3K9ac levels, improved extracellular matrix quality, and reduced senescence, as evidenced by lower levels of p21, IL‐6, TGF‐β, and CCL2. Tissue RNA‐Seq, measurements of histone 3 modification, and multi‐omics ATAC‐seq/RNA‐seq revealed altered epigenetic (decreased H3K9ac, H3K36me3, and H3K79me2) and transcriptomic landscapes. MDL‐800 increased autophagy without affecting disc cellular bioenergetics. Plasma metabolomics, scRNA‐sequencing of lymphoid tissues (bone marrow and spleen), and cytokine profiling showed good systemic tolerance of the treatment. While we noted a small decrease in vertebral structural parameters and mild hyperalgesia in treated cohorts, there were no vertebral fractures, and the broader motor function and behavior remained unaffected, raising no safety concerns. Our studies underscore the feasibility of SIRT6 activation as a pharmacological strategy to maintain the health of the aging spine.
- 18 October 2026
- Published by American Association for Cancer Research (AACR) in Cancer Epidemiology, Biomarkers & Prevention
- Vol. 35 (10_Supplem) , B095
Abstract B095: Characterizing the composition and diversity of the vaginal microbiome in ovarian cancer
Background: Vaginal dysbiosis, Lactobacillus depletion with anaerobic bacterial enrichment, may be relevant to gynecologic cancer risk and prognosis, yet comprehensive microbiome characterization in ovarian cancer (OC) patients, particularly across racial groups, remains limited. We characterized the prevalence, composition, and demographic predictors of vaginal microbiome dysbiosis among racially diverse OC patients. Methods: We performed 16S rRNA gene sequencing (V1-V3 region) on self-collected vaginal swabs from 132 OC patients enrolled in the population-based ORCHiD study (83.3% non-Hispanic [NH] white, 16.7% NH-Black). Genus- and amplicon sequence variant (ASV)-level composition was characterized, and Latent Dirichlet Allocation topic modeling identified co-occurring microbial community signatures (“topics”). Beta regression assessed associations between topic proportions and race, age, cancer stage, and histologic subtype, with Benjamini-Hochberg false discovery rate (FDR) correction. Targeted species analyses examined four predominant vaginal Lactobacillus species. Results: Lactobacillus was detected in only 47.7% of patients (mean relative abundance 23.5%). Topic modeling identified seven distinct microbial signatures; a Lactobacillus-dominated topic characterized only 26.8% of patients, while dysbiotic, anaerobe-enriched topics dominated 73.2% of the cohort. An anaerobic dysbiosis signature (Peptoniphilus, Anaerococcus) increased significantly with age (35% higher odds per decade of life, FDR q=0.019). NH-Black patients showed a 5-fold higher prevalence of an Actinomycetaceae-classified ASV (ASV54) compared with NH-white patients (40.9% vs 8.2%, FDR q=0.005), the most robust compositional difference observed. L. crispatus was detected only among NH-white patients (6.4% vs 0%), whereas L. iners was more prevalent among NH-Black patients (22.7% vs 10.0%), though species-level differences did not reach statistical significance after correction. Conclusions: OC patients demonstrate a high burden of vaginal microbiome dysbiosis, with distinct age- and race-associated microbial patterns, including a novel Actinomycetaceae ASV enriched among NH-Black patients. These findings establish a foundation for larger, longitudinal studies to determine whether vaginal microbiome profiles could serve as biomarkers for disease monitoring or as therapeutic targets in OC.Generative AI (Claude, Anthropic) was used to assist in drafting this abstract text from the authors' underlying manuscript and data; all content was reviewed and verified for accuracy by the authors prior to submission. Citation Format: April Deveaux, Oyomoare Osazuwa-Peters, Yeon Ji Kim, Pixu Shi, Drew Neish, Ashwini Joshi, Veronica Duck, Ashliegh Williams, Margaret Gates Kuliszewski, Bin Huang, Kevin Ward, Maria Pisu, Thomas Tucker, Rebecca Previs, Andrew Berchuck, Tomi Akinyemiju. Characterizing the composition and diversity of the vaginal microbiome in ovarian cancer [abstract]. In: Proceedings of the 19th AACR Conference on the Science of Cancer Health Disparities; 2026 Oct 18-21; Atlanta, GA. Philadelphia (PA): AACR; Cancer Epidemiol Biomarkers Prev 2026;35(10 Suppl):Abstract nr B095.
- 18 October 2026
- Published by American Association for Cancer Research (AACR) in Cancer Epidemiology, Biomarkers & Prevention
- Vol. 35 (10_Supplem) , B095
Abstract B095: Characterizing the composition and diversity of the vaginal microbiome in ovarian cancer
Background: Vaginal dysbiosis, Lactobacillus depletion with anaerobic bacterial enrichment, may be relevant to gynecologic cancer risk and prognosis, yet comprehensive microbiome characterization in ovarian cancer (OC) patients, particularly across racial groups, remains limited. We characterized the prevalence, composition, and demographic predictors of vaginal microbiome dysbiosis among racially diverse OC patients. Methods: We performed 16S rRNA gene sequencing (V1-V3 region) on self-collected vaginal swabs from 132 OC patients enrolled in the population-based ORCHiD study (83.3% non-Hispanic [NH] white, 16.7% NH-Black). Genus- and amplicon sequence variant (ASV)-level composition was characterized, and Latent Dirichlet Allocation topic modeling identified co-occurring microbial community signatures (“topics”). Beta regression assessed associations between topic proportions and race, age, cancer stage, and histologic subtype, with Benjamini-Hochberg false discovery rate (FDR) correction. Targeted species analyses examined four predominant vaginal Lactobacillus species. Results: Lactobacillus was detected in only 47.7% of patients (mean relative abundance 23.5%). Topic modeling identified seven distinct microbial signatures; a Lactobacillus-dominated topic characterized only 26.8% of patients, while dysbiotic, anaerobe-enriched topics dominated 73.2% of the cohort. An anaerobic dysbiosis signature (Peptoniphilus, Anaerococcus) increased significantly with age (35% higher odds per decade of life, FDR q=0.019). NH-Black patients showed a 5-fold higher prevalence of an Actinomycetaceae-classified ASV (ASV54) compared with NH-white patients (40.9% vs 8.2%, FDR q=0.005), the most robust compositional difference observed. L. crispatus was detected only among NH-white patients (6.4% vs 0%), whereas L. iners was more prevalent among NH-Black patients (22.7% vs 10.0%), though species-level differences did not reach statistical significance after correction. Conclusions: OC patients demonstrate a high burden of vaginal microbiome dysbiosis, with distinct age- and race-associated microbial patterns, including a novel Actinomycetaceae ASV enriched among NH-Black patients. These findings establish a foundation for larger, longitudinal studies to determine whether vaginal microbiome profiles could serve as biomarkers for disease monitoring or as therapeutic targets in OC.Generative AI (Claude, Anthropic) was used to assist in drafting this abstract text from the authors' underlying manuscript and data; all content was reviewed and verified for accuracy by the authors prior to submission. Citation Format: April Deveaux, Oyomoare Osazuwa-Peters, Yeon Ji Kim, Pixu Shi, Drew Neish, Ashwini Joshi, Veronica Duck, Ashliegh Williams, Margaret Gates Kuliszewski, Bin Huang, Kevin Ward, Maria Pisu, Thomas Tucker, Rebecca Previs, Andrew Berchuck, Tomi Akinyemiju. Characterizing the composition and diversity of the vaginal microbiome in ovarian cancer [abstract]. In: Proceedings of the 19th AACR Conference on the Science of Cancer Health Disparities; 2026 Oct 18-21; Atlanta, GA. Philadelphia (PA): AACR; Cancer Epidemiol Biomarkers Prev 2026;35(10 Suppl):Abstract nr B095.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
B-201 Prevalence of Emerging Biomarkers in Seropositive and Seronegative Rheumatoid Arthritis Patients
Background: About 30% of rheumatoid arthritis (RA) patients are seronegative for rheumatoid factor (RF) and cyclic citrullinated peptide (CCP) antibodies, underscoring the need for additional biomarkers to improve diagnostic sensitivity. Emerging biomarkers such as mutated citrullinated vimentin (MCV), citrullinated a-enolase peptide 1 (CEP-1), Sa, and carbamylated protein (CarP) have been proposed to enhance serologic detection. Methods: Biomarker results for RF, CCP, MCV, CEP-1, and CarP were analyzed in 35,678 subjects. Patients were categorized into four groups: RF–CCP– (n=23,439), RF+CCP– (n=2,453), RF–CCP+ (n=1,258), and RF+CCP+ (n=1,749). The prevalence and overlap of emerging biomarker positivity were compared across groups. Results: Overall, 4,295 subjects (23%) had at least one positive biomarker. Among RF–CCP– patients, positivity rates were CarP 31%, MCV 26%, Sa 19.5%, and CEP-1 7.7%, with limited overlap between markers. In RF+CCP– patients, CarP (32%) and MCV (24%) were most frequent. RF–CCP+ patients showed higher reactivity for MCV (19%) and Sa (16%). In contrast, 92% of RF+CCP+ patients demonstrated multiple biomarker positivity, most often combinations involving MCV and Sa. Biomarker distributions differed significantly among RF/CCP-defined groups (p<0.001). Conclusion: Emerging biomarkers are differentially expressed across RA subgroups. Single biomarker positivity predominates in RF–CCP– patients, whereas multiple reactivities are characteristic of RF+CCP+ patients. These findings highlight the limited overlap yet complementary diagnostic value of emerging RA-associated biomarkers, supporting their role in improving the evaluation of seronegative RA.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
B-201 Prevalence of Emerging Biomarkers in Seropositive and Seronegative Rheumatoid Arthritis Patients
Background: About 30% of rheumatoid arthritis (RA) patients are seronegative for rheumatoid factor (RF) and cyclic citrullinated peptide (CCP) antibodies, underscoring the need for additional biomarkers to improve diagnostic sensitivity. Emerging biomarkers such as mutated citrullinated vimentin (MCV), citrullinated a-enolase peptide 1 (CEP-1), Sa, and carbamylated protein (CarP) have been proposed to enhance serologic detection. Methods: Biomarker results for RF, CCP, MCV, CEP-1, and CarP were analyzed in 35,678 subjects. Patients were categorized into four groups: RF–CCP– (n=23,439), RF+CCP– (n=2,453), RF–CCP+ (n=1,258), and RF+CCP+ (n=1,749). The prevalence and overlap of emerging biomarker positivity were compared across groups. Results: Overall, 4,295 subjects (23%) had at least one positive biomarker. Among RF–CCP– patients, positivity rates were CarP 31%, MCV 26%, Sa 19.5%, and CEP-1 7.7%, with limited overlap between markers. In RF+CCP– patients, CarP (32%) and MCV (24%) were most frequent. RF–CCP+ patients showed higher reactivity for MCV (19%) and Sa (16%). In contrast, 92% of RF+CCP+ patients demonstrated multiple biomarker positivity, most often combinations involving MCV and Sa. Biomarker distributions differed significantly among RF/CCP-defined groups (p<0.001). Conclusion: Emerging biomarkers are differentially expressed across RA subgroups. Single biomarker positivity predominates in RF–CCP– patients, whereas multiple reactivities are characteristic of RF+CCP+ patients. These findings highlight the limited overlap yet complementary diagnostic value of emerging RA-associated biomarkers, supporting their role in improving the evaluation of seronegative RA.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
A-315 Monoclonal protein test utilization and guideline adherence in a large national reference laboratory dataset
Background: While clinical and laboratory guidelines recommend combined serum protein electrophoresis (SPE), and serum free light chain (sFLC) testing for the initial evaluation of suspected monoclonal gammopathies for optimal sensitivity, incomplete or non–guideline-adherent testing has been recognized as a concern in real-world practice. Monoclonal protein testing patterns have not been well characterized at a national level, limiting understanding of guideline adherence and opportunities for improvement across ordering specialties. This study uses data from a national reference laboratory to examine overall ordering trends and test utilization within certain specialties. IC10 diagnosis codes were used to gain further insights into ordering practices for clinical indications including screening or monitoring. Methods: Labcorp’s testing database was queried for SPE orders from 2022-2024 (N > 1.8, million samples annually) along with sFLC tests and immunofixation (IFE) ordered a la carte or as part of panel testing. SPE or SPE/IFE ordered with sFLC were considered guideline consistent. If a sFLC was not ordered with SPE or SPE/IFE, the order was considered incomplete. Only SPE testing orders from hematology (HE), oncology(On), neurology(N), nephrology(NEP), primary care(PC), and rheumatology(RHU) provider specialties were included in this study. Using top 20 most frequently appearing ICD10 codes SPE testing orders were parsed by clinical indication for exploratory ICD-10 codes associated with signs and symptoms of multiple myeloma (MM) and for ICD-10 codes associated with monoclonal gammopathy (MG) monitoring. ICD-10 codes for signs and symptoms of MM included codes included anemia (D64.9, D63.1, D69.6), thrombocytopenia (D69.6), renal impairment (N18.30, N18.31, N18.32), hypercalcemia (E83.52), other nonspecific symptoms that raise clinical suspicion for MM (R80.9, R53.83, M25.50, R20.2, R79.89, G62.9). ICD-10 codes for MG monitoring codes included C90.00, C90.01, C90.02 and D47.2 Results: 54.3% of SPE testing orders in the Labcorp testing database from selected specialties did not include sFLC tests, demonstrating a gap in guideline-consistent testing. Panels with all 3 tests were largely underutilized (12.6%), and 33.1% of sFLC orders came in as a la carte orders. In each sub-specialty the following percentage of orders were guideline-consistent: HE:78.3%; ON:76.3%; N:12.3%; NEP:48.1%; PC:25.3%; and RHU:10.5%. In the test group representing incomplete orders, 44.8% had exploratory ICD10 codes compared to 33.9% of guideline-consistent orders; p<0.001). In guideline-consistent orders 47.1% of orders were associated with MG diagnosis codes vs. 8.3% in incomplete orders; p<0.001). Conclusion: Monoclonal protein testing in real-world practice is highly heterogeneous, with substantial underutilization of guideline-consistent sFLC testing, particularly in non-hematology specialties and exploratory diagnostic settings. These findings identify an opportunity for targeted educational and ordering interventions to help improve guideline adherence and potentially support earlier and more complete evaluation of suspected plasma cell disorders.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
A-315 Monoclonal protein test utilization and guideline adherence in a large national reference laboratory dataset
Background: While clinical and laboratory guidelines recommend combined serum protein electrophoresis (SPE), and serum free light chain (sFLC) testing for the initial evaluation of suspected monoclonal gammopathies for optimal sensitivity, incomplete or non–guideline-adherent testing has been recognized as a concern in real-world practice. Monoclonal protein testing patterns have not been well characterized at a national level, limiting understanding of guideline adherence and opportunities for improvement across ordering specialties. This study uses data from a national reference laboratory to examine overall ordering trends and test utilization within certain specialties. IC10 diagnosis codes were used to gain further insights into ordering practices for clinical indications including screening or monitoring. Methods: Labcorp’s testing database was queried for SPE orders from 2022-2024 (N > 1.8, million samples annually) along with sFLC tests and immunofixation (IFE) ordered a la carte or as part of panel testing. SPE or SPE/IFE ordered with sFLC were considered guideline consistent. If a sFLC was not ordered with SPE or SPE/IFE, the order was considered incomplete. Only SPE testing orders from hematology (HE), oncology(On), neurology(N), nephrology(NEP), primary care(PC), and rheumatology(RHU) provider specialties were included in this study. Using top 20 most frequently appearing ICD10 codes SPE testing orders were parsed by clinical indication for exploratory ICD-10 codes associated with signs and symptoms of multiple myeloma (MM) and for ICD-10 codes associated with monoclonal gammopathy (MG) monitoring. ICD-10 codes for signs and symptoms of MM included codes included anemia (D64.9, D63.1, D69.6), thrombocytopenia (D69.6), renal impairment (N18.30, N18.31, N18.32), hypercalcemia (E83.52), other nonspecific symptoms that raise clinical suspicion for MM (R80.9, R53.83, M25.50, R20.2, R79.89, G62.9). ICD-10 codes for MG monitoring codes included C90.00, C90.01, C90.02 and D47.2 Results: 54.3% of SPE testing orders in the Labcorp testing database from selected specialties did not include sFLC tests, demonstrating a gap in guideline-consistent testing. Panels with all 3 tests were largely underutilized (12.6%), and 33.1% of sFLC orders came in as a la carte orders. In each sub-specialty the following percentage of orders were guideline-consistent: HE:78.3%; ON:76.3%; N:12.3%; NEP:48.1%; PC:25.3%; and RHU:10.5%. In the test group representing incomplete orders, 44.8% had exploratory ICD10 codes compared to 33.9% of guideline-consistent orders; p<0.001). In guideline-consistent orders 47.1% of orders were associated with MG diagnosis codes vs. 8.3% in incomplete orders; p<0.001). Conclusion: Monoclonal protein testing in real-world practice is highly heterogeneous, with substantial underutilization of guideline-consistent sFLC testing, particularly in non-hematology specialties and exploratory diagnostic settings. These findings identify an opportunity for targeted educational and ordering interventions to help improve guideline adherence and potentially support earlier and more complete evaluation of suspected plasma cell disorders.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
B-340 Gel You Later: a real-world workflow evaluation of the EXENT® System versus electrophoretic methods
Background: Serum protein electrophoresis (SPE) with reflex immunofixation electrophoresis (IFE) remains an integral component for diagnosis and monitoring of monoclonal gammopathies by detecting and characterizing monoclonal proteins (MPs). However, conventional gel-based SPE/IFE workflows are labor-intensive, highly manual, subject to interpretive variability, resulting in substantial technologist hands-on time. The FDA-cleared EXENT® System, an automated MALDI-ToF mass spectrometry-based platform, was recently developed to streamline MP identification and characterization with reduced operator intervention. This study quantitatively compared workflow demands between conventional gel-based SPE/IFE testing and the EXENT® system using real-world laboratory data. Methods: A time-and-motion workflow study was conducted at Labcorp (Burlington, NC). Hands-on and walk-away times were recorded for operators performing SPE and IFE on traditional electrophoretic systems and on the automated EXENT® system (Thermo Fisher Scientific). One instrument was used for SPE and six for IFE. For the SPE/IFE workflows, observations included one SPE operator, two IFE operators, and one dedicated interpretation operator. For the EXENT® workflow, a single instrument was utilized by two operators who participated in the study; however, the workflow was performed by only one operator at a time. This included a new user who completed the manufacturer’s standard 2.5-day hands-on training. Batch level processing times were evaluated for the analysis (SPE/IFE: n=90 batches; EXENT®: n=50 batches). Recorded time during the study was segregated between hands-on time (sample preparation, interpretation and maintenance) and walk-away time. EXENT® workflow times reflect averages across seven independent runs. Results: EXENT® operators independently completed the full workflow, processing 150 samples (three 50-sample batches) within an eight-hour shift, including six hours of walk-away time. The new operator achieved full proficiency shortly after training and reproduced the manufacturer’s throughput claims. On a per-sample basis, EXENT® demonstrated a 56% reduction in total hands-on time relative to the SPE/IFE workflow, including a 73% reduction in interpretation time, a 67% reduction in maintenance time, and a 125% increase in walk-away time. Additional workflow details are provided in the supporting figure. Conclusion: The EXENT® system was easy to learn, reliable in routine use, and rapidly incorporated into a high-volume clinical workflow. Labcorp operators confirmed that a single operator could process 150 samples in an eight-hour shift, consistent with manufacturer claims. Compared with conventional gel-based SPE/IFE workflows, EXENT® markedly reduced operator hands-on time, particularly for interpretation, and significantly increased walk-away time. These findings indicate that automated mass spectrometry-based workflows may meaningfully reduce labor burden in the clinical laboratory.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
B-340 Gel You Later: a real-world workflow evaluation of the EXENT® System versus electrophoretic methods
Background: Serum protein electrophoresis (SPE) with reflex immunofixation electrophoresis (IFE) remains an integral component for diagnosis and monitoring of monoclonal gammopathies by detecting and characterizing monoclonal proteins (MPs). However, conventional gel-based SPE/IFE workflows are labor-intensive, highly manual, subject to interpretive variability, resulting in substantial technologist hands-on time. The FDA-cleared EXENT® System, an automated MALDI-ToF mass spectrometry-based platform, was recently developed to streamline MP identification and characterization with reduced operator intervention. This study quantitatively compared workflow demands between conventional gel-based SPE/IFE testing and the EXENT® system using real-world laboratory data. Methods: A time-and-motion workflow study was conducted at Labcorp (Burlington, NC). Hands-on and walk-away times were recorded for operators performing SPE and IFE on traditional electrophoretic systems and on the automated EXENT® system (Thermo Fisher Scientific). One instrument was used for SPE and six for IFE. For the SPE/IFE workflows, observations included one SPE operator, two IFE operators, and one dedicated interpretation operator. For the EXENT® workflow, a single instrument was utilized by two operators who participated in the study; however, the workflow was performed by only one operator at a time. This included a new user who completed the manufacturer’s standard 2.5-day hands-on training. Batch level processing times were evaluated for the analysis (SPE/IFE: n=90 batches; EXENT®: n=50 batches). Recorded time during the study was segregated between hands-on time (sample preparation, interpretation and maintenance) and walk-away time. EXENT® workflow times reflect averages across seven independent runs. Results: EXENT® operators independently completed the full workflow, processing 150 samples (three 50-sample batches) within an eight-hour shift, including six hours of walk-away time. The new operator achieved full proficiency shortly after training and reproduced the manufacturer’s throughput claims. On a per-sample basis, EXENT® demonstrated a 56% reduction in total hands-on time relative to the SPE/IFE workflow, including a 73% reduction in interpretation time, a 67% reduction in maintenance time, and a 125% increase in walk-away time. Additional workflow details are provided in the supporting figure. Conclusion: The EXENT® system was easy to learn, reliable in routine use, and rapidly incorporated into a high-volume clinical workflow. Labcorp operators confirmed that a single operator could process 150 samples in an eight-hour shift, consistent with manufacturer claims. Compared with conventional gel-based SPE/IFE workflows, EXENT® markedly reduced operator hands-on time, particularly for interpretation, and significantly increased walk-away time. These findings indicate that automated mass spectrometry-based workflows may meaningfully reduce labor burden in the clinical laboratory.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
A-303 Impact of Tailored Virtual Mentorship on External Quality Assessment (EQA) Performance in Sub-Saharan African Laboratories
Introduction: Access to high-quality laboratory medicine in many low-resource settings (LRS) remains constrained by persistent structural barriers, including workforce shortages, limited funding, inadequate equipment, unreliable supply chains, and restricted access to continuing professional education. Mentorship initiatives to advance laboratory accreditation and quality improvement in these settings have shown mixed results, with sustainability often dependent on long-term partnerships, clear goals, shared commitments, and ongoing evaluation, factors that increase time and cost. However, prior studies have not controlled confounding variables influencing program outcomes, which are best addressed through randomization. We therefore evaluated the impact of a randomized, EQA-focused virtual mentorship program on EQA performance under real-world LRS conditions. Methods: Twenty laboratories enrolled in the Pathologists Overseas EQA program were randomly assigned to a mentorship (11) or control (9) arm using a stratified approach to ensure baseline performance equivalence, with 2024 EQA cycle pass rates, submission rates, and time to enrollment used to establish baseline measures and guide randomization. Both groups submitted bimonthly EQA challenges administered by the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) during the 2025 cycle. Each lab in the control arm met once with the investigators mid-year to address EQA-related questions or program concerns. The mentored laboratories participated in bimonthly one-hour virtual sessions with a board-certified clinical chemist to review EQA reports, receive focused instruction on quality principles, and strengthen corrective action plans. Primary study outcomes included EQA pass rate, submission rate, and analytical performance scores. Multiple linear regression was used to estimate treatment effects while adjusting for baseline performance and time of enrollment. All analyses were conducted in R. Results: At baseline, laboratories were comparable in pass rates, and analytical performance scores. Mean attendance in the mentorship arm was 4.4 of 6 sessions, with 9 of 11 laboratories attending at least four sessions. Control laboratories (8 out of 9) participated in a single mid-year check-in session. When adjusting for baseline performance, there were no statistically significant differences between the mentored and control groups in pass rates (-0.97 percentage points; 95% CI: -10.23 to 8.29; p>.1), submission rates (-9.24 percentage points; 95% CI: -28.89 to 10.40; p>.1), or analytical performance scores (-0.109; 95% CI: -0.485 to 0.267; p>.1). Qualitative findings highlighted persistent systemic barriers to EQA performance that were not mitigated by virtual EQA mentorship, including chronic reagent shortages, onboard reagent degradation due to low testing volumes, inconsistent monitoring of expiration dates, unstable power supply, prolonged instrument downtime, and high staff turnover. Nonetheless, participants described the program as educational and valuable for identifying previously unrecognized recurring gaps and generating data to engage management and drive corrective action. Conclusion: Although limited by its sample size, this study suggests that bimonthly virtual mentorship sessions on EQA alone are insufficient to improve quality without concurrently addressing the broader, interconnected challenges faced by laboratories in LRS. Improving diagnostic quality in these regions requires a multifaceted approach that pairs educational mentorship with robust infrastructure investment and supply chain stabilization.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
A-303 Impact of Tailored Virtual Mentorship on External Quality Assessment (EQA) Performance in Sub-Saharan African Laboratories
Introduction: Access to high-quality laboratory medicine in many low-resource settings (LRS) remains constrained by persistent structural barriers, including workforce shortages, limited funding, inadequate equipment, unreliable supply chains, and restricted access to continuing professional education. Mentorship initiatives to advance laboratory accreditation and quality improvement in these settings have shown mixed results, with sustainability often dependent on long-term partnerships, clear goals, shared commitments, and ongoing evaluation, factors that increase time and cost. However, prior studies have not controlled confounding variables influencing program outcomes, which are best addressed through randomization. We therefore evaluated the impact of a randomized, EQA-focused virtual mentorship program on EQA performance under real-world LRS conditions. Methods: Twenty laboratories enrolled in the Pathologists Overseas EQA program were randomly assigned to a mentorship (11) or control (9) arm using a stratified approach to ensure baseline performance equivalence, with 2024 EQA cycle pass rates, submission rates, and time to enrollment used to establish baseline measures and guide randomization. Both groups submitted bimonthly EQA challenges administered by the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) during the 2025 cycle. Each lab in the control arm met once with the investigators mid-year to address EQA-related questions or program concerns. The mentored laboratories participated in bimonthly one-hour virtual sessions with a board-certified clinical chemist to review EQA reports, receive focused instruction on quality principles, and strengthen corrective action plans. Primary study outcomes included EQA pass rate, submission rate, and analytical performance scores. Multiple linear regression was used to estimate treatment effects while adjusting for baseline performance and time of enrollment. All analyses were conducted in R. Results: At baseline, laboratories were comparable in pass rates, and analytical performance scores. Mean attendance in the mentorship arm was 4.4 of 6 sessions, with 9 of 11 laboratories attending at least four sessions. Control laboratories (8 out of 9) participated in a single mid-year check-in session. When adjusting for baseline performance, there were no statistically significant differences between the mentored and control groups in pass rates (-0.97 percentage points; 95% CI: -10.23 to 8.29; p>.1), submission rates (-9.24 percentage points; 95% CI: -28.89 to 10.40; p>.1), or analytical performance scores (-0.109; 95% CI: -0.485 to 0.267; p>.1). Qualitative findings highlighted persistent systemic barriers to EQA performance that were not mitigated by virtual EQA mentorship, including chronic reagent shortages, onboard reagent degradation due to low testing volumes, inconsistent monitoring of expiration dates, unstable power supply, prolonged instrument downtime, and high staff turnover. Nonetheless, participants described the program as educational and valuable for identifying previously unrecognized recurring gaps and generating data to engage management and drive corrective action. Conclusion: Although limited by its sample size, this study suggests that bimonthly virtual mentorship sessions on EQA alone are insufficient to improve quality without concurrently addressing the broader, interconnected challenges faced by laboratories in LRS. Improving diagnostic quality in these regions requires a multifaceted approach that pairs educational mentorship with robust infrastructure investment and supply chain stabilization.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
A-073 Validation of a Qualitative PCR for Dengue Virus Detection and Serotyping
Background: Dengue is a mosquito-borne viral infection caused by four distinct serotypes: dengue virus 1, 2, 3, and 4 (DENV 1-4). Globally, dengue affects up to 400 million individuals each year and infection can occur multiple times throughout a person’s lifetime. Disease severity varies by the infecting serotype and is often more severe if individuals were previously infected by a different serotype. Methods: Analytical validation was performed using contrived serum samples extracted using the MagNA Pure® 96 (MP96) instrument (Roche Molecular Systems) using the DNA and Viral NA Small Volume kit. Real-time PCR using DiaSorin’s Analyte Specific Reagent (ASR) primer probe pairs for each serotype, Dengue 1-4 (MOL9041, MOL9042, MOL9043, MOL9044), was performed using on the QuantStudio™ 7 (QS7) Flex instrument (Applied Biosystems®). Results: The limit of detection (LoD) in serum was established for each serotype using commercial serum (Golden West). The analytical LoD for each serotype was DENV1: 2,540 copies/ml, DENV2: 2,280 copies/ml, DENV3: 832 copies/ml, and DENV4: 496 copies/ml. The assay demonstrated excellent inter-run precision (%CV) for each serotype at 2x LOD: DENV1 2.37%, DENV2 2.83%, DENV3 2.46%, and DENV4 1.84%. Procedural verification was performed by testing 240 contrived serum samples through the assay, 50 for each serotype at varying concentrations, in addition to 40 serum samples expected to be negative for DENV. Categorical detection was shown to be 100% (240/240). Analytical specificity was assessed by testing pathogens that cause similar symptoms including West Nile Virus, Ehrlichia chaffeensis, Anaplasma phagocytophilum, Borrelia burgdorferi, among others and no cross-reactivity was observed with any pathogen tested. Interference studies using a Sun Diagnostics panel containing elevated triglycerides, hemolysate, total protein, conjugated bilirubin, and unconjugated bilirubin revealed that although some interferents affected assay performance at high concentrations, all serotypes remained detectable. Additional titration to clinically relevant interferent levels demonstrated largely mitigated interference. Stability assessments indicated that dengue viral targets in serum remain stable for 48 hours at room temperature, 7 days refrigerated, 30 days frozen, and through two freeze–thaw cycles. Conclusion: The dengue virus serotyping assay using DiaSorin ASR primer pairs demonstrates high accuracy, sensitivity and specificity enabling rapid and reliable differentiation of dengue serotypes. Moreover, clinical samples are stable, allowing for transport to a laboratory without risk of sample degradation. The use of a high throughput molecular assay for dengue virus serotyping allows laboratories to rapidly respond to the potential emergence of dengue virus in the United States.
- 4 October 2026
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 72 (Supplement)
A-073 Validation of a Qualitative PCR for Dengue Virus Detection and Serotyping
Background: Dengue is a mosquito-borne viral infection caused by four distinct serotypes: dengue virus 1, 2, 3, and 4 (DENV 1-4). Globally, dengue affects up to 400 million individuals each year and infection can occur multiple times throughout a person’s lifetime. Disease severity varies by the infecting serotype and is often more severe if individuals were previously infected by a different serotype. Methods: Analytical validation was performed using contrived serum samples extracted using the MagNA Pure® 96 (MP96) instrument (Roche Molecular Systems) using the DNA and Viral NA Small Volume kit. Real-time PCR using DiaSorin’s Analyte Specific Reagent (ASR) primer probe pairs for each serotype, Dengue 1-4 (MOL9041, MOL9042, MOL9043, MOL9044), was performed using on the QuantStudio™ 7 (QS7) Flex instrument (Applied Biosystems®). Results: The limit of detection (LoD) in serum was established for each serotype using commercial serum (Golden West). The analytical LoD for each serotype was DENV1: 2,540 copies/ml, DENV2: 2,280 copies/ml, DENV3: 832 copies/ml, and DENV4: 496 copies/ml. The assay demonstrated excellent inter-run precision (%CV) for each serotype at 2x LOD: DENV1 2.37%, DENV2 2.83%, DENV3 2.46%, and DENV4 1.84%. Procedural verification was performed by testing 240 contrived serum samples through the assay, 50 for each serotype at varying concentrations, in addition to 40 serum samples expected to be negative for DENV. Categorical detection was shown to be 100% (240/240). Analytical specificity was assessed by testing pathogens that cause similar symptoms including West Nile Virus, Ehrlichia chaffeensis, Anaplasma phagocytophilum, Borrelia burgdorferi, among others and no cross-reactivity was observed with any pathogen tested. Interference studies using a Sun Diagnostics panel containing elevated triglycerides, hemolysate, total protein, conjugated bilirubin, and unconjugated bilirubin revealed that although some interferents affected assay performance at high concentrations, all serotypes remained detectable. Additional titration to clinically relevant interferent levels demonstrated largely mitigated interference. Stability assessments indicated that dengue viral targets in serum remain stable for 48 hours at room temperature, 7 days refrigerated, 30 days frozen, and through two freeze–thaw cycles. Conclusion: The dengue virus serotyping assay using DiaSorin ASR primer pairs demonstrates high accuracy, sensitivity and specificity enabling rapid and reliable differentiation of dengue serotypes. Moreover, clinical samples are stable, allowing for transport to a laboratory without risk of sample degradation. The use of a high throughput molecular assay for dengue virus serotyping allows laboratories to rapidly respond to the potential emergence of dengue virus in the United States.