Citizen (Japan)

Type
CompanyLocations
Nishi-Tokyo-shi, JapanLatest Publications
- Open Access
- 1 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026005-10
Optical coherence tomography with a 2.8-mm beam diameter and sensorless defocus and astigmatism correction
Optical coherence tomography (OCT) is a noninvasive, high-resolution optical imaging technique that is based on low coherence interferometry, and it is highly useful for generating cross-sectional images of turbid media. The first generation of OCT was in the time domain,1 with depth scan rates up to about 1 kHz, making it difficult to perform in vivo imaging of biological samples such as the human retina without motion artifacts. The introduction of Fourier-domain optical coherence tomography (FD-OCT) has improved the imaging speed and sensitivity over time-domain optical coherence tomography (TD-OCT).2,3 While the first spectral-domain OCT systems operated at depth scan rates of around 25 kHz, current systems can operate at speeds of 70 kHz or higher. High acquisition rates come with one penalty: the shorter acquisition time per depth scan causes a drop in sensitivity. To maintain image quality, one option is to increase the power that is incident on the sample. The ANSI safety rules for safe use of lasers limit the amount of light that can be sent into the eye.4 Another option to improve image quality is to increase the photon collection efficiency of the sample arm. This can be achieved by using a larger beam size than the beam diameter that is used in the sample arm of standard OCT instruments. Merits of a larger beam size are a decreased speckle size and improved lateral resolution, which is limited by the diffraction limit set by the beam size, the focal length of the eye, and the wavelength of the light. While OCT permits independent control of its lateral and axial resolutions, an increased numerical aperture limits the confocal depth of the system, which affects the image quality at depths above and below the beam waist. Furthermore, with increasing beam diameter, the aberrations induced by the eye increase as well.5 To obtain these advantages and minimize the disadvantages caused by a large beam diameter, aberration correction is essential.- 1 February 2017
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (2) , 026005-10
Open AccessOptical coherence tomography with a 2.8-mm beam diameter and sensorless defocus and astigmatism correction
Optical coherence tomography (OCT) is a noninvasive, high-resolution optical imaging technique that is based on low coherence interferometry, and it is highly useful for generating cross-sectional images of turbid media. The first generation of OCT was in the time domain,1 with depth scan rates up to about 1 kHz, making it difficult to perform in vivo imaging of biological samples such as the human retina without motion artifacts. The introduction of Fourier-domain optical coherence tomography (FD-OCT) has improved the imaging speed and sensitivity over time-domain optical coherence tomography (TD-OCT).2,3 While the first spectral-domain OCT systems operated at depth scan rates of around 25 kHz, current systems can operate at speeds of 70 kHz or higher. High acquisition rates come with one penalty: the shorter acquisition time per depth scan causes a drop in sensitivity. To maintain image quality, one option is to increase the power that is incident on the sample. The ANSI safety rules for safe use of lasers limit the amount of light that can be sent into the eye.4 Another option to improve image quality is to increase the photon collection efficiency of the sample arm. This can be achieved by using a larger beam size than the beam diameter that is used in the sample arm of standard OCT instruments. Merits of a larger beam size are a decreased speckle size and improved lateral resolution, which is limited by the diffraction limit set by the beam size, the focal length of the eye, and the wavelength of the light. While OCT permits independent control of its lateral and axial resolutions, an increased numerical aperture limits the confocal depth of the system, which affects the image quality at depths above and below the beam waist. Furthermore, with increasing beam diameter, the aberrations induced by the eye increase as well.5 To obtain these advantages and minimize the disadvantages caused by a large beam diameter, aberration correction is essential. - 4 November 2016
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 55 (12) , 122202
Parallel generation of multiple first-order vector beams with a polarization grating and a q-plate device
Vector beams, usually generated using q-plates, are of interest because their polarization state varies spatially. In general, the q-plate performance is examined by illuminating the device and detecting the output beam with polarization states on the 6 cardinal points on the zero-order Poincaré sphere, requiring a total of 36 separate measurements. In this work we present a powerful technique to generate arbitrary vector beams in parallel, thus reducing the number of measurements required. We begin with a programmable polarization diffraction grating capable to generate an arbitrary number of diffraction orders with defined polarization states selected at will. Then we combine this grating with a segmented q-plate device with q = 1/2 value. Using this combination, the parallel generation of six arbitrary first-order vector beams is achieved in a single shot. Therefore, the analysis of these beams can be greatly reduced.
- 4 November 2016
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 55 (12) , 122202
Parallel generation of multiple first-order vector beams with a polarization grating and a q-plate device
Vector beams, usually generated using q-plates, are of interest because their polarization state varies spatially. In general, the q-plate performance is examined by illuminating the device and detecting the output beam with polarization states on the 6 cardinal points on the zero-order Poincaré sphere, requiring a total of 36 separate measurements. In this work we present a powerful technique to generate arbitrary vector beams in parallel, thus reducing the number of measurements required. We begin with a programmable polarization diffraction grating capable to generate an arbitrary number of diffraction orders with defined polarization states selected at will. Then we combine this grating with a segmented q-plate device with q = 1/2 value. Using this combination, the parallel generation of six arbitrary first-order vector beams is achieved in a single shot. Therefore, the analysis of these beams can be greatly reduced.
- 27 September 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 99500L-99500L-9
Physical and encoded Q-plates for the generation of switchable vector beams
- 27 September 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 99500L-99500L-9
Physical and encoded Q-plates for the generation of switchable vector beams
- Open Access
- 13 September 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (12) , 121503-10
Transmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy
Confocal laser scanning microscopy (LSM) has enabled impressive three-dimensional fluorescence imaging. Furthermore, in the case of two-photon excitation LSM (2P-LSM), fluorescent molecules are excited within a very small focal volume.1,2 This high degree of localization in the 2P method enables cross-sectional fluorescence imaging in the absence of a confocal aperture. In addition, near-infrared laser light used for 2P processes is barely absorbed by or scattered in a biospecimen. 2P-LSM can three-dimensionally visualize deep regions within a biospecimen because of these advantages. However, a mismatch of refractive indices in an optical path can induce wavefront aberrations, which degrades the spatial resolution and fluorescence signal of an image.3,4 Spatial light modulators have been shown to correct these aberrations and improve the image quality of biospecimens.5,6 However, these reflective spatial light modulators require the user to change the basic design of an optical path in a conventional microscope.
- 13 September 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (12) , 121503-10
Open AccessTransmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy
Confocal laser scanning microscopy (LSM) has enabled impressive three-dimensional fluorescence imaging. Furthermore, in the case of two-photon excitation LSM (2P-LSM), fluorescent molecules are excited within a very small focal volume.1,2 This high degree of localization in the 2P method enables cross-sectional fluorescence imaging in the absence of a confocal aperture. In addition, near-infrared laser light used for 2P processes is barely absorbed by or scattered in a biospecimen. 2P-LSM can three-dimensionally visualize deep regions within a biospecimen because of these advantages. However, a mismatch of refractive indices in an optical path can induce wavefront aberrations, which degrades the spatial resolution and fluorescence signal of an image.3,4 Spatial light modulators have been shown to correct these aberrations and improve the image quality of biospecimens.5,6 However, these reflective spatial light modulators require the user to change the basic design of an optical path in a conventional microscope.
- 22 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9912, 99122Z
Novel diffraction gratings for next generation spectrographs with high spectral dispersion
As a transmission grating, a surface-relief (SR) grating with sawtooth shaped ridges and volume phase holographic (VPH) grating are widely used for instruments of astronomical observations. However the SR grating is difficult to achieve high diffraction efficiency at high angular dispersion, and the VPH grating has low diffraction efficiency in high diffraction orders. We propose novel gratings that solve these problems. We introduce the hybrid grism which combines a high refractive index prism with a replicated transmission grating, which has sawtooth shaped ridges of an acute apex angle. The birefringence VPH (B-VPH) grating which contains an anisotropic medium, such as a liquid crystal, achieves diffraction efficiency up to 100% at the first diffraction order for natural polarization and for circular polarization. The quasi-Bragg (QB) grating which consists of long rectangular mirrors aligned in parallel precisely, like a window blind, achieves diffraction efficiency of 60% or more in higher than the 4th diffraction order. The volume binary (VB) grating with narrow grooves also achieves diffraction efficiency of 60% or more in higher than the 6th diffraction order. The reflector facet transmission (RFT) grating which is a SR grating with sawtooth shaped ridges of an acute apex angle achieves diffraction efficiency up to 80% in higher than the 4th diffraction order.
- 22 July 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9912, 99122Z
Novel diffraction gratings for next generation spectrographs with high spectral dispersion
As a transmission grating, a surface-relief (SR) grating with sawtooth shaped ridges and volume phase holographic (VPH) grating are widely used for instruments of astronomical observations. However the SR grating is difficult to achieve high diffraction efficiency at high angular dispersion, and the VPH grating has low diffraction efficiency in high diffraction orders. We propose novel gratings that solve these problems. We introduce the hybrid grism which combines a high refractive index prism with a replicated transmission grating, which has sawtooth shaped ridges of an acute apex angle. The birefringence VPH (B-VPH) grating which contains an anisotropic medium, such as a liquid crystal, achieves diffraction efficiency up to 100% at the first diffraction order for natural polarization and for circular polarization. The quasi-Bragg (QB) grating which consists of long rectangular mirrors aligned in parallel precisely, like a window blind, achieves diffraction efficiency of 60% or more in higher than the 4th diffraction order. The volume binary (VB) grating with narrow grooves also achieves diffraction efficiency of 60% or more in higher than the 6th diffraction order. The reflector facet transmission (RFT) grating which is a SR grating with sawtooth shaped ridges of an acute apex angle achieves diffraction efficiency up to 80% in higher than the 4th diffraction order.
- 15 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9717, 97171N
Transmissive liquid-crystal device correcting primary coma aberration and astigmatism in laser scanning microscopy
Laser scanning microscopy allows 3D cross-sectional imaging inside biospecimens. However, certain aberrations produced can degrade the quality of the resulting images. We previously reported a transmissive liquid-crystal device that could compensate for the predominant spherical aberrations during the observations, particularly in deep regions of the samples. The device, inserted between the objective lens and the microscope revolver, improved the image quality of fixed-mouse-brain slices that were observed using two-photon excitation laser scanning microscopy, which was originally degraded by spherical aberration. In this study, we developed a transmissive device that corrects primary coma aberration and astigmatism, motivated by the fact that these asymmetric aberrations can also often considerably deteriorate image quality, even near the sample surface. The device's performance was evaluated by observing fluorescent beads using single-photon excitation laser scanning microscopy. The fluorescence intensity in the image of the bead under a cover slip tilted in the y-direction was increased by 1.5 times after correction by the device. Furthermore, the y- and z-widths of the imaged bead were reduced to 66% and 65%, respectively. On the other hand, for the imaged bead sucked into a glass capillary in the longitudinal x-direction, correction with the device increased the fluorescence intensity by 2.2 times compared to that of the aberrated image. In addition, the x-, y-, and z-widths of the bead image were reduced to 75%, 53%, and 40%, respectively. Our device successfully corrected several asymmetric aberrations to improve the fluorescent signal and spatial resolution, and might be useful for observing various biospecimens.
- 15 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9717, 97171N
Transmissive liquid-crystal device correcting primary coma aberration and astigmatism in laser scanning microscopy
Laser scanning microscopy allows 3D cross-sectional imaging inside biospecimens. However, certain aberrations produced can degrade the quality of the resulting images. We previously reported a transmissive liquid-crystal device that could compensate for the predominant spherical aberrations during the observations, particularly in deep regions of the samples. The device, inserted between the objective lens and the microscope revolver, improved the image quality of fixed-mouse-brain slices that were observed using two-photon excitation laser scanning microscopy, which was originally degraded by spherical aberration. In this study, we developed a transmissive device that corrects primary coma aberration and astigmatism, motivated by the fact that these asymmetric aberrations can also often considerably deteriorate image quality, even near the sample surface. The device's performance was evaluated by observing fluorescent beads using single-photon excitation laser scanning microscopy. The fluorescence intensity in the image of the bead under a cover slip tilted in the y-direction was increased by 1.5 times after correction by the device. Furthermore, the y- and z-widths of the imaged bead were reduced to 66% and 65%, respectively. On the other hand, for the imaged bead sucked into a glass capillary in the longitudinal x-direction, correction with the device increased the fluorescence intensity by 2.2 times compared to that of the aberrated image. In addition, the x-, y-, and z-widths of the bead image were reduced to 75%, 53%, and 40%, respectively. Our device successfully corrected several asymmetric aberrations to improve the fluorescent signal and spatial resolution, and might be useful for observing various biospecimens.
- 15 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9739, 973914
Propagation properties of quantized Laguerre-Gaussian beams in atmospheric turbulence
Effect of scintillations is serious problems in optical systems which require the atmospheric propagation, the optimization of optical system to minimize the effects of scintillation have been examined using the simulation of propagation in atmospheric turbulence. The analytic studies of scintillation index of LG beams show that LG beams have less scintillation than Gaussian beams. However, in these researches, the diameter of receiving aperture was set as point receiver without considering the effects of aperture averaging, which is phenomenon that reduced scintillations over finite aperture. In this paper, considering size of a receiving aperture, the propagation losses and the scintillation index of LG beams are simulated. Also, for practical applications, propagation properties of "quantized" LG(5,1) beams simulated. As a result of the examination, the propagation losses and the scintillation index of LG beams is smaller than those of Gaussian beams. By applying LG beams for optical wireless communications, it is expected to improve better the effect of scintillations than using Gaussian beams. The result is that the scintillation index of quantized LG beams is equal to those of LG beams, and it suggested that quantized LG beams can be treat the quantized LG beams the same as LG beams.
- 15 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9739, 973914
Propagation properties of quantized Laguerre-Gaussian beams in atmospheric turbulence
Effect of scintillations is serious problems in optical systems which require the atmospheric propagation, the optimization of optical system to minimize the effects of scintillation have been examined using the simulation of propagation in atmospheric turbulence. The analytic studies of scintillation index of LG beams show that LG beams have less scintillation than Gaussian beams. However, in these researches, the diameter of receiving aperture was set as point receiver without considering the effects of aperture averaging, which is phenomenon that reduced scintillations over finite aperture. In this paper, considering size of a receiving aperture, the propagation losses and the scintillation index of LG beams are simulated. Also, for practical applications, propagation properties of "quantized" LG(5,1) beams simulated. As a result of the examination, the propagation losses and the scintillation index of LG beams is smaller than those of Gaussian beams. By applying LG beams for optical wireless communications, it is expected to improve better the effect of scintillations than using Gaussian beams. The result is that the scintillation index of quantized LG beams is equal to those of LG beams, and it suggested that quantized LG beams can be treat the quantized LG beams the same as LG beams.
- 1 March 2016
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 55 (3) , 030502
Generation of vector beams at 1550 nm telecommunications wavelength using a segmented q -plate
We present the use of a -plate device operating at the 1550 nm telecommunications wavelength. A prototype liquid-crystal device from Citizen Holdings Co. is demonstrated to be useful for the generation of vector beams and orbital angular momentum transfer at this important wavelength.- 1 March 2016
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 55 (3) , 030502
Generation of vector beams at 1550 nm telecommunications wavelength using a segmented q -plate
We present the use of a -plate device operating at the 1550 nm telecommunications wavelength. A prototype liquid-crystal device from Citizen Holdings Co. is demonstrated to be useful for the generation of vector beams and orbital angular momentum transfer at this important wavelength.- 16 December 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (1) , 13-16
Performance of a q-plate tunable retarder in reflection for the switchable generation of both first- and second-order vector beams
We examine the performance of a tunable liquid crystal -plate in a reflective geometry. When the device is tuned to a half-wave retardance, it operates as a -plate with twice the value () by adding a quarter-wave retarder between the mirror and the -plate. However, when the device is tuned to a quarter-wave retardance, it acts as the original -plate without the retarder. Experimental results are shown. Using an input tunable polarization state generator, the system allows the switchable production of all states on both the first- and second-order Poincaré spheres.- 16 December 2015
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (1) , 13-16
Performance of a q-plate tunable retarder in reflection for the switchable generation of both first- and second-order vector beams
We examine the performance of a tunable liquid crystal -plate in a reflective geometry. When the device is tuned to a half-wave retardance, it operates as a -plate with twice the value () by adding a quarter-wave retarder between the mirror and the -plate. However, when the device is tuned to a quarter-wave retardance, it acts as the original -plate without the retarder. Experimental results are shown. Using an input tunable polarization state generator, the system allows the switchable production of all states on both the first- and second-order Poincaré spheres.- 9 November 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (32) , 9583-9590
Analysis of a segmented q-plate tunable retarder for the generation of first-order vector beams
In this work we study a prototype -plate segmented tunable liquid crystal retarder device. It shows a large modulation range ( rad for a wavelength of 633 nm and near for 1550 nm) and a large clear aperture of one inch diameter. We analyze the operation of the -plate in terms of Jones matrices and provide different matrix decompositions useful for its analysis, including the polarization transformations, the effect of the tunable phase shift, and the effect of quantization levels (the device is segmented in 12 angular sectors). We also show a very simple and robust optical system capable of generating all polarization states on the first-order Poincaré sphere. An optical polarization rotator and a linear retarder are used in a geometry that allows the generation of all states in the zero-order Poincaré sphere simply by tuning two retardance parameters. We then use this system with the -plate device to directly map an input arbitrary state of polarization to a corresponding first-order vectorial beam. This optical system would be more practical for high speed and programmable generation of vector beams than other systems reported so far. Experimental results are presented.- 9 November 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (32) , 9583-9590
Analysis of a segmented q-plate tunable retarder for the generation of first-order vector beams
In this work we study a prototype -plate segmented tunable liquid crystal retarder device. It shows a large modulation range ( rad for a wavelength of 633 nm and near for 1550 nm) and a large clear aperture of one inch diameter. We analyze the operation of the -plate in terms of Jones matrices and provide different matrix decompositions useful for its analysis, including the polarization transformations, the effect of the tunable phase shift, and the effect of quantization levels (the device is segmented in 12 angular sectors). We also show a very simple and robust optical system capable of generating all polarization states on the first-order Poincaré sphere. An optical polarization rotator and a linear retarder are used in a geometry that allows the generation of all states in the zero-order Poincaré sphere simply by tuning two retardance parameters. We then use this system with the -plate device to directly map an input arbitrary state of polarization to a corresponding first-order vectorial beam. This optical system would be more practical for high speed and programmable generation of vector beams than other systems reported so far. Experimental results are presented.