Coloplast (Denmark)

Types
Company, FunderLocations
Humlebæk, DenmarkRelationships
Latest Publications
- Open Access
- 6 May 2026
- Published by MDPI AG in Journal of Market Access & Health Policy
- Vol. 14 (2) , 29
Impact of a Digital Leakage Notification System on Healthcare Resource Utilisation and Costs for People with Stomas in the United Kingdom: Analysis of Interim Results from a Prospective Longitudinal Study
Background/Objectives: Leakage of stomal effluent adversely affects the quality of life for people living with a stoma and increases healthcare resource utilisation and costs. The Heylo™ digital leakage notification system (DLNS) detects early signs of leakage under the baseplate, enabling proactive stoma management. We evaluated the impact of the DLNS on stoma-related costs in a real-world UK setting. Methods: This costing analysis used data from the first 100 DLNS users with 6 months of follow-up in an ongoing longitudinal observational study (NCT06554015). Costs were calculated as 3-month totals before DLNS (baseline): Month 3, and Month 6 for stoma-related healthcare provider consultations, hospitalisations, and ostomy solution components (pouching systems, supporting products, and DLNS sensor layers). Least squares (LS) means were estimated using a mixed model. Results: Total LS mean costs for stoma-related consultations plus ostomy solution use decreased significantly from baseline by 21.9% at Month 3 (−£304 [95% CI: −£456, −£153]; p = 0.001) and 24.5% at Month 6 (−£340 [95% CI: −£504, −£175]; p < 0.001). Stoma-related consultation costs decreased by 50.7% at Month 3 (−£309 [95% CI: −£447, 171]; p < 0.001) and 57.9% at Month 6 (−£353 [95% CI: −£493, −£213]; p < 0.001), driven by fewer physician and stoma care nurse consultations. Mean ostomy solution costs remained similar from baseline (£784/person) to Month 6 (£782/person; p = 0.955) as DLNS sensor layer costs were offset by less use of other ostomy products. Conclusions: Initiation of the Heylo™ DLNS was associated with significant cost savings from reduced stoma-related consultations, pouching systems, and supporting product use.
- 6 May 2026
- Published by MDPI AG in Journal of Market Access & Health Policy
- Vol. 14 (2) , 29
Open AccessImpact of a Digital Leakage Notification System on Healthcare Resource Utilisation and Costs for People with Stomas in the United Kingdom: Analysis of Interim Results from a Prospective Longitudinal Study
Background/Objectives: Leakage of stomal effluent adversely affects the quality of life for people living with a stoma and increases healthcare resource utilisation and costs. The Heylo™ digital leakage notification system (DLNS) detects early signs of leakage under the baseplate, enabling proactive stoma management. We evaluated the impact of the DLNS on stoma-related costs in a real-world UK setting. Methods: This costing analysis used data from the first 100 DLNS users with 6 months of follow-up in an ongoing longitudinal observational study (NCT06554015). Costs were calculated as 3-month totals before DLNS (baseline): Month 3, and Month 6 for stoma-related healthcare provider consultations, hospitalisations, and ostomy solution components (pouching systems, supporting products, and DLNS sensor layers). Least squares (LS) means were estimated using a mixed model. Results: Total LS mean costs for stoma-related consultations plus ostomy solution use decreased significantly from baseline by 21.9% at Month 3 (−£304 [95% CI: −£456, −£153]; p = 0.001) and 24.5% at Month 6 (−£340 [95% CI: −£504, −£175]; p < 0.001). Stoma-related consultation costs decreased by 50.7% at Month 3 (−£309 [95% CI: −£447, 171]; p < 0.001) and 57.9% at Month 6 (−£353 [95% CI: −£493, −£213]; p < 0.001), driven by fewer physician and stoma care nurse consultations. Mean ostomy solution costs remained similar from baseline (£784/person) to Month 6 (£782/person; p = 0.955) as DLNS sensor layer costs were offset by less use of other ostomy products. Conclusions: Initiation of the Heylo™ DLNS was associated with significant cost savings from reduced stoma-related consultations, pouching systems, and supporting product use.
- 27 April 2026
- Published by Consortium of Multiple Sclerosis Centers in International Journal of MS Care
- Vol. 28 (2) , 131-138
The Impact of Bowel Satisfaction on Mental Health in Multiple Sclerosis: Insights From a Cross-Sectional Study
Background: Bowel dysfunction affects 39% to 72% of people with multiple sclerosis (MS) and is associated with significant mental burden, social stigma, and reduced quality of life. Despite its negative impact, bowel dysfunction is underrecognized, resulting in patient distress and failed self-management. This study aimed to investigate the relationship between bowel function satisfaction and well-being in people with MS. Methods: Of the 1872 people with MS from France, Germany, Italy, and the UK who completed an online survey on bladder- and bowel-related issues of living with MS and on well-being, 1322 identified bowel-related issues and were the focus of this study. Logistic regression models assessed the relationship between bowel problems and well-being, adjusting for demographics and proxies for MS progression. Results: Reduced satisfaction with bowel function and longer duration since MS diagnosis were each linked to approximately twice the odds of lower well-being (OR, 2.17; 95% CI, 1.64-2.87 and OR, 2.16; 95% CI, 1.46-3.20, respectively). Additionally, bowel care self-management was associated with 45% higher odds of lower well-being (OR, 1.45; 95% CI, 1.11-1.89). Other significant risk factors for lower well-being included urinary problems and employment status. Conclusions: People with MS experiencing bowel dysfunction have poorer well-being when managing symptoms independently compared with those receiving help. Early identification and support for managing bowel symptoms are crucial for maintaining well-being.
- 27 April 2026
- Published by Consortium of Multiple Sclerosis Centers in International Journal of MS Care
- Vol. 28 (2) , 131-138
The Impact of Bowel Satisfaction on Mental Health in Multiple Sclerosis: Insights From a Cross-Sectional Study
Background: Bowel dysfunction affects 39% to 72% of people with multiple sclerosis (MS) and is associated with significant mental burden, social stigma, and reduced quality of life. Despite its negative impact, bowel dysfunction is underrecognized, resulting in patient distress and failed self-management. This study aimed to investigate the relationship between bowel function satisfaction and well-being in people with MS. Methods: Of the 1872 people with MS from France, Germany, Italy, and the UK who completed an online survey on bladder- and bowel-related issues of living with MS and on well-being, 1322 identified bowel-related issues and were the focus of this study. Logistic regression models assessed the relationship between bowel problems and well-being, adjusting for demographics and proxies for MS progression. Results: Reduced satisfaction with bowel function and longer duration since MS diagnosis were each linked to approximately twice the odds of lower well-being (OR, 2.17; 95% CI, 1.64-2.87 and OR, 2.16; 95% CI, 1.46-3.20, respectively). Additionally, bowel care self-management was associated with 45% higher odds of lower well-being (OR, 1.45; 95% CI, 1.11-1.89). Other significant risk factors for lower well-being included urinary problems and employment status. Conclusions: People with MS experiencing bowel dysfunction have poorer well-being when managing symptoms independently compared with those receiving help. Early identification and support for managing bowel symptoms are crucial for maintaining well-being.
- Open Access
- 5 February 2026
- Published by Springer Nature in BMC Urology
- Vol. 26 (1)
The Micro-hole Zone Technology as a new era in urinary drainage: a narrative review from bench to bedside
Intermittent catheterization (IC) remains the standard of care for patients who are unable to empty their bladder. However, incomplete bladder emptying and
- 5 February 2026
- Published by Springer Nature in BMC Urology
- Vol. 26 (1)
Open AccessThe Micro-hole Zone Technology as a new era in urinary drainage: a narrative review from bench to bedside
Intermittent catheterization (IC) remains the standard of care for patients who are unable to empty their bladder. However, incomplete bladder emptying and
- 2 February 2026
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 35 (2) , 138-149
Performance of a gelling fibre and silicone foam dressing combination for wound management in the community: a sub-analysis of the VIPES study
Objective: In French community settings, it is common to use a combination of a gelling fibre dressing (Biatain Fiber, Coloplast A/S, Denmark) and a silicone foam dressing (Biatain Silicone, Coloplast A/S, Denmark) for wound management, despite the lack of reimbursement by social security systems. A sub-analysis of the real-world, prospective, observational VIPES (Observatoire en Ville des Plaies ExSudatives) study assessed the use of this dressing combination. Method: In this sub-analysis of the VIPES study, wound healing/wound bed outcomes and nurse/patient satisfaction were assessed. Results: Overall, 76 patients were included. At baseline, mean±standard deviation wound area was 10.1±16.9cm 2 , with low (35.5%), moderate (44.7%) or high (19.7%) exudate levels; 80.3% of patients had exudate pooling. At the final follow-up visit (median (range): 28.5 (2–148) days post-baseline), 27.6% of wounds had healed and 52.7% showed progression towards healing. From baseline to the final follow-up visit, there were significant reductions in wound area (by a mean of 4.7±12.3cm 2 ; p<0.005), exudate level (p<0.0001), and exudate pooling (p<0.0001), and significant improvements in wound edges (p<0.001), and periwound skin (p<0.05). Across 403 gelling fibre dressing removals, most cases showed ‘no/minor’ shrinkage (94.1%) and no adherence to the wound bed (79.8%). At the final follow-up visit, wound improvement was reported by 73.0% of patients and by 77.0% of nurses. For most wounds, nurses agreed that the dressing combination reduced the number of dressing changes, led to greater synergy of action to promote wound healing versus previous dressing(s) used (79.7% and 93.2%, respectively), and achieved optimal healing (94.6% of wounds). Nurses also agreed that the gelling fibre and silicone foam dressing combination was ‘very effective’/‘effective’ for 93.3% of all wounds. Conclusion: In this sub-analysis, combining gelling fibre and silicone foam dressing in community practice supported healing of hard-to-heal exuding wounds.
- 2 February 2026
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 35 (2) , 138-149
Performance of a gelling fibre and silicone foam dressing combination for wound management in the community: a sub-analysis of the VIPES study
Objective: In French community settings, it is common to use a combination of a gelling fibre dressing (Biatain Fiber, Coloplast A/S, Denmark) and a silicone foam dressing (Biatain Silicone, Coloplast A/S, Denmark) for wound management, despite the lack of reimbursement by social security systems. A sub-analysis of the real-world, prospective, observational VIPES (Observatoire en Ville des Plaies ExSudatives) study assessed the use of this dressing combination. Method: In this sub-analysis of the VIPES study, wound healing/wound bed outcomes and nurse/patient satisfaction were assessed. Results: Overall, 76 patients were included. At baseline, mean±standard deviation wound area was 10.1±16.9cm 2 , with low (35.5%), moderate (44.7%) or high (19.7%) exudate levels; 80.3% of patients had exudate pooling. At the final follow-up visit (median (range): 28.5 (2–148) days post-baseline), 27.6% of wounds had healed and 52.7% showed progression towards healing. From baseline to the final follow-up visit, there were significant reductions in wound area (by a mean of 4.7±12.3cm 2 ; p<0.005), exudate level (p<0.0001), and exudate pooling (p<0.0001), and significant improvements in wound edges (p<0.001), and periwound skin (p<0.05). Across 403 gelling fibre dressing removals, most cases showed ‘no/minor’ shrinkage (94.1%) and no adherence to the wound bed (79.8%). At the final follow-up visit, wound improvement was reported by 73.0% of patients and by 77.0% of nurses. For most wounds, nurses agreed that the dressing combination reduced the number of dressing changes, led to greater synergy of action to promote wound healing versus previous dressing(s) used (79.7% and 93.2%, respectively), and achieved optimal healing (94.6% of wounds). Nurses also agreed that the gelling fibre and silicone foam dressing combination was ‘very effective’/‘effective’ for 93.3% of all wounds. Conclusion: In this sub-analysis, combining gelling fibre and silicone foam dressing in community practice supported healing of hard-to-heal exuding wounds.
- Open Access
- 14 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 663
Impact of a Digital Leakage Notification System on Leakage, Quality of Life, Healthcare Resource Utilisation, and Work Productivity: Interim Results from a Longitudinal Real-World Study in the UK
Background: Leakage is a major concern for individuals living with a stoma and may negatively impact quality of life (QoL). A digital leakage notification system (DLNS) recently launched in the UK provides timely notifications to users via their smartphone when faeces is detected underneath the baseplate. This provides predictability and enables users to take proactive measures to help avoid leakages outside the baseplate. Methods: A single-arm, observational, longitudinal study of the DLNS, including its associated support service, has been initiated to follow 300 users for a year in the UK to evaluate long-term health benefits of the DLNS and its implications for healthcare resource utilisation in a real-world setting. The DLNS is prescribed by healthcare professionals (HCPs), and all users were invited to participate in the study. Study participants complete questionnaires capturing data on QoL (using the Ostomy Leak Impact tool), number of leakages outside the baseplate, utilisation of ostomy products, interactions with HCPs, and work productivity (using the Work Productivity and Activity Impairment questionnaire) at baseline and then every third month for one year. Data from the planned interim analysis of the first 100 participants who had been in the study for 6 months is presented. Results: Use of the DLNS for 6 months together with the associated support service was associated with a 51% reduction in leakage episodes outside the baseplate (p < 0.001) and great improvements in QoL (p < 0.001). Use of the DLNS reduced the number of unplanned baseplate changes due to worry about leakage by 47% (p < 0.001) and overall was associated with a reduction in the number of baseplates used by 14% (p = 0.002). Total time spent with HCPs related to stoma care was reduced by 65% after 6 months compared with baseline (p < 0.001). Work absenteeism and presenteeism improved significantly with the use of the DLNS. Conclusions: The interim results of this prospective, longitudinal study provided first insights into the long-term benefits of the DLNS in a real-world setting. ClinicalTrials.gov ID: NCT06554015.
- 14 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 663
Open AccessImpact of a Digital Leakage Notification System on Leakage, Quality of Life, Healthcare Resource Utilisation, and Work Productivity: Interim Results from a Longitudinal Real-World Study in the UK
Background: Leakage is a major concern for individuals living with a stoma and may negatively impact quality of life (QoL). A digital leakage notification system (DLNS) recently launched in the UK provides timely notifications to users via their smartphone when faeces is detected underneath the baseplate. This provides predictability and enables users to take proactive measures to help avoid leakages outside the baseplate. Methods: A single-arm, observational, longitudinal study of the DLNS, including its associated support service, has been initiated to follow 300 users for a year in the UK to evaluate long-term health benefits of the DLNS and its implications for healthcare resource utilisation in a real-world setting. The DLNS is prescribed by healthcare professionals (HCPs), and all users were invited to participate in the study. Study participants complete questionnaires capturing data on QoL (using the Ostomy Leak Impact tool), number of leakages outside the baseplate, utilisation of ostomy products, interactions with HCPs, and work productivity (using the Work Productivity and Activity Impairment questionnaire) at baseline and then every third month for one year. Data from the planned interim analysis of the first 100 participants who had been in the study for 6 months is presented. Results: Use of the DLNS for 6 months together with the associated support service was associated with a 51% reduction in leakage episodes outside the baseplate (p < 0.001) and great improvements in QoL (p < 0.001). Use of the DLNS reduced the number of unplanned baseplate changes due to worry about leakage by 47% (p < 0.001) and overall was associated with a reduction in the number of baseplates used by 14% (p = 0.002). Total time spent with HCPs related to stoma care was reduced by 65% after 6 months compared with baseline (p < 0.001). Work absenteeism and presenteeism improved significantly with the use of the DLNS. Conclusions: The interim results of this prospective, longitudinal study provided first insights into the long-term benefits of the DLNS in a real-world setting. ClinicalTrials.gov ID: NCT06554015.
- 2 January 2026
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 35 (1) , 15-25
In vitro performance of Biatain Superabsorber and use in management of moderately-to-highly exuding wounds
Objective: Superabsorbent wound dressings (SWDs) are often applied for the management of excess exudate in moderately-to-highly exuding wounds; however, in vitro performance characteristics, including absorptive capacity and retention of fluid, can vary significantly between SWD brands. The aims of this study were to: i. assess in vitro absorptive and retention capacities of a new non-adhesive SWD (Biatain Superabsorber, Coloplast A/S, Denmark) and four non-adhesive comparator SWDs (Zetuvit Plus (Hartmann, Germany); ConvaMax Superabsorber (Convatec, UK); Mextra Superabsorbent (Mölnlycke, Sweden); and Vliwasorb (Lohmann & Rauscher, Germany)); ii. assess the ability of the SWDs to reduce matrix metalloproteinase (MMP) activity in vitro; iii. assess bacterial retention within the new SWD; and iv. explore the clinical application of the new SWD in three cases studies. Method: In vitro performance characteristics were assessed for the five SWDs, which included: free swell absorption; absorption under compression (40mmHg); retention of fluid under compression (40mmHg); and sequestration (protease activity reduction) of MMP-2 and MMP-9. Bacterial retention was assessed with the new SWD. Results: Significant variations in in vitro performance characteristics between the SWDs were observed. The new SWD showed higher free swell absorption, retention of fluid under compression and absorption under compression than the comparators. MMP-2 and MMP-9-activity were reduced by 98% and 80%, respectively, after four hours’ incubation with the new SWD, and it effectively absorbed and retained bacteria within the dressing. The three case reports highlighted benefits of using the new SWD in management of moderately-to-highly exuding wounds. Conclusion: The new SWD, Biatain Superabsorber, showed good performance in the different in vitro comparative assessments, and clinical use of the dressing highlighted benefits in the management of wound exudate and in establishing an environment supporting wound healing.
- 2 January 2026
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 35 (1) , 15-25
In vitro performance of Biatain Superabsorber and use in management of moderately-to-highly exuding wounds
Objective: Superabsorbent wound dressings (SWDs) are often applied for the management of excess exudate in moderately-to-highly exuding wounds; however, in vitro performance characteristics, including absorptive capacity and retention of fluid, can vary significantly between SWD brands. The aims of this study were to: i. assess in vitro absorptive and retention capacities of a new non-adhesive SWD (Biatain Superabsorber, Coloplast A/S, Denmark) and four non-adhesive comparator SWDs (Zetuvit Plus (Hartmann, Germany); ConvaMax Superabsorber (Convatec, UK); Mextra Superabsorbent (Mölnlycke, Sweden); and Vliwasorb (Lohmann & Rauscher, Germany)); ii. assess the ability of the SWDs to reduce matrix metalloproteinase (MMP) activity in vitro; iii. assess bacterial retention within the new SWD; and iv. explore the clinical application of the new SWD in three cases studies. Method: In vitro performance characteristics were assessed for the five SWDs, which included: free swell absorption; absorption under compression (40mmHg); retention of fluid under compression (40mmHg); and sequestration (protease activity reduction) of MMP-2 and MMP-9. Bacterial retention was assessed with the new SWD. Results: Significant variations in in vitro performance characteristics between the SWDs were observed. The new SWD showed higher free swell absorption, retention of fluid under compression and absorption under compression than the comparators. MMP-2 and MMP-9-activity were reduced by 98% and 80%, respectively, after four hours’ incubation with the new SWD, and it effectively absorbed and retained bacteria within the dressing. The three case reports highlighted benefits of using the new SWD in management of moderately-to-highly exuding wounds. Conclusion: The new SWD, Biatain Superabsorber, showed good performance in the different in vitro comparative assessments, and clinical use of the dressing highlighted benefits in the management of wound exudate and in establishing an environment supporting wound healing.
- 4 December 2025
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 34 (22) , 1117-1122
Setting a new standard of care: a patient case series to reveal the impact of the new intermittent urinary catheter Luja
This patient case series investigated the impact that the urinary catheter Luja™ with Micro-hole Zone Technology (MHZT) has had on the daily life of patients using intermittent catheters. With intermittent catheterisation (IC) representing the gold standard for daily bladder management for people with urinary tract dysfunctions, the novel urinary catheter Luja is designed to perform differently to conventional eyelet catheters and to address known urinary tract infection risk factors. Using semi-structured patient interviews conducted by health professionals, the real-life experiences of a diverse group of IC patients using the Luja catheter were collected. During the interviews most patients reported positive feedback from using the Luja catheter. Most mentioned perceiving a lower frequency of urinary tract infections, and many mentioned perceiving easier, faster and complete bladder emptying with the Luja catheter compared with their previous conventional eyelet catheter. These findings highlight the advantages that patients using the Luja catheter may experience during daily bladder management.
- 4 December 2025
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 34 (22) , 1117-1122
Setting a new standard of care: a patient case series to reveal the impact of the new intermittent urinary catheter Luja
This patient case series investigated the impact that the urinary catheter Luja™ with Micro-hole Zone Technology (MHZT) has had on the daily life of patients using intermittent catheters. With intermittent catheterisation (IC) representing the gold standard for daily bladder management for people with urinary tract dysfunctions, the novel urinary catheter Luja is designed to perform differently to conventional eyelet catheters and to address known urinary tract infection risk factors. Using semi-structured patient interviews conducted by health professionals, the real-life experiences of a diverse group of IC patients using the Luja catheter were collected. During the interviews most patients reported positive feedback from using the Luja catheter. Most mentioned perceiving a lower frequency of urinary tract infections, and many mentioned perceiving easier, faster and complete bladder emptying with the Luja catheter compared with their previous conventional eyelet catheter. These findings highlight the advantages that patients using the Luja catheter may experience during daily bladder management.
- 4 December 2025
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 34 (22) , 1123-1132
Evaluating the Luja catheter with Micro-hole Zone Technology: insights from patients and health professionals
Background: A new catheter featuring Micro-hole Zone Technology (MHZT) was developed to facilitate a continuous urine flow that ensures complete bladder emptying without the need for repositioning; the aim is to improve clinical outcomes such as bladder trauma and residual volume, ultimately improving patient experiences and reducing urinary tract infection (UTI) risk. Aim: To provide patient-reported and health professional evaluations of experiences with the MHZT catheter (Luja™, Coloplast A/S). Method: Across 14 countries, 564 health professionals and 3103 patients who had used the Luja catheter evaluated the product by completing a questionnaire. Findings: Patients, especially males, and health professionals reported less worry about UTI risks with the Luja catheter, and all patients had a feeling of complete bladder emptying when using this product. Furthermore, most patients found it easy to use. Health professionals also found it easy to train patients to use the Luja catheter, as no repositioning was needed. Patients and health professionals would recommend this catheter product to other intermittent catheter users, and health professionals preferred the MHZT over conventional eyelet catheters. Conclusion: Patients reported improved confidence in bladder emptying and reduced UTI concerns with the Luja catheter, and health professionals, based on their observations, also reported easier training, supporting the benefits of the Luja catheter in intermittent catheterisation routines.
- 4 December 2025
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 34 (22) , 1123-1132
Evaluating the Luja catheter with Micro-hole Zone Technology: insights from patients and health professionals
Background: A new catheter featuring Micro-hole Zone Technology (MHZT) was developed to facilitate a continuous urine flow that ensures complete bladder emptying without the need for repositioning; the aim is to improve clinical outcomes such as bladder trauma and residual volume, ultimately improving patient experiences and reducing urinary tract infection (UTI) risk. Aim: To provide patient-reported and health professional evaluations of experiences with the MHZT catheter (Luja™, Coloplast A/S). Method: Across 14 countries, 564 health professionals and 3103 patients who had used the Luja catheter evaluated the product by completing a questionnaire. Findings: Patients, especially males, and health professionals reported less worry about UTI risks with the Luja catheter, and all patients had a feeling of complete bladder emptying when using this product. Furthermore, most patients found it easy to use. Health professionals also found it easy to train patients to use the Luja catheter, as no repositioning was needed. Patients and health professionals would recommend this catheter product to other intermittent catheter users, and health professionals preferred the MHZT over conventional eyelet catheters. Conclusion: Patients reported improved confidence in bladder emptying and reduced UTI concerns with the Luja catheter, and health professionals, based on their observations, also reported easier training, supporting the benefits of the Luja catheter in intermittent catheterisation routines.
- 2 December 2025
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 34 (12) , 961-969
A clinical investigation of a new gelling fibre dressing containing silver for the management of venous leg ulcers
Objective: To evaluate the performance and safety of Biatain Fiber Ag (Coloplast A/S, Denmark), a new gelling fibre wound dressing containing silver, in venous leg ulcers (VLUs) after four weeks of treatment. Method: This non-comparative, one-armed, open-labelled study included patients from two sites (clinics or community nursing caseloads) in the UK between February and May 2024. The primary endpoint was relative wound area reduction (WAR) after four weeks of treatment. Adverse events (AEs) were also assessed. Results: In total, 50 patients with VLUs either infected or at risk of infection, and with medium-to-high levels of exudate, were included in the intention-to-treat (ITT) population. Of these, 45 patients completed the investigation on treatment and five patients discontinued the treatment. In the primary analysis, the estimated mean relative WAR after four weeks was 46.3% (95% confidence interval (CI): 36.5, 56.2%) in the full analysis set (n=49). In the sensitivity analysis based on the ITT population, it was 43.9% (95% CI: 33.1, 54.7%). In total, three AEs were found to be related to the investigational device; all were non-serious. Conclusion: In this study, treatment of VLUs with the investigational device showed that the mean relative WAR after four weeks of treatment was 46.3%. This reduction in wound area is comparable to the performance of other silver-containing wound dressings. In addition, the results of this clinical investigation revealed no safety concerns. Thus, the study demonstrated that the investigational device is both a safe dressing and one that performs as intended to facilitate VLU healing.
- 2 December 2025
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 34 (12) , 961-969
A clinical investigation of a new gelling fibre dressing containing silver for the management of venous leg ulcers
Objective: To evaluate the performance and safety of Biatain Fiber Ag (Coloplast A/S, Denmark), a new gelling fibre wound dressing containing silver, in venous leg ulcers (VLUs) after four weeks of treatment. Method: This non-comparative, one-armed, open-labelled study included patients from two sites (clinics or community nursing caseloads) in the UK between February and May 2024. The primary endpoint was relative wound area reduction (WAR) after four weeks of treatment. Adverse events (AEs) were also assessed. Results: In total, 50 patients with VLUs either infected or at risk of infection, and with medium-to-high levels of exudate, were included in the intention-to-treat (ITT) population. Of these, 45 patients completed the investigation on treatment and five patients discontinued the treatment. In the primary analysis, the estimated mean relative WAR after four weeks was 46.3% (95% confidence interval (CI): 36.5, 56.2%) in the full analysis set (n=49). In the sensitivity analysis based on the ITT population, it was 43.9% (95% CI: 33.1, 54.7%). In total, three AEs were found to be related to the investigational device; all were non-serious. Conclusion: In this study, treatment of VLUs with the investigational device showed that the mean relative WAR after four weeks of treatment was 46.3%. This reduction in wound area is comparable to the performance of other silver-containing wound dressings. In addition, the results of this clinical investigation revealed no safety concerns. Thus, the study demonstrated that the investigational device is both a safe dressing and one that performs as intended to facilitate VLU healing.
- Open Access
- 29 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8485
Characterizing Urine and Sediment in Individuals with Lower Urinary Tract Dysfunction Utilizing Intermittent Catheters
Background/Objectives: To perform a physicochemical characterization of urine and sediment in intermittent catheterization (IC) users and evaluate the impact of IC with micro-hole zone catheters (MHZC) and conventional two-eyelet catheters (CEC). Methods: Analysis of anonymized urine samples collected from four IC user groups with lower urinary tract dysfunction (LUTD): Newly diagnosed individuals with spinal cord injury (SCI) from an inpatient SCI clinic (A), and community-based IC users with SCI (B), multiple sclerosis (MS) (C), or other conditions than SCI or MS (D). Urine analysis included physicochemical properties, bacterial load, and sediment size, both after collection and following passage through MHZC and CEC. Results: Urine samples from 53 participants were analyzed (groups A: 11, B: 11, C: 9, D: 22). The physicochemical properties of urine were similar to reference values despite the prevalence of bacteriuria ranging from 54.5% to 77.3%. The median [99th percentile] sediment size in the total group was 8.6 µm [50.7 µm] and 8.5 µm [54.1 µm] for group A, 9.2 µm [40.3 µm] for group B, 7.9 µm [48.3 µm] for group C, and 8.9 µm [50.3 µm] for group D. Following catheter passage, the median sediment size for the total group was 8.9 µm with the MHZC and 8.9 µm with the CEC. Conclusions: This two-part study initially presented a novel approach to characterizing urine samples, including sediment from IC users, and, thereafter, an in vitro experiment using the samples to test sediment passage through MHZC and CEC. The results indicated similar urine properties and sediment sizes across groups and did not suggest differences or issues relating to urine and sediment passage through these IC technologies for these groups.
- 29 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8485
Open AccessCharacterizing Urine and Sediment in Individuals with Lower Urinary Tract Dysfunction Utilizing Intermittent Catheters
Background/Objectives: To perform a physicochemical characterization of urine and sediment in intermittent catheterization (IC) users and evaluate the impact of IC with micro-hole zone catheters (MHZC) and conventional two-eyelet catheters (CEC). Methods: Analysis of anonymized urine samples collected from four IC user groups with lower urinary tract dysfunction (LUTD): Newly diagnosed individuals with spinal cord injury (SCI) from an inpatient SCI clinic (A), and community-based IC users with SCI (B), multiple sclerosis (MS) (C), or other conditions than SCI or MS (D). Urine analysis included physicochemical properties, bacterial load, and sediment size, both after collection and following passage through MHZC and CEC. Results: Urine samples from 53 participants were analyzed (groups A: 11, B: 11, C: 9, D: 22). The physicochemical properties of urine were similar to reference values despite the prevalence of bacteriuria ranging from 54.5% to 77.3%. The median [99th percentile] sediment size in the total group was 8.6 µm [50.7 µm] and 8.5 µm [54.1 µm] for group A, 9.2 µm [40.3 µm] for group B, 7.9 µm [48.3 µm] for group C, and 8.9 µm [50.3 µm] for group D. Following catheter passage, the median sediment size for the total group was 8.9 µm with the MHZC and 8.9 µm with the CEC. Conclusions: This two-part study initially presented a novel approach to characterizing urine samples, including sediment from IC users, and, thereafter, an in vitro experiment using the samples to test sediment passage through MHZC and CEC. The results indicated similar urine properties and sediment sizes across groups and did not suggest differences or issues relating to urine and sediment passage through these IC technologies for these groups.