Masimo (United States)

Types
Company, FunderLocations
Irvine, United StatesRelationships
Latest Publications
- Open Access
- 26 May 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (4) , 1-12
NIRS monitoring during steep trendelenburg in robotic prostatectomy
Robotic-assisted laparoscopic prostatectomy (RALP) requires steep Trendelenburg positioning and CO₂ pneumoperitoneum, which may significantly influence cerebral hemodynamic homeostasis. While postoperative neurological complications are uncommon, there is concern regarding increased intracranial pressure and potential edema during prolonged procedures. Near-infrared spectroscopy (NIRS) allows continuous monitoring of cerebral oxygenation, rSO2 reflects the balance between oxygen delivery and consumption, integrating changes of oxygenated hemoglobin (ΔHbO2) and deoxygenated hemoglobin (ΔHHb). This study aimed to evaluate phase-dependent changes in cerebral oxygenation (rSO₂, ΔO₂Hb, ΔHHb) and optic nerve sheath diameter (ONSD) during RALP, and to assess their temporal correlation. This prospective observational study enrolled forty adult patients (ASA I–III) undergoing RALP in steep Trendelenburg position (30 degrees) at Nuovo Ospedale di Prato, Italy, between November 2024 and May 2025. Cerebral oxygenation was continuously monitored using near-infrared spectroscopy (NIRS). ONSD was measured bilaterally using ultrasound at predefined time points: baseline (T0), 45 min after Trendelenburg positioning (T1), 120 min after Trendelenburg (T2), during vesicourethral anastomosis (T3), and before extubation in neutral position (T4). Pearson correlation coefficients were calculated to assess the association between NIRS-derived parameters and ONSD changes. Compared with baseline, Trendelenburg positioning was associated with significant phase-dependent changes in cerebral oxygenation and hemoglobin-derived parameters. rSO₂ and ΔO₂Hb increased during early and prolonged Trendelenburg phases, peaking during vesicourethral anastomosis (T3), and partially decreased after return to supine position (T4). ΔHHb demonstrated a progressive increase during later intraoperative phases, reaching highest values at T3 and T4. ONSD increased progressively across phases on both sides (right: 3.79 ± 0.36 mm at T0 to 4.59 ± 0.47 mm at T3; left: 3.80 ± 0.42 mm to 4.73 ± 0.47 mm). Correlation analysis demonstrated a moderate-to-strong association between ΔHHb and ONSD (right: r = 0.63, p < 10⁻¹⁶; left: r = 0.63, p < 10⁻¹⁶), supporting temporal coupling between cerebral deoxygenated hemoglobin accumulation and optic nerve sheath expansion. This study demonstrates distinct phase-dependent cerebral oxygenation patterns during RALP. The late-phase increase in ΔHHb occurring alongside ONSD enlargement may reflect cerebral venous congestion, a mechanism potentially involved in cerebral edema development during prolonged steep Trendelenburg positioning.
- 26 May 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (4) , 1-12
Open AccessNIRS monitoring during steep trendelenburg in robotic prostatectomy
Robotic-assisted laparoscopic prostatectomy (RALP) requires steep Trendelenburg positioning and CO₂ pneumoperitoneum, which may significantly influence cerebral hemodynamic homeostasis. While postoperative neurological complications are uncommon, there is concern regarding increased intracranial pressure and potential edema during prolonged procedures. Near-infrared spectroscopy (NIRS) allows continuous monitoring of cerebral oxygenation, rSO2 reflects the balance between oxygen delivery and consumption, integrating changes of oxygenated hemoglobin (ΔHbO2) and deoxygenated hemoglobin (ΔHHb). This study aimed to evaluate phase-dependent changes in cerebral oxygenation (rSO₂, ΔO₂Hb, ΔHHb) and optic nerve sheath diameter (ONSD) during RALP, and to assess their temporal correlation. This prospective observational study enrolled forty adult patients (ASA I–III) undergoing RALP in steep Trendelenburg position (30 degrees) at Nuovo Ospedale di Prato, Italy, between November 2024 and May 2025. Cerebral oxygenation was continuously monitored using near-infrared spectroscopy (NIRS). ONSD was measured bilaterally using ultrasound at predefined time points: baseline (T0), 45 min after Trendelenburg positioning (T1), 120 min after Trendelenburg (T2), during vesicourethral anastomosis (T3), and before extubation in neutral position (T4). Pearson correlation coefficients were calculated to assess the association between NIRS-derived parameters and ONSD changes. Compared with baseline, Trendelenburg positioning was associated with significant phase-dependent changes in cerebral oxygenation and hemoglobin-derived parameters. rSO₂ and ΔO₂Hb increased during early and prolonged Trendelenburg phases, peaking during vesicourethral anastomosis (T3), and partially decreased after return to supine position (T4). ΔHHb demonstrated a progressive increase during later intraoperative phases, reaching highest values at T3 and T4. ONSD increased progressively across phases on both sides (right: 3.79 ± 0.36 mm at T0 to 4.59 ± 0.47 mm at T3; left: 3.80 ± 0.42 mm to 4.73 ± 0.47 mm). Correlation analysis demonstrated a moderate-to-strong association between ΔHHb and ONSD (right: r = 0.63, p < 10⁻¹⁶; left: r = 0.63, p < 10⁻¹⁶), supporting temporal coupling between cerebral deoxygenated hemoglobin accumulation and optic nerve sheath expansion. This study demonstrates distinct phase-dependent cerebral oxygenation patterns during RALP. The late-phase increase in ΔHHb occurring alongside ONSD enlargement may reflect cerebral venous congestion, a mechanism potentially involved in cerebral edema development during prolonged steep Trendelenburg positioning.
- Open Access
- 13 January 2026
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (4) , 750-756
Clinical evaluation of a spot-check ECG for the diagnosis of atrial fibrillation
- 13 January 2026
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (4) , 750-756
Open AccessClinical evaluation of a spot-check ECG for the diagnosis of atrial fibrillation
- Open Access
- 11 October 2024
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 139 (6) , e62-e64
Pulse Oximetry Performance in Darkly Pigmented Skin: Methodological Concerns
- 11 October 2024
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 139 (6) , e62-e64
Open AccessPulse Oximetry Performance in Darkly Pigmented Skin: Methodological Concerns
- Open Access
- 30 May 2024
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 110 (1) , 110-111
Response to ‘Randomised crossover study on pulse oximeter readings from different sensors in very preterm infants’ by Maiwaldet al
- 30 May 2024
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 110 (1) , 110-111
Open AccessResponse to ‘Randomised crossover study on pulse oximeter readings from different sensors in very preterm infants’ by Maiwaldet al
- Open Access
- 19 January 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (2) , 347-354
Racial effects on masimo pulse oximetry: impact of low perfusion index
Purpose: Evaluate the SpO2-SaO2 difference between Black and White volunteer subjects having a low perfusion index (Pi) compared to those having a normal Pi. Methods: The Pi data were abstracted from electronic files collected on 7183 paired SpO2-SaO2 samples (3201 Black and 3982 White) from a recently reported desaturation study of 75 subjects (39 Black and 36 White) where SaO2 values were sequentially decreased from 100 to 70%. The Pi values from that dataset were divided into two groups (Pi ≤ 1 or Pi > 1) for analysis. A Pi value ≤ 1 was considered “low perfusion” and a Pi value > 1 was considered “normal perfusion”. Statistical calculations included values of bias (mean difference of SpO2-SaO2), precision (standard deviation of the difference), and accuracy (root-mean-square error [ARMS]). During conditions of low perfusion (Pi ≤ 1, range [0.1 to 1]), overall bias and precision were + 0.48% ± 1.59%, while bias and precision were + 0.19 ± 1.53%, and + 0.91 ± 1.57%, for Black and White subjects, respectively. Results: During normal perfusion (Pi > 1, range [1 to 12]), overall bias and precision were + 0.18% ± 1.34%, while bias and precision were -0.26 ± 1.37%, and − 0.12 ± 1.31%, for Black and White subjects, respectively. ARMS was 1.37% in all subjects with normal perfusion and 1.64% in all subjects with low perfusion. Conclusion: Masimo SET® pulse oximeters with RD SET® sensors are accurate for individuals of both Black and White races when Pi is normal, as well as during conditions when Pi is low. The ARMS for all conditions studied is well within FDA standards. This study was conducted in healthy volunteers during well-controlled laboratory desaturations, and results could vary under certain challenging clinical conditions.
- 19 January 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (2) , 347-354
Open AccessRacial effects on masimo pulse oximetry: impact of low perfusion index
Purpose: Evaluate the SpO2-SaO2 difference between Black and White volunteer subjects having a low perfusion index (Pi) compared to those having a normal Pi. Methods: The Pi data were abstracted from electronic files collected on 7183 paired SpO2-SaO2 samples (3201 Black and 3982 White) from a recently reported desaturation study of 75 subjects (39 Black and 36 White) where SaO2 values were sequentially decreased from 100 to 70%. The Pi values from that dataset were divided into two groups (Pi ≤ 1 or Pi > 1) for analysis. A Pi value ≤ 1 was considered “low perfusion” and a Pi value > 1 was considered “normal perfusion”. Statistical calculations included values of bias (mean difference of SpO2-SaO2), precision (standard deviation of the difference), and accuracy (root-mean-square error [ARMS]). During conditions of low perfusion (Pi ≤ 1, range [0.1 to 1]), overall bias and precision were + 0.48% ± 1.59%, while bias and precision were + 0.19 ± 1.53%, and + 0.91 ± 1.57%, for Black and White subjects, respectively. Results: During normal perfusion (Pi > 1, range [1 to 12]), overall bias and precision were + 0.18% ± 1.34%, while bias and precision were -0.26 ± 1.37%, and − 0.12 ± 1.31%, for Black and White subjects, respectively. ARMS was 1.37% in all subjects with normal perfusion and 1.64% in all subjects with low perfusion. Conclusion: Masimo SET® pulse oximeters with RD SET® sensors are accurate for individuals of both Black and White races when Pi is normal, as well as during conditions when Pi is low. The ARMS for all conditions studied is well within FDA standards. This study was conducted in healthy volunteers during well-controlled laboratory desaturations, and results could vary under certain challenging clinical conditions.
- 13 April 2023
- Published by Elsevier in Pain Management Nursing
- Vol. 24 (2) , 238-239
Prospective Study of Masimo NSS-2 BRIDGE; as a Non-Pharmacological Treatment for Acute Opioid Withdrawal Symptoms
- 13 April 2023
- Published by Elsevier in Pain Management Nursing
- Vol. 24 (2) , 238-239
Prospective Study of Masimo NSS-2 BRIDGE; as a Non-Pharmacological Treatment for Acute Opioid Withdrawal Symptoms
- Open Access
- 12 November 2022
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (2) , 567-574
Racial effects on Masimo pulse oximetry: a laboratory study
Recent publications have suggested that pulse oximeters exhibit reduced accuracy in dark-skinned patients during periods of hypoxemia. Masimo SET® (Signal Extraction Technology®) has been designed, calibrated, and validated using nearly equal numbers of dark and light skinned subjects, with the goal of eliminating differences between pulse oximetry saturation (SpO2) and arterial oxygen saturation (SaO2) values due to skin pigmentation. The accuracy concerns reported in dark-skinned patients led us to perform a retrospective analysis of healthy Black and White volunteers. Seventy-five subjects who self-identified as being racially Black or White underwent a desaturation protocol where SaO2 values were decreased from 100 to 70%, while simultaneous SpO2 values were recorded using Masimo RD SET® sensors. Statistical bias (mean difference) and precision (standard deviation of difference) were − 0.20 ± 1.40% for Black and − 0.05 ± 1.35% for White subjects. Plots of SpO2 versus SaO2 show no significant visible differences between races throughout the saturation range from 70 to 100%. Box plots grouped in 1% saturation bins, from 89–96%, and plotted against concomitant SaO2 values, show that occult hypoxemia (SaO2 < 88% when SpO2 = 92–96%) occurred in only 0.2% of White subject data pairs, but not in any Black subjects. There were no clinically significant differences in bias (mean difference of SpO2-SaO2) found between healthy Black and White subjects. Occult hypoxemia was rare and did not occur in Black subjects. Masimo RD SET® can be used with equal assurance in people with dark or light skin. These laboratory results were obtained in well-controlled experimental conditions in healthy volunteers—not reflecting actual clinical conditions/patients.
- 12 November 2022
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 37 (2) , 567-574
Open AccessRacial effects on Masimo pulse oximetry: a laboratory study
Recent publications have suggested that pulse oximeters exhibit reduced accuracy in dark-skinned patients during periods of hypoxemia. Masimo SET® (Signal Extraction Technology®) has been designed, calibrated, and validated using nearly equal numbers of dark and light skinned subjects, with the goal of eliminating differences between pulse oximetry saturation (SpO2) and arterial oxygen saturation (SaO2) values due to skin pigmentation. The accuracy concerns reported in dark-skinned patients led us to perform a retrospective analysis of healthy Black and White volunteers. Seventy-five subjects who self-identified as being racially Black or White underwent a desaturation protocol where SaO2 values were decreased from 100 to 70%, while simultaneous SpO2 values were recorded using Masimo RD SET® sensors. Statistical bias (mean difference) and precision (standard deviation of difference) were − 0.20 ± 1.40% for Black and − 0.05 ± 1.35% for White subjects. Plots of SpO2 versus SaO2 show no significant visible differences between races throughout the saturation range from 70 to 100%. Box plots grouped in 1% saturation bins, from 89–96%, and plotted against concomitant SaO2 values, show that occult hypoxemia (SaO2 < 88% when SpO2 = 92–96%) occurred in only 0.2% of White subject data pairs, but not in any Black subjects. There were no clinically significant differences in bias (mean difference of SpO2-SaO2) found between healthy Black and White subjects. Occult hypoxemia was rare and did not occur in Black subjects. Masimo RD SET® can be used with equal assurance in people with dark or light skin. These laboratory results were obtained in well-controlled experimental conditions in healthy volunteers—not reflecting actual clinical conditions/patients.
- Open Access
- 26 September 2022
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22 (1) , 1-3
Correspondence to: performance of the new SmartCardia wireless, wearable oximeter: a comparison with arterial SaO2 in healthy volunteers
In a recent publication in BMC Anesthesiology, Rincon, et al.present accuracy data for three pulse oximeters with sensors located at three different anatomic sites. Their results for the Masimo Radical with fingertip sensor are erroneous, and we present valid data here. Rincon, et al.show a Bias ± Precision of 2.02 ± 4.6, while the correct laboratory values are -0.01 ± 1.16. The most probable reason for these invalid data is that insufficient time was used at each saturation plateau to allow stabilization of SpO2 readings on a fingertip sensor. It has been shown in the literature that fingertip sensors require at least a full minute of stable oxygenation conditions before their readings will be the same as earlobe sensors.
- 26 September 2022
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22 (1) , 1-3
Open AccessCorrespondence to: performance of the new SmartCardia wireless, wearable oximeter: a comparison with arterial SaO2 in healthy volunteers
In a recent publication in BMC Anesthesiology, Rincon, et al.present accuracy data for three pulse oximeters with sensors located at three different anatomic sites. Their results for the Masimo Radical with fingertip sensor are erroneous, and we present valid data here. Rincon, et al.show a Bias ± Precision of 2.02 ± 4.6, while the correct laboratory values are -0.01 ± 1.16. The most probable reason for these invalid data is that insufficient time was used at each saturation plateau to allow stabilization of SpO2 readings on a fingertip sensor. It has been shown in the literature that fingertip sensors require at least a full minute of stable oxygenation conditions before their readings will be the same as earlobe sensors.
- 5 July 2022
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 135 (2) , 241-245
Pro-Con Debate: Should Code Sharing Be Mandatory for Publication?
In this Pro-Con commentary article, we discuss whether or not code sharing should be mandatory for scientific publications. Scientific programming is an increasingly prevalent tool in research. However, there are not unified guidelines for code availability requirements. Some journals require code sharing. Others require code descriptions. Yet others have no policies around code sharing. The Pro side presented here argues that code sharing should be mandatory for all scientific publications involving code. This Pro argument comes in 2 parts. First, any defensible reason for not sharing code is an equally valid a reason for the manuscript itself not being published. Second, lack of code sharing requirements creates 2 tiers of science: one where reproducibility is required and one where it is not. Additionally, the Pro authors suggest that a debate over code sharing is itself a decade out-of-date due to the emerging availability of containerization and virtual environment sharing software. The Pro argument concludes with an appeal that authors release code to make their work more understandable by other researchers. The Con side presented here argues that computer source codes of medical technology equipment should not be subject to mandatory public disclosure. The source code is a crucial part of what makes a particular device unique and allows that device to outperform its competition. The Con authors believe that public disclosure of this proprietary information would destroy all incentives for businesses to develop new and improved technologies. Competition in the free marketplace is what drives companies to constantly improve their products, to develop new and better medical devices. The open disclosure of these “trade secret” details would effectively end that competitive drive. Why invest time, money, and energy developing a “better mousetrap” if your competitors can copy it and produce it the next day?
- 5 July 2022
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 135 (2) , 241-245
Pro-Con Debate: Should Code Sharing Be Mandatory for Publication?
In this Pro-Con commentary article, we discuss whether or not code sharing should be mandatory for scientific publications. Scientific programming is an increasingly prevalent tool in research. However, there are not unified guidelines for code availability requirements. Some journals require code sharing. Others require code descriptions. Yet others have no policies around code sharing. The Pro side presented here argues that code sharing should be mandatory for all scientific publications involving code. This Pro argument comes in 2 parts. First, any defensible reason for not sharing code is an equally valid a reason for the manuscript itself not being published. Second, lack of code sharing requirements creates 2 tiers of science: one where reproducibility is required and one where it is not. Additionally, the Pro authors suggest that a debate over code sharing is itself a decade out-of-date due to the emerging availability of containerization and virtual environment sharing software. The Pro argument concludes with an appeal that authors release code to make their work more understandable by other researchers. The Con side presented here argues that computer source codes of medical technology equipment should not be subject to mandatory public disclosure. The source code is a crucial part of what makes a particular device unique and allows that device to outperform its competition. The Con authors believe that public disclosure of this proprietary information would destroy all incentives for businesses to develop new and improved technologies. Competition in the free marketplace is what drives companies to constantly improve their products, to develop new and better medical devices. The open disclosure of these “trade secret” details would effectively end that competitive drive. Why invest time, money, and energy developing a “better mousetrap” if your competitors can copy it and produce it the next day?
- Open Access
- 18 February 2022
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 9 (01) , 015003-12
Consistency of children’s hemodynamic responses during spontaneous speech
Significance: Hemodynamic responses (HRs) are typically averaged across experimental sessions based on the assumption that brain activation is consistent over multiple trials. This may not be a safe assumption, especially in pediatric populations, due to unaccounted effects of inattention, fatigue, or habituation. Aim: The purpose of this study was to quantify the consistency of the HR over speech and language brain regions during speech production in typically developing school-aged children. Approach: Brain activity over speech and language regions of interest (ROIs) was recorded with functional near-infrared spectroscopy during a picture description paradigm with 37 children (aged 7 to 12 years). We divided the 30 experimental trials, each 5 s long, into three segments of 10 trials each corresponding with early (trials 1 to 10), middle (trials 11 to 20), and late (trials 21 to 30) trials. We then compared oxygenated (HbO) and deoxygenated (HbR) hemoglobin concentrations averaged across each 10 trial segment to overall concentrations averaged across all 30 trials. We also compared differential hemoglobin (HbD) across ROIs. Results: HbO and HbR averaged across all experimental trials most strongly correlated with HbO and HbR from early trials. HbD values from channels over most speech and language regions did not appreciably change throughout the experimental session. The exception was HbD values from channels over the dorsal inferior frontal gyrus (dIFG). This region showed significantly higher activation over the left hemisphere during the first segment of the experiment. Conclusions: Our findings suggest that brain activity from speech and language ROIs was relatively consistent over the experimental session. The exception was increased activation of left dIFG during earlier experimental trials. We suggest that researchers critically evaluate the consistency of HRs from different brain regions to determine the reliability of HRs recorded during experimental sessions. This step is instrumental in ensuring that uncontrolled effects do not mask patterns of task-related activation.
- 18 February 2022
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 9 (01) , 015003-12
Open AccessConsistency of children’s hemodynamic responses during spontaneous speech
Significance: Hemodynamic responses (HRs) are typically averaged across experimental sessions based on the assumption that brain activation is consistent over multiple trials. This may not be a safe assumption, especially in pediatric populations, due to unaccounted effects of inattention, fatigue, or habituation. Aim: The purpose of this study was to quantify the consistency of the HR over speech and language brain regions during speech production in typically developing school-aged children. Approach: Brain activity over speech and language regions of interest (ROIs) was recorded with functional near-infrared spectroscopy during a picture description paradigm with 37 children (aged 7 to 12 years). We divided the 30 experimental trials, each 5 s long, into three segments of 10 trials each corresponding with early (trials 1 to 10), middle (trials 11 to 20), and late (trials 21 to 30) trials. We then compared oxygenated (HbO) and deoxygenated (HbR) hemoglobin concentrations averaged across each 10 trial segment to overall concentrations averaged across all 30 trials. We also compared differential hemoglobin (HbD) across ROIs. Results: HbO and HbR averaged across all experimental trials most strongly correlated with HbO and HbR from early trials. HbD values from channels over most speech and language regions did not appreciably change throughout the experimental session. The exception was HbD values from channels over the dorsal inferior frontal gyrus (dIFG). This region showed significantly higher activation over the left hemisphere during the first segment of the experiment. Conclusions: Our findings suggest that brain activity from speech and language ROIs was relatively consistent over the experimental session. The exception was increased activation of left dIFG during earlier experimental trials. We suggest that researchers critically evaluate the consistency of HRs from different brain regions to determine the reliability of HRs recorded during experimental sessions. This step is instrumental in ensuring that uncontrolled effects do not mask patterns of task-related activation.