SUNY Polytechnic Institute

Types
Education, FunderLocations
Utica, United StatesRelationships
Latest Publications
- 23 November 2026
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 37 (11)
Comparative Study on the Effect of Mono‐ and Bis‐Furan Crosslinkers on PMMA Polymers Modified Glassy Carbon Electrode for Unsafe Mercury Ion Detection
In this paper, a comparative study has been done between two novel highly cross‐linked polymers based on poly(methyl methacrylate) (PMMA) using two furan‐based cross‐linking agents, 2,5‐bis(aminomethyl)furan (BAF) and difurfurylamine (DFA), to investigate how the type and loading of crosslinker influence the properties and the sensing applications of the resulting polymers. The structural, morphological, and thermal properties of the synthesized cross‐linked polymers (BAF–PMMA and DFA–PMMA) were investigated using Fourier transform infrared spectroscopy (FT‐IR), scanning electron microscopy (SEM), X‐ray diffraction (XRD), and thermogravimetric analysis (TGA). The results revealed significant improvements in the amorphous nature, surface porosity, and thermal stability of PMMA upon cross‐linking, emphasizing the critical role of the crosslinker's aromatic content and loading. In addition, the electrochemical sensing performance of DFA–PMMA was investigated for Hg 2+ detection. The fabricated sensor (DFA–PMMA 5 /GCE) exhibits an impressive linear dynamic range (LDR) from 0.1 mM to 0.1 nM, with a detection limit (DL) as low as 93.75 pM toward Hg 2+ ions. Moreover, it demonstrates a high sensitivity of 94.9367 μAμM −1 cm −2 , enabling precise detection of trace concentrations of Hg 2+ . The sensor's reproducibility and stability are found to be highly appreciable, ensuring reliable performance over extended use. This sensor shows considerable potential for environmental and analytical applications where low‐level mercury detection is crucial.
- 23 November 2026
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 37 (11)
Comparative Study on the Effect of Mono‐ and Bis‐Furan Crosslinkers on PMMA Polymers Modified Glassy Carbon Electrode for Unsafe Mercury Ion Detection
In this paper, a comparative study has been done between two novel highly cross‐linked polymers based on poly(methyl methacrylate) (PMMA) using two furan‐based cross‐linking agents, 2,5‐bis(aminomethyl)furan (BAF) and difurfurylamine (DFA), to investigate how the type and loading of crosslinker influence the properties and the sensing applications of the resulting polymers. The structural, morphological, and thermal properties of the synthesized cross‐linked polymers (BAF–PMMA and DFA–PMMA) were investigated using Fourier transform infrared spectroscopy (FT‐IR), scanning electron microscopy (SEM), X‐ray diffraction (XRD), and thermogravimetric analysis (TGA). The results revealed significant improvements in the amorphous nature, surface porosity, and thermal stability of PMMA upon cross‐linking, emphasizing the critical role of the crosslinker's aromatic content and loading. In addition, the electrochemical sensing performance of DFA–PMMA was investigated for Hg 2+ detection. The fabricated sensor (DFA–PMMA 5 /GCE) exhibits an impressive linear dynamic range (LDR) from 0.1 mM to 0.1 nM, with a detection limit (DL) as low as 93.75 pM toward Hg 2+ ions. Moreover, it demonstrates a high sensitivity of 94.9367 μAμM −1 cm −2 , enabling precise detection of trace concentrations of Hg 2+ . The sensor's reproducibility and stability are found to be highly appreciable, ensuring reliable performance over extended use. This sensor shows considerable potential for environmental and analytical applications where low‐level mercury detection is crucial.
- Open Access
- 23 November 2026
- Published by IOP Publishing in Journal of Physics: Materials
- Vol. 9 (4) , 045017
Ultrathin BN layers grown on sapphire by molecular beam epitaxy at low and high temperature
Ultrathin boron nitride (BN) layers have been synthesized by nitrogen plasma-assisted molecular beam epitaxy on c-plane sapphire substrate at two low (50 °C) and high temperature (1000 °C), respectively. Sharp and clear light absorption peaks very close to 200 nm with nearly zero absorbance in the range of 225−700 nm have been measured, irrespective of the growth temperature. The present study demonstrates the formation of sp 2 -hybridized BN material at both temperatures, albeit with different polytypes. The hexagonal BN polytype was mostly developed when the layers are grown at the higher temperature, whereas the less ordered turbostratic BN polytype formed primarily when the layers are grown near room temperature (RT). We observe a noticeable enhancement in Young modulus and hardness for the sample grown near RT, suggesting that the deposition of ultrathin BN material at low temperature is a meaningful strategy to further increase the sapphire surface resistance against mechanical damage yet preserving its transparency.
- 23 November 2026
- Published by IOP Publishing in Journal of Physics: Materials
- Vol. 9 (4) , 045017
Open AccessUltrathin BN layers grown on sapphire by molecular beam epitaxy at low and high temperature
Ultrathin boron nitride (BN) layers have been synthesized by nitrogen plasma-assisted molecular beam epitaxy on c-plane sapphire substrate at two low (50 °C) and high temperature (1000 °C), respectively. Sharp and clear light absorption peaks very close to 200 nm with nearly zero absorbance in the range of 225−700 nm have been measured, irrespective of the growth temperature. The present study demonstrates the formation of sp 2 -hybridized BN material at both temperatures, albeit with different polytypes. The hexagonal BN polytype was mostly developed when the layers are grown at the higher temperature, whereas the less ordered turbostratic BN polytype formed primarily when the layers are grown near room temperature (RT). We observe a noticeable enhancement in Young modulus and hardness for the sample grown near RT, suggesting that the deposition of ultrathin BN material at low temperature is a meaningful strategy to further increase the sapphire surface resistance against mechanical damage yet preserving its transparency.
- 22 November 2026
- Published by Springer Nature in MRS Advances
- p. 1-9
Conductive polymer and delafossite oxide coupled CNT electrodes for fiber-shaped DSSCs
- 22 November 2026
- Published by Springer Nature in MRS Advances
- p. 1-9
Conductive polymer and delafossite oxide coupled CNT electrodes for fiber-shaped DSSCs
- Open Access
- 10 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (22) , 8767
The Missing Dimension in Lung-Protective Ventilation: Physiologically Directed Inspiratory and Expiratory Time
Acute respiratory distress syndrome (ARDS) remains a major clinical problem, and treatment is largely supportive with mechanical ventilation. When ventilator settings are poorly matched to lung physiology, ventilator-induced lung injury can occur and worsen outcomes. Two key features of ARDS limit the effectiveness of conventional ventilation strategies: (1) elevated pleural pressure (Ppl), particularly in dependent lung regions, and (2) time- and pressure-dependent (T-PD) mechanics, in which injured lung units open slowly but collapse quickly at any given airway pressure. These features may limit the effectiveness of standardized approaches such as ARDS Network low tidal volume ventilation, which was not designed to adapt to high Ppl or T-PD dynamics. Airway pressure release ventilation (APRV) has shown promising results in animal studies, meta-analyses, computational models, and small clinical trials, although no large multicenter randomized controlled trial has yet to demonstrate a mortality benefit. APRV can be individualized to evolving lung pathology using the time-controlled adaptive ventilation (TCAV) method. TCAV is designed to address elevated Ppl through a prolonged inspiratory phase (THigh) that enables viscoelastic recruitment by creep, and a brief expiratory release (TLow) that prevents the newly opened alveoli from re-collapsing. Recruitment may be further facilitated by transient airway pressure perturbations generated at the collision of inspiratory and expiratory gas flow (the “gas hammer” hypothesis). Recruitment first occurs in areas with low Ppl, such that transpulmonary pressure (PTP) is positive. Lung tissue recruitment reduces the mass load from edema and atelectasis, progressively lowering Ppl and resulting in a positive PTP. Gradually decreasing Ppl from nondependent to dependent regions as the lung recruits modifies the airway pressure gradient, allowing the entire lung to be gradually reopened. The TLow is personalized using the slope of the expiratory flow curve, providing a real-time indicator of respiratory system compliance and mechanical behavior analogous to passive spirometry. The TCAV method supports progressive recruitment within T-PD lung regions, gradually reducing Ppl, increasing PTP, and promoting more homogeneous ventilation distribution across the injured lung.
- 10 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (22) , 8767
Open AccessThe Missing Dimension in Lung-Protective Ventilation: Physiologically Directed Inspiratory and Expiratory Time
Acute respiratory distress syndrome (ARDS) remains a major clinical problem, and treatment is largely supportive with mechanical ventilation. When ventilator settings are poorly matched to lung physiology, ventilator-induced lung injury can occur and worsen outcomes. Two key features of ARDS limit the effectiveness of conventional ventilation strategies: (1) elevated pleural pressure (Ppl), particularly in dependent lung regions, and (2) time- and pressure-dependent (T-PD) mechanics, in which injured lung units open slowly but collapse quickly at any given airway pressure. These features may limit the effectiveness of standardized approaches such as ARDS Network low tidal volume ventilation, which was not designed to adapt to high Ppl or T-PD dynamics. Airway pressure release ventilation (APRV) has shown promising results in animal studies, meta-analyses, computational models, and small clinical trials, although no large multicenter randomized controlled trial has yet to demonstrate a mortality benefit. APRV can be individualized to evolving lung pathology using the time-controlled adaptive ventilation (TCAV) method. TCAV is designed to address elevated Ppl through a prolonged inspiratory phase (THigh) that enables viscoelastic recruitment by creep, and a brief expiratory release (TLow) that prevents the newly opened alveoli from re-collapsing. Recruitment may be further facilitated by transient airway pressure perturbations generated at the collision of inspiratory and expiratory gas flow (the “gas hammer” hypothesis). Recruitment first occurs in areas with low Ppl, such that transpulmonary pressure (PTP) is positive. Lung tissue recruitment reduces the mass load from edema and atelectasis, progressively lowering Ppl and resulting in a positive PTP. Gradually decreasing Ppl from nondependent to dependent regions as the lung recruits modifies the airway pressure gradient, allowing the entire lung to be gradually reopened. The TLow is personalized using the slope of the expiratory flow curve, providing a real-time indicator of respiratory system compliance and mechanical behavior analogous to passive spirometry. The TCAV method supports progressive recruitment within T-PD lung regions, gradually reducing Ppl, increasing PTP, and promoting more homogeneous ventilation distribution across the injured lung.
- Open Access
- 9 November 2026
- Published by MDPI AG in Preprints.org
Relativistic Generalized Uncertainty Principle and Maximum Acceleration near a Black Hole Horizon
We investigate the maximum acceleration allowed by the Relativistic Generalized Uncertainty Principle (RGUP) and its implications for black hole (BH) physics. Previous analyses based on the nonrelativistic Generalized Uncertainty Principle (GUP) yield the universal scale \( a_{max}\approx c{{}^2}/l_{P} \), where c is the speed of light and lP is the Planck length. We extend this analysis to relativistic quantum mechanics and Schwarzschild spacetime. For an observer in flat spacetime or in free fall in a gravitational field, the RGUP reduces to the GUP and the same finite maximum acceleration is recovered. In contrast, for a fiducial observer held at fixed Schwarzschild radius rg, the metric dependence of the RGUP qualitatively changes the result: the quantum-corrected maximum proper acceleration remains finite away from the horizon but diverges as the Schwarzschild radial coordinate approaches the gravitational radius. Thus, the RGUP does not remove the classical divergence for a static observer at the horizon. This difference between freely falling and fiducial observers provides a quantum-mechanical manifestation of the observer dependence associated with the BH horizon and suggests a form of BH complementarity at the level of maximum acceleration.- 9 November 2026
- Published by MDPI AG in Preprints.org
Open AccessRelativistic Generalized Uncertainty Principle and Maximum Acceleration near a Black Hole Horizon
We investigate the maximum acceleration allowed by the Relativistic Generalized Uncertainty Principle (RGUP) and its implications for black hole (BH) physics. Previous analyses based on the nonrelativistic Generalized Uncertainty Principle (GUP) yield the universal scale \( a_{max}\approx c{{}^2}/l_{P} \), where c is the speed of light and lP is the Planck length. We extend this analysis to relativistic quantum mechanics and Schwarzschild spacetime. For an observer in flat spacetime or in free fall in a gravitational field, the RGUP reduces to the GUP and the same finite maximum acceleration is recovered. In contrast, for a fiducial observer held at fixed Schwarzschild radius rg, the metric dependence of the RGUP qualitatively changes the result: the quantum-corrected maximum proper acceleration remains finite away from the horizon but diverges as the Schwarzschild radial coordinate approaches the gravitational radius. Thus, the RGUP does not remove the classical divergence for a static observer at the horizon. This difference between freely falling and fiducial observers provides a quantum-mechanical manifestation of the observer dependence associated with the BH horizon and suggests a form of BH complementarity at the level of maximum acceleration. - Open Access
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 8162-8171
HexMIL: Hierarchical Attention MIL for Ante-Hoc Explainable Detection of AI-Manipulated CT Volumes
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 8162-8171
Open AccessHexMIL: Hierarchical Attention MIL for Ante-Hoc Explainable Detection of AI-Manipulated CT Volumes
- Open Access
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 18018-18022
Deepfake Forensics Workshop (DFF-2026): Detection, Attribution, Recognition, and Adversarial Challenges in the Era of AI-Generated Media
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 18018-18022
Open AccessDeepfake Forensics Workshop (DFF-2026): Detection, Attribution, Recognition, and Adversarial Challenges in the Era of AI-Generated Media
- Open Access
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 17478-17482
Adversarial Attacks on Deepfake Detectors: A Challenge in the Era of AI-Generated Media
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 17478-17482
Open AccessAdversarial Attacks on Deepfake Detectors: A Challenge in the Era of AI-Generated Media
- Open Access
- 8 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8714
Adaptive Dynamic Subtidal Volume Ventilation (ADSV) Technology: Fluid Dynamic Principles and Physiologic Rationale for Personalized Treatment of Acute Respiratory Distress Syndrome
Acute respiratory distress syndrome (ARDS) imposes regionally heterogeneous, time-dependent alterations in pulmonary mechanics that fundamentally limit conventional ventilation strategies. Fixed-parameter approaches targeting global pressure, volume, or timing thresholds cannot simultaneously address the competing demands of alveolar recruitment and volutrauma prevention, nor can they adapt dynamically to the wide regional variation in compliance, resistance, and expiratory time constants that characterizes the injured lung. These limitations persist across volume-controlled, pressure-controlled, high-frequency oscillatory, and time-controlled ventilation strategies. This article provides a clinically oriented narrative review of the physiologic and fluid-dynamic principles underlying Adaptive Dynamic Subtidal Ventilation (ADSV), an emerging ventilation technology that incorporates a proximal airway device—the Sliding Venturi—that passively modulates subtidal gas delivery in response to evolving respiratory system mechanics. The device utilizes the Bernoulli and Venturi effects to establish a passive pressure–flow feedback mechanism in which downstream respiratory system mechanics influence gas entrainment, delivered subtidal volume, and airway pressure. In the low-compliance (high-elastance) ARDS lung, this may limit gas entrainment and subtidal volume delivery while maintaining distending pressure. As compliance improves, entrainment may increase, permitting larger subtidal volumes at lower pressures. This self-regulating behavior operates on millisecond timescales and adapts to changes in overall respiratory system mechanics. Patient-proximal placement facilitates rapid expiratory venting, potentially reducing circuit-related expiratory resistance and dynamic hyperinflation, although these effects require experimental validation. ADSV therefore provides a fluid-dynamic framework for mechanically responsive subtidal ventilation that may help manage the changing respiratory mechanics associated with ARDS. Bench and computational studies, followed by preclinical and clinical investigations, are needed to characterize device performance, evaluate regional physiological effects, and establish safety and efficacy in ARDS.
- 8 November 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8714
Open AccessAdaptive Dynamic Subtidal Volume Ventilation (ADSV) Technology: Fluid Dynamic Principles and Physiologic Rationale for Personalized Treatment of Acute Respiratory Distress Syndrome
Acute respiratory distress syndrome (ARDS) imposes regionally heterogeneous, time-dependent alterations in pulmonary mechanics that fundamentally limit conventional ventilation strategies. Fixed-parameter approaches targeting global pressure, volume, or timing thresholds cannot simultaneously address the competing demands of alveolar recruitment and volutrauma prevention, nor can they adapt dynamically to the wide regional variation in compliance, resistance, and expiratory time constants that characterizes the injured lung. These limitations persist across volume-controlled, pressure-controlled, high-frequency oscillatory, and time-controlled ventilation strategies. This article provides a clinically oriented narrative review of the physiologic and fluid-dynamic principles underlying Adaptive Dynamic Subtidal Ventilation (ADSV), an emerging ventilation technology that incorporates a proximal airway device—the Sliding Venturi—that passively modulates subtidal gas delivery in response to evolving respiratory system mechanics. The device utilizes the Bernoulli and Venturi effects to establish a passive pressure–flow feedback mechanism in which downstream respiratory system mechanics influence gas entrainment, delivered subtidal volume, and airway pressure. In the low-compliance (high-elastance) ARDS lung, this may limit gas entrainment and subtidal volume delivery while maintaining distending pressure. As compliance improves, entrainment may increase, permitting larger subtidal volumes at lower pressures. This self-regulating behavior operates on millisecond timescales and adapts to changes in overall respiratory system mechanics. Patient-proximal placement facilitates rapid expiratory venting, potentially reducing circuit-related expiratory resistance and dynamic hyperinflation, although these effects require experimental validation. ADSV therefore provides a fluid-dynamic framework for mechanically responsive subtidal ventilation that may help manage the changing respiratory mechanics associated with ARDS. Bench and computational studies, followed by preclinical and clinical investigations, are needed to characterize device performance, evaluate regional physiological effects, and establish safety and efficacy in ARDS.
- Open Access
- 5 November 2026
- Published by MDPI AG in Preprints.org
A Study of Fluctuation Growths of Observables in Open Quantum Systems
The rate at which quantum fluctuations of observables can change provides a useful characterization of the dynamical behavior of quantum systems. For closed quantum systems undergoing unitary evolution, previous work has established a general upper bound on the growth rate of the uncertainty of an observable in terms of the standard deviation of its dynamical velocity. This result is closely related to quantum acceleration limits and provides a compact constraint on fluctuation growth. In this work, we will briefly review the closed system results and extend this perspective to open quantum systems, where the state evolves nonunitarily as a consequence of interactions with an environment. The central result is an upper bound on the rate of growth of the uncertainty of an observable that remains valid for general density-matrix dynamics. We develop two complementary derivations. The first introduces a Hermitian pseudo-Hamiltonian describing the local unitary evolution of the eigenvectors of the density matrix. The second, and more general, derivation proceeds directly from the density-matrix derivative and therefore does not require knowledge of the generator of the dynamics. Both approaches lead to the same fluctuation-growth bound. An important practical advantage is that the bound can be evaluated from the observable, the state, and its time derivative without requiring reconstruction of the complete dynamical generator.
- 5 November 2026
- Published by MDPI AG in Preprints.org
Open AccessA Study of Fluctuation Growths of Observables in Open Quantum Systems
The rate at which quantum fluctuations of observables can change provides a useful characterization of the dynamical behavior of quantum systems. For closed quantum systems undergoing unitary evolution, previous work has established a general upper bound on the growth rate of the uncertainty of an observable in terms of the standard deviation of its dynamical velocity. This result is closely related to quantum acceleration limits and provides a compact constraint on fluctuation growth. In this work, we will briefly review the closed system results and extend this perspective to open quantum systems, where the state evolves nonunitarily as a consequence of interactions with an environment. The central result is an upper bound on the rate of growth of the uncertainty of an observable that remains valid for general density-matrix dynamics. We develop two complementary derivations. The first introduces a Hermitian pseudo-Hamiltonian describing the local unitary evolution of the eigenvectors of the density matrix. The second, and more general, derivation proceeds directly from the density-matrix derivative and therefore does not require knowledge of the generator of the dynamics. Both approaches lead to the same fluctuation-growth bound. An important practical advantage is that the bound can be evaluated from the observable, the state, and its time derivative without requiring reconstruction of the complete dynamical generator.