MACOM (United States)

Type
CompanyLocations
Lowell, United StatesRelationships
Latest Publications
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 25 (5) , 136-145
IMS2024 20th Anniversary of the Student Design Competition
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 25 (5) , 136-145
IMS2024 20th Anniversary of the Student Design Competition
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 25 (5) , 171-174
MP3: Capitalizing Across the Spectrum
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave Magazine
- Vol. 25 (5) , 171-174
MP3: Capitalizing Across the Spectrum
Provides society information that may include news, reviews or technical notes that should be of interest to practitioners and researchers.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Correction to Faulty Traditional Unintentionally Bayesian Formula for Device Reliability Estimation
This paper presents a fundamental correction to a decades-long standing traditional formula for computing confidence bounds on failure rates estimated from reliability life test evaluations. The chi-squared based formula with degrees of freedom set to twice the number of observed failures plus two imprecisely overestimates the failure rate confidence bound by failing to place the observed maximum likelihood estimate hazard function value at the median of the posterior distribution. Correcting this formula involves shifting from Bayes-Laplace prior with unity adder to the neutral Kerman prior with adder one-third. The repaired formula requires expression in native Gamma distribution form since the erstwhile equivalent degrees of freedom for chi-squared representation is disallowed as it is non-integer. Improvements in the accuracy of the confidence bound are more marked for lower numbers of life test evaluation failures.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Correction to Faulty Traditional Unintentionally Bayesian Formula for Device Reliability Estimation
This paper presents a fundamental correction to a decades-long standing traditional formula for computing confidence bounds on failure rates estimated from reliability life test evaluations. The chi-squared based formula with degrees of freedom set to twice the number of observed failures plus two imprecisely overestimates the failure rate confidence bound by failing to place the observed maximum likelihood estimate hazard function value at the median of the posterior distribution. Correcting this formula involves shifting from Bayes-Laplace prior with unity adder to the neutral Kerman prior with adder one-third. The repaired formula requires expression in native Gamma distribution form since the erstwhile equivalent degrees of freedom for chi-squared representation is disallowed as it is non-integer. Improvements in the accuracy of the confidence bound are more marked for lower numbers of life test evaluation failures.
- Open Access
- 28 July 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (8) , 1941
Low-Cost 400 Gbps DR4 Silicon Photonics Transmitter for Short-Reach Datacenter Application
Targeting high-speed, low-cost, short-reach intra-datacenter connections, we designed and tested an integrated silicon photonic circuit as a transmitter engine. This engine can be packaged into an optical transceiver module which meets the QSFP-DD Form Factor, together with other electrical/optical components. We first present the design and performance of a high-speed silicon modulator, which had a 3-dB EO bandwidth of >40 GHz and an ER of >5 dB. We then incorporated the engine onto a test board and injected a 53.125 Gbaud PAM4 signal. Clear eye patterns were observed at the receiver with TDECQ ~3 dB for all four lanes.
- 28 July 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (8) , 1941
Open AccessLow-Cost 400 Gbps DR4 Silicon Photonics Transmitter for Short-Reach Datacenter Application
Targeting high-speed, low-cost, short-reach intra-datacenter connections, we designed and tested an integrated silicon photonic circuit as a transmitter engine. This engine can be packaged into an optical transceiver module which meets the QSFP-DD Form Factor, together with other electrical/optical components. We first present the design and performance of a high-speed silicon modulator, which had a 3-dB EO bandwidth of >40 GHz and an ER of >5 dB. We then incorporated the engine onto a test board and injected a 53.125 Gbaud PAM4 signal. Clear eye patterns were observed at the receiver with TDECQ ~3 dB for all four lanes.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Multi-Rate 25/12.5/10-Gb/s Burst-Mode Upstream Transmission Based on a 10G Burst-Mode ROSA with Digital Equalization Achieving 20dB Dynamic Range and sub-100ns Recovery Time
We experimentally demonstrate multi-rate burst-mode transmission at 25, 12.5 and 10Gb/s using a 10GHz-class burst-mode receiver optical sub-assembly (ROSA), respectively achieving receiver sensitivities of −27.7, −31, and −32.1dBm after 20-km SSMF transmission at 1E-2 BER, all with 20-dB dynamic range and 92-ns burst recovery time.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Multi-Rate 25/12.5/10-Gb/s Burst-Mode Upstream Transmission Based on a 10G Burst-Mode ROSA with Digital Equalization Achieving 20dB Dynamic Range and sub-100ns Recovery Time
We experimentally demonstrate multi-rate burst-mode transmission at 25, 12.5 and 10Gb/s using a 10GHz-class burst-mode receiver optical sub-assembly (ROSA), respectively achieving receiver sensitivities of −27.7, −31, and −32.1dBm after 20-km SSMF transmission at 1E-2 BER, all with 20-dB dynamic range and 92-ns burst recovery time.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 218-221
Surface Wave Technique at Millimeter Waveband for Semiconductor Testing by Photoexcitation
A new surface wave technique at millimeter waveband 53-225GHz has been developed for non-contact, non-destructive testing of semiconductors using photoexcitation. Both positive and negative signal polarities are observed for semiconductor samples and metal-semiconductor structures. The scheme of experimental setup is presented. Preliminary experimental results are illustrated and discussed.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 218-221
Surface Wave Technique at Millimeter Waveband for Semiconductor Testing by Photoexcitation
A new surface wave technique at millimeter waveband 53-225GHz has been developed for non-contact, non-destructive testing of semiconductors using photoexcitation. Both positive and negative signal polarities are observed for semiconductor samples and metal-semiconductor structures. The scheme of experimental setup is presented. Preliminary experimental results are illustrated and discussed.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Characterization of Silicon Nitride Capping Dielectrics on AlGaN/GaN/Silicon Substrate HEMT Structures with a Mercury Probe
The characterization of High Electron Mobility Transistor (HEMT) structures is important for predicting device behavior, monitoring and developing processes and improving performance. This also includes measuring the quality of the top dielectric capping layer. The top capping dielectric and its' associated charges both in the dielectric and at the interface can induce shifts and instabilities in the HEMT device pinch-off voltage. In this paper, a highly repeatable and accurate, small area mercury gate is used to measure critical HEMT parameters earlier in the process and prior to final device formation.
- 1 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Characterization of Silicon Nitride Capping Dielectrics on AlGaN/GaN/Silicon Substrate HEMT Structures with a Mercury Probe
The characterization of High Electron Mobility Transistor (HEMT) structures is important for predicting device behavior, monitoring and developing processes and improving performance. This also includes measuring the quality of the top dielectric capping layer. The top capping dielectric and its' associated charges both in the dielectric and at the interface can induce shifts and instabilities in the HEMT device pinch-off voltage. In this paper, a highly repeatable and accurate, small area mercury gate is used to measure critical HEMT parameters earlier in the process and prior to final device formation.
- 12 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 66 (1) , 330-336
The Impact of Temperature on GaN/Si HEMTs Under RF Operation Using Gate Resistance Thermometry
Several optical and electrical methods have been developed to thermally characterize GaN high-electron mobility transistors (HEMTs) under DC operation. Gate resistance thermometry (GRT) has proven to be an inexpensive and reliable method to estimate the peak temperature. The complex Joule heating profile of a HEMT, however, is highly bias dependent, and its temperature profile under RF conditions may vary compared to the profile generated under DC operation. Evaluating the thermal performance of HEMTs under RF operation is thus necessary to quantify any differences between these two modes of operation. Implementing a differential probe, this paper highlights the capability of using GRT to measure accurately the temperature of GaN/Si HEMTs under RF operation. A larger gate-to-gate spacing is shown to decrease the overall temperature rise, while a linear correlation is found between the power-added efficiency and the junction temperature. The effect of the baseplate temperature on the device's thermal performance both under steady-state and RF operations is presented. Overall, at a given power density and baseplate temperature, the RF temperature rise is shown to appear lower than its equivalent temperature under DC biasing.
- 12 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 66 (1) , 330-336
The Impact of Temperature on GaN/Si HEMTs Under RF Operation Using Gate Resistance Thermometry
Several optical and electrical methods have been developed to thermally characterize GaN high-electron mobility transistors (HEMTs) under DC operation. Gate resistance thermometry (GRT) has proven to be an inexpensive and reliable method to estimate the peak temperature. The complex Joule heating profile of a HEMT, however, is highly bias dependent, and its temperature profile under RF conditions may vary compared to the profile generated under DC operation. Evaluating the thermal performance of HEMTs under RF operation is thus necessary to quantify any differences between these two modes of operation. Implementing a differential probe, this paper highlights the capability of using GRT to measure accurately the temperature of GaN/Si HEMTs under RF operation. A larger gate-to-gate spacing is shown to decrease the overall temperature rise, while a linear correlation is found between the power-added efficiency and the junction temperature. The effect of the baseplate temperature on the device's thermal performance both under steady-state and RF operations is presented. Overall, at a given power density and baseplate temperature, the RF temperature rise is shown to appear lower than its equivalent temperature under DC biasing.
- 27 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Semiconductor Manufacturing
- Vol. 31 (4) , 454-459
High Volume Manufacturing of Lasers and Photo-Diodes on 4 Inch InP in GaAs IC Wafer Fabrication Facility
The massive growth of data traffic generated by human and machine activity has significantly increased the demand for photonics products for optical communications. In order to meet the current market demand at lower price points, it is necessary to increase the production volume and the wafer size for printing more devices. For this reason, high-volume manufacturing processes for lasers and photodiodes were developed using the existing equipment in a GaAs IC wafer fabrication facility, without a major capital investment. A variety of highly reliable, high-performance directly modulated edge emitting lasers and front illuminated photodiodes were manufactured on 4 inch InP substrates.
- 27 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Semiconductor Manufacturing
- Vol. 31 (4) , 454-459
High Volume Manufacturing of Lasers and Photo-Diodes on 4 Inch InP in GaAs IC Wafer Fabrication Facility
The massive growth of data traffic generated by human and machine activity has significantly increased the demand for photonics products for optical communications. In order to meet the current market demand at lower price points, it is necessary to increase the production volume and the wafer size for printing more devices. For this reason, high-volume manufacturing processes for lasers and photodiodes were developed using the existing equipment in a GaAs IC wafer fabrication facility, without a major capital investment. A variety of highly reliable, high-performance directly modulated edge emitting lasers and front illuminated photodiodes were manufactured on 4 inch InP substrates.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1032-1035
A Novel CAD Probe for Bidirectional Impedance and Stability Analysis
Bidirectional impedance probes such as the ADS SProbe2 (Keysight) and the MWO Gprobe2 (AWR) suffer from a loss of accuracy when subjected to feedback across their terminals. Being originally developed to facilitate stability analysis, these traditional probes are actually based on an incorrect conceptual model that lacks the generality needed to provide accurate results when embedded within networks with potentially high levels of feedback. In realistic networks, there can exist layers of intentional and unintentional feedback paths around your active devices and across the probes used to compute in-situ bidirectional impedances and assess local stability. It is critical, therefore, that the bidirectional impedance probe is capable of providing accurate results under the most extreme feedback conditions. To this end, a novel CAD probe has been developed that is based on a simple, but general model of feedback and is accurate when subjected to arbitrary levels of feedback across its terminals and can be used to accurately determine both in-situ bidirectional impedances and local loop stability.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1032-1035
A Novel CAD Probe for Bidirectional Impedance and Stability Analysis
Bidirectional impedance probes such as the ADS SProbe2 (Keysight) and the MWO Gprobe2 (AWR) suffer from a loss of accuracy when subjected to feedback across their terminals. Being originally developed to facilitate stability analysis, these traditional probes are actually based on an incorrect conceptual model that lacks the generality needed to provide accurate results when embedded within networks with potentially high levels of feedback. In realistic networks, there can exist layers of intentional and unintentional feedback paths around your active devices and across the probes used to compute in-situ bidirectional impedances and assess local stability. It is critical, therefore, that the bidirectional impedance probe is capable of providing accurate results under the most extreme feedback conditions. To this end, a novel CAD probe has been developed that is based on a simple, but general model of feedback and is accurate when subjected to arbitrary levels of feedback across its terminals and can be used to accurately determine both in-situ bidirectional impedances and local loop stability.