Types
Company, Funder
Locations
Munich, Germany

Latest Publications

  • CTIM-15 Survival outcomes with bizaxofusp (MDNA55) in unresectable IDH-wildtype recurrent glioblastoma (rGBM) using a propensity score-weighted external control arm (ECA) in the intended Phase 3 population

    by Nicholas A Butowski, David A Reardon, Sajeel Chowdhary, Annick Desjardins, Sunit Das, Benjamin M Ellingson, Santosh Kesari, Joanna Phillips, Steven Brem, Andrew Brenner, et al.

    Background: Patients with unresectable IDH-wildtype rGBM have a paucity of available therapeutic options and a median overall survival (OS) of 5-7 months. Bizaxofusp (MDNA55) is an interleukin-4 receptor (IL4R)-targeted fusion protein designed to selectively deliver a cytotoxic payload to GBM cells and the immunosuppressive tumor microenvironment via convection-enhanced delivery (CED). Here we report survival outcomes from MDNA55-05 (NCT02858895) versus an ECA derived from patient-level data in the intended Phase 3 population. Methods: MDNA55-05 was a multicenter Phase 2b study evaluating single-dose intratumoral bizaxofusp administered by MRI-guided CED in adults with unresectable rGBM following first or second relapse. Primary endpoint was OS from eligible relapse date to death or censoring; secondary endpoints included safety and tumor response. OS in the per-protocol (PP) population (N = 43) was compared with a contemporaneous ECA derived from patient registries of standard-of-care patients meeting key eligibility criteria. Additional analysis compared IDH-wildtype patients treated at the recommended Phase 3 dose (RP3D; ≥180 μg) (N = 19), including 12 MGMT-unmethylated tumors, with an IDH-wildtype ECA. Cohorts were balanced using propensity score weighting across 10 baseline prognostic variables, with acceptable balance after weighting. Results: In the PP population (N = 43), bizaxofusp improved mOS versus matched ECA (12.5 vs 7.2 months; HR 0.621, 95% CI 0.413–0.934; p = 0.023). In IDH-wildtype patients at RP3D, mOS substantially improved versus matched ECA (13.7 vs 6.2 months; HR 0.499, 95% CI 0.278–0.895; p = 0.013). Twelve-month OS rates were 52.6% (95% CI 28.7–71.9) for bizaxofusp versus 15.6% (95% CI 6.5–28.4) for matched ECA. Bizaxofusp demonstrated a manageable safety profile; treatment-related adverse events primarily comprised neurological events associated with GBM and the CED procedure. Conclusions: In patients with unresectable IDH-wildtype rGBM treated at RP3D, bizaxofusp markedly improved OS compared with a rigorously matched contemporary ECA. Survival benefit was observed without selection for IL4R expression, supporting registrational development.

  • Open Access

    Geometric and dosimetric effects of an automated clustering and plan optimization pipeline for multiple brain metastasis radiosurgery

    by Adam D. Yock, Guozhen Luo, Sean All, Austin N. Kirschner, Cornelis Kamerling

    Background: Treating multiple brain metastases simultaneously with single‐isocenter multi‐target (SIMT) stereotactic radiosurgery (SRS) can streamline treatment planning and delivery. However, it can also result in targets at large distances from the isocenter, increasing sensitivity to rotational setup errors and requiring wider collimator leaves. Grouping the targets and treating each group with its own plan retains the practical benefits of SIMT SRS while mitigating the concerns of targets at large distances off‐isocenter. Purpose: This work presents a prototype of a newly integrated treatment planning pipeline that automatically clusters targets into groups and subsequently optimizes a plan for each group simultaneously. Treatment scenarios featuring varying numbers of isocenters were compared. Methods: Twenty‐nine treatment courses for patients receiving SRS for 3–15 brain metastases were retrospectively analyzed. Multiple treatment scenarios were prepared for each patient‐course by grouping targets into 1–5 isocenters using k‐means clustering. PTV margins were added using two methods, one with a magnitude that varied with distance to the isocenter, and a second with a constant 1‐mm magnitude. A non‐clinical, command‐line version of the Brainlab Elements Multiple Brain Mets SRS software was used to optimize plans within each scenario simultaneously. Cumulative doses were analyzed in terms of geometric values (target distances to isocenter, total PTV volume), dosimetric values (volume of normal brain (brain‐GTVs) receiving 5, 8, 10, 12, and 18 Gy (V 5Gy , V 8Gy , V 10Gy , V 12Gy , and V 18Gy )), and logistical values (number of Monitor Units (MUs)). A representative sample of 69% of plans with variable margins was reviewed by clinical SRS experts. Results: As the number of isocenters increased, distances from the targets to the isocenters decreased, and the proportion of targets within a given distance increased. For example, 36%, 77%, 94%, 99%, and 100% of targets were within 4 cm of the isocenter for 1–5 isocenters, respectively. For the variable margin method, the total PTV volume relative to the single‐isocenter scenario had a median decrease of 17.5, 24.3, 31.6, and 37.8% for 2–5 isocenters, respectively. Similarly, the relative change in the normal brain dose metrics decreased with increasing number of isocenters (e.g. V 12Gy decreased 20.1, 26.2, 36.2, and 40.9%, respectively). The relative change in dose metrics at each level was found to have a linear relationship with that of the total PTV volume (e.g. V 12Gy , R 2 = 0.81). For the constant margin method, total PTV volume remained constant, but normal brain dose metrics still decreased due to the grouping and simultaneous plan optimization alone (e.g. V 12Gy decreased 6.4, 10.5, 15.1, and 17.1%). Regarding logistical values, the number of MUs increased with each additional isocenter for both margin methods, but at a rate slower than proportional to the number of isocenters. Of the evaluated plans, nearly all (97.7%) were clinically acceptable without modification. Conclusion: The SIMT SRS treatment planning pipeline presented here features automatic grouping of targets followed by automatic dose optimization of up to five isocenters. By quantifying the geometric, dosimetric, and logistical effects of adding isocenters, this pipeline can empower clinicians to make resource‐conscious treatment decisions optimal for each patient.

  • Open Access

    Engagement is not encoding: Outcome alignment determines the effectiveness of mixed reality in medical education

    by Nadia Karnatz, David Kaffka, Angela Rosa Caso, Michael Schwerter, Shufang Liu, Raymond Wong, Aida Parviz, Majeed Rana

  • Open Access

    Template guided versus freehand rod bending in spinal deformity surgery: a feasibility study

    by L. Bättig, A. R. Dixon, E. Molero Hidalgo, N. Hejrati, F. C. Stengel, F. Corr, T. Schöfl, L. Feuerstein, N. A. Pogonitz, S. Singh, et al.

    Spinal deformity correction relies on osteotomies and precisely contoured rods, which are critical for restoring sagittal alignment. Inaccurate rod bending may compromise alignment and increase the risk of junctional failure. This feasibility study compares the accuracy of template-guided versus freehand rod contouring in a simulated environment. Using SurgiMap® software, 12 double-curved rods were designed from full-spine radiographs. Six surgeons from a tertiary spine centre bent rods freehand or using 2D paper templates. Two rod specifications were tested: ⌀4.0 mm stainless steel rods for cervicothoracic and ⌀6.0 mm cobalt-chromium rods for thoracolumbar models, representing the mechanical extremes of commonly used spinal implant configurations. Digitized rod contour angles (RCAs) were compared with planned contours using tangent-vector analysis. Template-guided bending significantly improved accuracy (mean RCA difference: 2.6° ± 1.3°, p < 0.01) and required fewer bends (4.1 ± 1.3, p < 0.01), without a significant time increase (p = 0.11). Subgroup analysis showed significant improvement only in less experienced surgeons. In conclusion, template-based rod bending improved sagittal contouring accuracy and efficiency in a simulated environment, with the greatest benefit for less experienced surgeons. Further clinical studies are necessary to confirm these results.

  • Open Access

    Mixed-Reality-Assisted Physician-Modified Stent Grafts: An Experimental Pre-Clinical Feasibility Study Using the Valiant Captivia and Endurant II Stent Graft Systems

    by Johannes Hatzl, Jana Ebner, Christian Uhl, Andreas Sebastian Peters, Alexandru Barb, Jonathan Fiering, Alexandra Marquardt, Dittmar Böckler

    Objectives: Physician-modified endografts (PMEGs) expand endovascular treatment options in urgent or cost-sensitive settings where industry-provided custom-made devices (CMDs) are not available. Current PMEG manufacturing techniques are time-consuming, lack standardization, and often require repeated adjustments to achieve strut-free fenestration positioning. Mixed reality (MxR) may streamline this process by overlaying virtual templates directly onto the physical stent graft guiding fenestration positioning. Methods: We developed a standardized MxR-assisted workflow for four-fenestrated PMEG preparations and compared it to a conventional marking technique. In this experimental set-up, between May 2025 and July 2025, three stent grafts were evaluated (Endurant II® 28 mm, Valiant Captivia® 30 mm, and Valiant Captivia® 32 mm). Five observers performed fenestration marking on 20 grafts per device type (10 per method), resulting in 60 PMEGs and 240 fenestrations. Outcomes included absolute positional error, relative positional error, number of strut-free fenestrations, number of re-attempts to achieve strut-free configuration, time required, and usability assessed via the System Usability Scale (SUS). Results: Across 240 fenestrations, both methods achieved high accuracy. Median absolute errors ranged from 0 to 1.25 mm for the conventional method and 0 to 1.75 mm for MxR. Relative positional errors were similarly small, with no significant differences between methods. MxR achieved higher rates of strut-free fenestration in the 28 mm Endurant II® device. Re-attempts were fewer with MxR. Median procedure time was significantly reduced for the MxR-assisted workflow in Valiant Captivia 30 mm (5.0 vs. 9.8 min, p = 0.049) and 32 mm (5.6 vs. 8.2 min, p = 0.049) while a trend was observed for Endurant II (7.5 vs. 15.6 min, p = 0.066). SUS scores favored MxR (76.2 vs. 62.6), though not significantly. Conclusions: The MxR-assisted PMEG production workflow seems promising in this pre-clinical, experimental study and warrants continued development and investigation.


  • Open Access

    Initial Experience with Correlation Object–Based DRR Targeting Using Stereoscopic X-Ray Imaging in Lung SBRT

    by Marlies Boussaer, Cristina Teixeira, Kajetan Berlinger, Selma Ben Mustapha, Anne-Sophie Bom, Sven Van Laere, Mark De Ridder, Thierry Gevaert

    Background/Objectives: Despite significant advances in imaging technology, real-time intra-fraction monitoring of moving targets remains a challenge in markerless radiotherapy. This retrospective study investigates the use of ExacTrac Dynamic by Brainlab as an intra-fraction monitoring tool for stereotactic body radiotherapy (SBRT) in both early-stage NSCLC and oligometastatic disease. Methods: A total of 63 X-ray pairs from 21 patients were analyzed to evaluate tumor visualization with and without a surrogate approach. Statistical analysis was conducted to determine whether failures could be attributed to tumor size or localization using the Mann–Whitney U-test and Fisher’s exact test. The accuracy of the X-ray/digitally reconstructed radiograph (DRR) surrogate-based fusion was assessed by calculating and comparing the corresponding 3D vectors according to the linear mixed effects model, with a random slope effect for size of surrogate and a random intercept per patient. Results: Surrogates enhanced tumor visualization on X-ray/DRR fusions from 14.3% to 75.5%. Tumor size and lung affected (left or right) did not predict visualization success. Tumor location, however, tended to influence visibility, with lesions in the upper lobes being more readily visualized (88%) than those in the lower lobes (48.1%), although no statistical significance was reported (p > 0.05). Regarding geometric accuracy, 76% of the analyzed data points deviated less than 5 mm in the 3D vector measurements, the mean values were around 4 mm (±3 mm), and the medians were within 3 mm across all conditions. No statistically significant differences (p > 0.05) were found based on the surrogate size or the triggering time of the X-ray during the breathing cycle. Conclusions: Surrogate-based DRRs, referred to as Correlation Objects, demonstrate consistent geometric accuracy across multiple surrogate sizes and X-ray acquisitions, supporting the clinical translation of markerless lung targeting workflows for lung SBRT.

  • Open Access

    The development status of entrustable professional activities-based curricula in orthopedic and neurosurgical spinal surgery: a systematic review

    by Maximilian Domann, Fabiana Phillips, Martin R. Fischer, Matthias Stadler

    Background: Postgraduate medical training often lacks clearly defined, assessable outcomes. Entrustable professional activities (EPAs) have emerged as a promising framework for competency-based training, aiming to improve transparency, accountability, and efficiency in specialist education. This systematic review investigates the current development status of EPA-based curricula in orthopedic and neurosurgical spinal surgery and highlights their potential to address educational challenges in this high-stakes field. Methods: A systematic review was conducted combining database studies (PubMed and Embase) and gray literature screening through professional societies’ websites and direct inquiries. Two reviewers independently screened, extracted, and synthesized the data. Given the anticipated heterogeneity among the included studies, a narrative synthesis was performed, while a quantitative synthesis was not feasible. No formal risk-of-bias assessment was conducted; however, potential sources of bias related to language, scope, and publication period were acknowledged and discussed. Results: Out of 15,768 initial records, only 4 relevant papers were identified. The EPAs in these studies were developed primarily through expert consensus methods such as modified Delphi or nominal group techniques. Additionally, among the 10 professional societies analyzed, only the AO Foundation (AO Spine) and the Royal College of Physicians and Surgeons of Canada provided explicit EPA frameworks for spinal surgery, contributing together to 26 EPAs. The limited number and heterogeneity of sources underscore the exploratory nature of this review and the current lack of standardized, spine-specific EPA curricula. Conclusion: EPA-based curricula in spinal surgery remain largely undeveloped. While conceptual frameworks exist, their implementation into structured residency programs is still in its infancy. This review provides a foundational overview of the existing EPAs and methodological approaches, offering a reference point for future curriculum development. Collaborative initiatives among professional societies are strongly encouraged to define, validate, and implement specialty-specific EPAs for spinal surgery, fostering competency-based education and improving training outcomes.


  • Open Access

    Application of a human stereotactic system for image-guided deep brain stimulation neurosurgery in a swine model

    by Kristen M. Scheitler, Juan M. Rojas-Cabrera, Sara A. Vettleson-Trutza, Sheng-Ta Tsai, Guillermo K. Pons-Monnier, Mohamed M. El-Gohary, Ron Scheer, Youngjong Kwak, Damiano G. Barone, Charles D. Blaha, et al.


  • Open Access

    Feasibility of Mixed Reality-assisted physician-modified endografts

    by Johannes Hatzl, Christian Uhl, Jana Ebner, Alexandra Marquardt, Dimitrios David Papazoglou, Nina Bauer, Katrin Meisenbacher, Daniel Henning, Andreas Sebastian Peters, Dittmar Böckler


  • Software Support Tools for Reirradiation: A Report From Reirradiation Collaborative Group (ReCOG) 2024

    by Charles K. Matrosic, Piotr Andrzejewski, Alanah Bergman, Nick Chng, Issam El Naqa, Philipp Freislederer, Lone Hoffmann, Andrew Hope, Dustin Jacqmin, Colin Kelly, et al.