Types
Education, Funder
Locations
Worcester, United States
Relationships

Latest Publications

  • Artificial-Intelligence-Driven Corrosion Analysis Used by the U.S. Army

    by Thomas Considine, Robert Jensen, James Snyder, John Kelley, Nicholas Josselyn, Biao Yin, Elke Rundensteiner, Ziming Zhang

    This article presents an introduction to corrosion testing. It discusses the use of artificial intelligence in corrosion assessment. The article describes the traditional corrosion testing process and corrosion image data processing. It explains baseline nonexpert human corrosion assessment performance. The article provides an overview of deep learning classification models and corrosion segmentation. It also provides a vision for outdoor corrosion assessment and domain adaptation. The article also presents an integrated analytics web dashboard and iOS application.

  • Open Access

    High-Entropy P2-Type Layered Oxide Cathodes for Fast and Durable Sodium-Ion Batteries

    by Jaemin Kim, Panya Thanwisai, Songge Yang, Guangchen Liu, Yu Zhong, Jiahui Hou, Zeyi Yao, Zexin Wang, Sizhan Liu, Yunju Choi, et al.

    Sodium-ion batteries (SIBs) are promising alternatives for large-scale energy storage, but P2-type layered cathodes suffer from structural instability and sluggish Na-ion transport during deep desodiation. Herein, an entropy-driven strategy is presented to stabilize Na-deficient P2-type cathodes by incorporating multiple transition metals into a high-entropy (HE) framework. The increased configurational entropy (1.54R) lowers the Gibbs free energy and stabilizes the layered framework while preserving long-range crystallographic ordering. The resulting compositional disorder modifies the local diffusion energy landscape, reduces Na-ion migration barriers, and enhances transport kinetics. Density functional theory calculations further reveal improved electronic delocalization and charge transfer. The HE cathode exhibits reduced polarization, superior rate capability up to 10 C, and 89.9% capacity retention after 100 cycles. In a full-cell configuration, ∼79% capacity retention is maintained after 400 cycles, whereas the pristine counterpart reaches a similar retention level after only 100 cycles. Structural and spectroscopic analyses further demonstrate suppressed phase transitions, improved oxygen stability and lattice reversibility, and preserved particle connectivity during prolonged cycling. These findings establish configurational entropy as an effective strategy for designing high-performance sodium-ion battery cathodes.

  • Open Access

    A Phase 1 Study of FHD-286, a Dual SMARCA4/SMARCA2 Inhibitor, In Patients With Metastatic Uveal Melanoma

    by Sapna P. Patel, Meredith McKean, Alexander N. Shoushtari, Jose Lutzky, Leonel F. Hernandez-Aya, Shaheer Khan, Richard D. Carvajal, Marlana Orloff, Kamaneh Montazeri, Ellen H.W. Kapiteijn, et al.

    Purpose: The safety, pharmacokinetics, and clinical activity of FHD-286, a SMARCA4/SMARCA2 inhibitor, were evaluated in this multinational, open-label, phase 1, dose escalation study (NCT04879017). Patients and methods: FHD-286 was administered orally once daily (QD) at 2.5, 5, 7.5, and 10mg (continuous dosing) and 10, 15, 17.5, 20, and 22.5mg (1-week-on/1-week-off dosing) to patients with metastatic uveal melanoma (mUM). Results: Seventy-three patients received at least one dose of FHD-286. Six (8.2%) patients experienced dose-limiting toxicities: rash (3 patients) and keratitis, muscular weakness, increased alanine aminotransferase, and thrombocytopenia (1 patient each). The maximum tolerated doses were 7.5mg QD continuous and 15mg QD intermittent. FHD-286 exposure increased with dose and accumulated with QD dosing. One (1.4%) patient achieved a partial response. Conclusion: In this Phase 1 dose-finding study, dual SMARCA4/SMARCA2 inhibition with FHD-286 was associated with a manageable toxicity profile at clinically active doses in patients with mUM. Combinations with other active agents, such as immune checkpoint inhibitors, may be required to achieve higher objective response rates.

  • Open Access

    Genetic circuit design across species and contexts: progress and future directions

    by Alexandria J. Adams, Eric M. Young

    Synthetic biology enables programmable control of microbial behavior. This has diverse applications across many sectors of the economy. For nearly a quarter century, synthetic biologists have reported ever more powerful and complex genetic systems in the model bacterium Escherichia coli . This has been driven by composable parts that perform as expected in well-defined laboratory conditions, which creates a positive feedback loop of increasing design complexity. While impressive, composability within one host does not by itself enable portability–predictably moving functional designs between host organisms and conditions. Yet, portability is essential for real-world applications. The lack of portability limits current practice - essentially circuits are re-engineered to suit each new host and context. However, a growing body of recent work has hinted that there may be generalizable rules for transferring parts and designs from E. coli to other bacteria. Thus, this review describes recent advances in the design and implementation of genetic circuits in diverse bacterial hosts and environmental conditions, highlighting key considerations for a new era of engineering portable genetic designs.

  • Open Access

    Patient-Aware Self-Supervised Contrastive Learning for Passive Assessment of Patient-Reported Knee Osteoarthritis Pain from Wearable Free-Living Activity Counts

    by Wafaa Salem Almuhammadi, Emmanuel Agu

    Accurate assessment of knee osteoarthritis (KOA) pain is critical to inform treatments. KOA pain affects physical activity (PA) and daily movement, offering opportunities for objective assessment. However, limited availability of well-annotated pain data and substantial variability between patients’ daily activity patterns remain barriers to machine learning for PA-based pain assessment. Large-scale, unlabeled PA sensor data are abundant, presenting an opportunity for self-supervised learning. In this paper, we propose Col-KOApain, a patient-aware, self-supervised contrastive learning framework for patient-reported KOA pain-status classification from wearable accelerometer activity counts. To improve pain-status classification, Col-KOApain encourages consistency between complementary time–frequency augmented representations of the same activity signal. Col-KOApain employs a hybrid Transformer–CNN encoder, patient-aware regularization, and a fusion-based time–frequency contrastive loss while preserving within-patient multi-day structure. Col-KOApain was evaluated using Osteoarthritis Initiative (OAI: 3,318 visit records) and National Health and Nutrition Examination Survey (NHANES: 392 participants) datasets, with KOOS Pain-derived labels in OAI and self-reported knee-pain labels in NHANES. Binary Macro-F1 scores reached 86.9%, 83.5%, and 79.8% under within-cohort, temporal-transfer, and cross-dataset settings, respectively. We also evaluated 3-class and exploratory 4-class pain-status tasks. Our results highlight Col-KOApain’s potential for KOA pain-status assessment in real-world scenarios with limited labeled data.

  • Open Access

    Decoupling bulk stiffness and pore size in 3D rat tail collagen I matrices

    by Theadora Vessella, Qi Wen, Hong Susan Zhou

    The interplay between extracellular matrix mechanics and the tumor microenvironment is increasingly recognized as a key driver of cancer progression. Three-dimensional (3D) collagen I culture systems provide more physiologically relevant environments than traditional two-dimensional cultures, yet seperately controlling the structural and mechanical features of 3D matrices remains challenging due to their inherent interdependence. Here, we present a collagen-based approach to decouple bulk stiffness and pore size by varying collagen concentration and polymerization temperature. Collagen concentration was varied to modulate bulk storage modulus, while polymerization temperature was adjusted to alter pore dimensions at comparable collagen concentrations. Using this approach, we generated 3D Collagen I matrices with bulk storage moduli of approximately 80, 228, and 360 Pa while maintaining a similar median pore sizes near 2.5 µ m. Conversely, 1.5 mg ml −1 collagen, median pore size varied from approximately 2.5–3.1 µ m while bulk storage modulus ramined near 80 Pa, whereas at 3.5 mg ml −1 collagen, pore size varied from approximately 2.0–2.4 µ m while bulk storage modulus remained near 350 Pa. We further evaluated the responses of MCF-10A epithelial cells and MDA-MB-231 metastatic breast cancer cells to matrices spanning these structural and mechanical conditions. Although the changes in pore size within each stiffness range were modest, they were associated with measurable and statistical differences in cell morphology. These findings demonstrate that even modest changes in collagen network architecture can produce measurable differences in cellular behavior under comparable bulk mechanical conditions, highlighting the importance of considering matrix structure in addition to stiffness when investigating cell-matrix interactions.

  • Open Access

    Bamboo as a cost-effective feedstock for production of low carbon transportation fuels

    by Timothy M. Woodard, Charles M. Cai, James Walters, Michael T. Timko

    From bamboo to biofuel, no catalyst needed: a 30-mile supply radius could feed an HTL biorefinery making 299 million gallons of diesel per year for as little as a projected $2.75 per gge and 3.5 g CO 2 -eq per MJ.

  • Open Access

    EEG Source Localization with High-Resolution 40-Tissue Head Models: A Comparative Study with MEG during Photic Driving

    by Guillermo Núñez Ponasso, Derek A. Drumm, Hannes Oppermann, Gregory M. Noetscher, Burkhard Maess, Thomas R. Knösche, Jens Haueisen, Sergey N. Makaroff

    While MEG source localization pipelines often employ head models of one single compartment with homogeneous conductivity, researchers and clinicians use at least 3 different layers in head models for EEG source localization. Recent AI-based segmentation makes it possible to generate individualized head models with 40 high-resolution, non-nested tissues. We present a pipeline that can make use of, and test, these highly realistic models for EEG source localization: with the boundary element fast multipole method (BEM-FMM), we compute transcranial electric stimulation (TES) solutions on the full 40-tissue geometry and use them reciprocally to obtain the EEG leadfields. Our approach runs on a single modest workstation, requiring approximately 4.5 min per EEG channel for a mesh of about one million elements at a relative residual of 10 − 4 . We applied the pipeline to six participants undergoing intermittent photic stimulation at half their individual alpha peak frequency, comparing 61-channel EEG source localizations from 40-tissue and 5-layer models with each other and with localizations from simultaneously recorded MEG. We further compared noiseless synthetic EEG topographies of the two models across the entire cortex. The two models produced highly consistent EEG source localizations (weighted relative difference below 3%), both in close agreement with the MEG localizations within the visual cortex. The synthetic topographies also agreed closely, with differences scaling approximately linearly with the angle between the source orientations of the two models, underscoring the importance of accurate source normals in fixed-orientation source models. These results establish 40-tissue models as a practical and robust basis for EEG source localization, and open the way to applications where nested geometries cannot represent the anatomy, such as infants or patients with skull defects, injuries, or tumors.