CommScope (United States)

Type
CompanyLocations
Hickory, United StatesLatest Publications
- Open Access
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 72 (6) , 7517-7529
LensFD: Using Lenses for Improved Sub-6 GHz Massive MIMO Full-Duplex
Massive MIMO has emerged as a key-enabler to deliver the high data-rates in current and next-generation systems. Many massive MIMO deployments use time-division duplex (TDD), thereby opening the door for the potential use of full-duplex at base-stations. In this paper, we present LensFD, a scalable method to enable cost-effective massive MIMO full-duplex operation in sub-6 GHz frequencies with a focus on the CBRS band of 3.5 GHz. LensFD uses a low-cost lens array combined with transmit precoding to reshape the effective beam pattern of antennas in massive MIMO arrays to reduce self-interference. We tested three lens configurations in LensFD experimentally with a software-defined 40-antenna base-station and demonstrate a significant improvement in self-interference reduction and hence overall increased system capacity to 1.6× over the TDD counterpart. As an important contribution, we will open-source the large measurement dataset from our experiments.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 72 (6) , 7517-7529
Open AccessLensFD: Using Lenses for Improved Sub-6 GHz Massive MIMO Full-Duplex
Massive MIMO has emerged as a key-enabler to deliver the high data-rates in current and next-generation systems. Many massive MIMO deployments use time-division duplex (TDD), thereby opening the door for the potential use of full-duplex at base-stations. In this paper, we present LensFD, a scalable method to enable cost-effective massive MIMO full-duplex operation in sub-6 GHz frequencies with a focus on the CBRS band of 3.5 GHz. LensFD uses a low-cost lens array combined with transmit precoding to reshape the effective beam pattern of antennas in massive MIMO arrays to reduce self-interference. We tested three lens configurations in LensFD experimentally with a software-defined 40-antenna base-station and demonstrate a significant improvement in self-interference reduction and hence overall increased system capacity to 1.6× over the TDD counterpart. As an important contribution, we will open-source the large measurement dataset from our experiments.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Modelling and Analysis of FDX cable Systems
Full duplex cable networks are built and analyzed in theoretical models based on the RF performance of their building blocks, including nodes, cables, taps, pluggable devices for taps and cable modems, etc. The key performance-degrading factors in FDX systems are analyzed in the models and the results are proven by experimental results.
- 1 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Modelling and Analysis of FDX cable Systems
Full duplex cable networks are built and analyzed in theoretical models based on the RF performance of their building blocks, including nodes, cables, taps, pluggable devices for taps and cable modems, etc. The key performance-degrading factors in FDX systems are analyzed in the models and the results are proven by experimental results.
- 7 October 2019
- Published by ASME International
Optimal Design and Modeling of Server Cabinets With In-Row Coolers and Air Conditioning Units in a Modular Data Center
In a data center, electronic equipment such as server and switches dissipate heat and the corresponding cooling systems contribute to typically 25–35% of total energy consumption. The heat load continues to increase as there is a greater need for miniaturization and convergence. In 2014, data centers in the U.S. consumed an estimated 70 billion kWh, representing about 1.8% of total U.S. electricity consumption. Based on current trend estimates, U.S. data centers are projected to consume approximately 73 billion kWh in 2020 [1]. Many research and strategies are adopted to minimize energy cost. The recommended dry bulb temperature for long-term operation and reliability for air cooling is between 18–27°C and the largest allowable inlet temperature range to operate at is between 5°C and 45°C with American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) enabling much broader allowable zones) [2]. But understanding a proper cooling system is very important especially for thermal management of IT equipment with high heat loads such as 1U or 2U multi-core, high-end servers and blade servers which provide more computing per watt. Many problems like high inlet temperature due to the mixing of hot air with cold air, local hot spots, lower system reliability, increased failure, and downtime may occur. Among many other approaches to managing high-density racks, in-row coolers are used in between racks to provide cold air and minimize local hot spots. This paper describes a computational study being performed by applying in-row coolers for different rack power configuration with and without aisle containment. The power, as well as the number of racks, are varied to study the effect of raised inlet temperature for the IT equipment in a Computational Fluid Dynamics (CFD) model developed in 6SigmaRoom with the help of built-in library items. A comparative analysis is also performed for a typical small-sized non-raised facility to investigate the efficacy and limitations of in-row coolers in thermal management of IT equipment with variation in rack heat load and containment. Several other aspects like a parametric study of variable opening areas of duct between racks and in-row coolers, the variation of operating flow rate and failure scenarios are also studied to find proper flow distribution, uniformity of outlet temperature and predict better performance, energy savings and reliability. The results are presented for general guidance for flexible and quick installation and safe operation of in-row coolers to improve thermal efficiency.
- 7 October 2019
- Published by ASME International
Optimal Design and Modeling of Server Cabinets With In-Row Coolers and Air Conditioning Units in a Modular Data Center
In a data center, electronic equipment such as server and switches dissipate heat and the corresponding cooling systems contribute to typically 25–35% of total energy consumption. The heat load continues to increase as there is a greater need for miniaturization and convergence. In 2014, data centers in the U.S. consumed an estimated 70 billion kWh, representing about 1.8% of total U.S. electricity consumption. Based on current trend estimates, U.S. data centers are projected to consume approximately 73 billion kWh in 2020 [1]. Many research and strategies are adopted to minimize energy cost. The recommended dry bulb temperature for long-term operation and reliability for air cooling is between 18–27°C and the largest allowable inlet temperature range to operate at is between 5°C and 45°C with American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) enabling much broader allowable zones) [2]. But understanding a proper cooling system is very important especially for thermal management of IT equipment with high heat loads such as 1U or 2U multi-core, high-end servers and blade servers which provide more computing per watt. Many problems like high inlet temperature due to the mixing of hot air with cold air, local hot spots, lower system reliability, increased failure, and downtime may occur. Among many other approaches to managing high-density racks, in-row coolers are used in between racks to provide cold air and minimize local hot spots. This paper describes a computational study being performed by applying in-row coolers for different rack power configuration with and without aisle containment. The power, as well as the number of racks, are varied to study the effect of raised inlet temperature for the IT equipment in a Computational Fluid Dynamics (CFD) model developed in 6SigmaRoom with the help of built-in library items. A comparative analysis is also performed for a typical small-sized non-raised facility to investigate the efficacy and limitations of in-row coolers in thermal management of IT equipment with variation in rack heat load and containment. Several other aspects like a parametric study of variable opening areas of duct between racks and in-row coolers, the variation of operating flow rate and failure scenarios are also studied to find proper flow distribution, uniformity of outlet temperature and predict better performance, energy savings and reliability. The results are presented for general guidance for flexible and quick installation and safe operation of in-row coolers to improve thermal efficiency.
- Open Access
- 29 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (24) , 5841-5848
The Impact of Effective Modal Bandwidth on 100G SWDM Transmission Over 250 m OM5 and Left-Tilt OM4 Multimode Fibers
We demonstrate 100G SWDM4 transmission over 250 m OM5 and left-tilt OM4 multimode fibers. The OM5 fibers are compliant to TIA-492AAAE and the left-tilt OM4 fibers are compliant only to TIA-492AAAD and have a bandwidth peak at a wavelength longer than 850 nm. The “left-tilt” descriptor refers to the leftward leaning slope of the differential mode delay peaks. This is an indication that the peak bandwidth is at a wavelength longer than the measurement wavelength. To measure the margin to the forward error correction limit, 24 250 m channels were constructed from two links of 100 m and 150 m using either left-tilt OM4 or OM5 fiber. Error-free performance was achieved with each of the 24 OM5 channels. None of the 24 left-tilt OM4 channels achieved error-free performance. To further characterize performance, the effective modal bandwidth was measured for 6 left-tilt OM4 fibers and 12 OM5 fibers from the same spools as the fibers used in the margin measurements. The OM4 fibers all have a left tilt at 850 nm and the OM5 fibers have either a left or right tilt. Bit error ratio (BER) versus received power was then measured over 250 m of these fibers. With the OM4 fibers, the long wavelength channels limited the system performance due to low modal bandwidth at longer wavelengths despite the left tilt at 850 nm. We demonstrate the relationship between effective modal bandwidth at 953 nm and BER performance at 910 and 940 nm.
- 29 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (24) , 5841-5848
Open AccessThe Impact of Effective Modal Bandwidth on 100G SWDM Transmission Over 250 m OM5 and Left-Tilt OM4 Multimode Fibers
We demonstrate 100G SWDM4 transmission over 250 m OM5 and left-tilt OM4 multimode fibers. The OM5 fibers are compliant to TIA-492AAAE and the left-tilt OM4 fibers are compliant only to TIA-492AAAD and have a bandwidth peak at a wavelength longer than 850 nm. The “left-tilt” descriptor refers to the leftward leaning slope of the differential mode delay peaks. This is an indication that the peak bandwidth is at a wavelength longer than the measurement wavelength. To measure the margin to the forward error correction limit, 24 250 m channels were constructed from two links of 100 m and 150 m using either left-tilt OM4 or OM5 fiber. Error-free performance was achieved with each of the 24 OM5 channels. None of the 24 left-tilt OM4 channels achieved error-free performance. To further characterize performance, the effective modal bandwidth was measured for 6 left-tilt OM4 fibers and 12 OM5 fibers from the same spools as the fibers used in the margin measurements. The OM4 fibers all have a left tilt at 850 nm and the OM5 fibers have either a left or right tilt. Bit error ratio (BER) versus received power was then measured over 250 m of these fibers. With the OM4 fibers, the long wavelength channels limited the system performance due to low modal bandwidth at longer wavelengths despite the left tilt at 850 nm. We demonstrate the relationship between effective modal bandwidth at 953 nm and BER performance at 910 and 940 nm.
- 1 January 2018
- Published by Optica Publishing Group
- p. M3F.5
100G SWDM Transmission over 250m OM5 and OM4+ Multimode Fibers
We demonstrate 100G SWDM4 transmission over 250m OM5 and OM4+ multimode fibers. Error-free performance was achieved with the OM5 fibers. The OM4+ fibers did not support error-free performance due to low bandwidth at longer wavelengths.
- 1 January 2018
- Published by Optica Publishing Group
- p. M3F.5
100G SWDM Transmission over 250m OM5 and OM4+ Multimode Fibers
We demonstrate 100G SWDM4 transmission over 250m OM5 and OM4+ multimode fibers. Error-free performance was achieved with the OM5 fibers. The OM4+ fibers did not support error-free performance due to low bandwidth at longer wavelengths.
- 1 January 2016
- Published by Optica Publishing Group
- p. M3F.1
Development Trends in Optical Connectivity
This paper surveys various emerging technological advancements in fiber connectivity, which are enabling disruptive evolution in system design. Major topics of innovation include performance, manufacturing, density, deployment, added functionality, and network intelligence.
- 1 January 2016
- Published by Optica Publishing Group
- p. M3F.1
Development Trends in Optical Connectivity
This paper surveys various emerging technological advancements in fiber connectivity, which are enabling disruptive evolution in system design. Major topics of innovation include performance, manufacturing, density, deployment, added functionality, and network intelligence.
- 3 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Vehicular Technology Magazine
- Vol. 10 (3) , 51-59
Metrocell Antennas: The Positive Impact of a Narrow Vertical Beamwidth and Electrical Downtilt
This article discusses the positive impact that metrocell antennas with a narrow vertical beamwidth and electrical downtilt can have on heterogeneous cellular networks. Using a model of random cell placement based on a Poisson distribution, along with an innovative three-dimensional (3-D) building model that quantifies blockage due to shadowing, it is demonstrated that the network spectral efficiency and average user through-put both increase as the vertical beamwidth decreases and downtilt is applied to metrocell transmission. Moreover, the network becomes more energy efficient. Importantly, these additional gains in network performance can be achieved without any cooperation or exchange of information between macrocell base stations (BSs) and metrocells.
- 3 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Vehicular Technology Magazine
- Vol. 10 (3) , 51-59
Metrocell Antennas: The Positive Impact of a Narrow Vertical Beamwidth and Electrical Downtilt
This article discusses the positive impact that metrocell antennas with a narrow vertical beamwidth and electrical downtilt can have on heterogeneous cellular networks. Using a model of random cell placement based on a Poisson distribution, along with an innovative three-dimensional (3-D) building model that quantifies blockage due to shadowing, it is demonstrated that the network spectral efficiency and average user through-put both increase as the vertical beamwidth decreases and downtilt is applied to metrocell transmission. Moreover, the network becomes more energy efficient. Importantly, these additional gains in network performance can be achieved without any cooperation or exchange of information between macrocell base stations (BSs) and metrocells.
- 6 July 2015
- Published by ASME International
Thermal Modeling of Remote Radio Head Units
Thermal modeling of concealed Remote Radio Head (RRH) units which are placed on a cell tower is the main interest of this paper. RRH units which dissipate fixed amount of heat are modeled in higher ambient temperature. The effect of creating an enclosure on the open air assembly of RRH units is studied. The aim of this study is to analyze if concealment of the RRH units is possible under natural convection for cooling under boundary conditions with inlet temperature 55°C, solar loading and wind. Also, the study has been made to investigate if stacking of one, two, or three concealed sections is possible under natural convection cooling process. Various configurations were modeled and analyzed using a computational fluid dynamics (CFD) tool. Different temperature profiles are reported. An enclosure has been created and the operating temperatures of the enclosed model and an open model are compared. After studying the air flow pattern in the model, specific design modifications, like placing baffles on top of each RRH unit, are suggested for proper air flow management thereby facilitating efficient thermal management inside the enclosure. Also, addition of baffles helped in removing the hot spots in the model. Stacking concealed sections poses a challenge since hot exhaust air from a lower section may enter the air inlets of top sections. Thereby, higher surface temperatures on RRH units in the upper sections are observed. Orientation of the upper section has been changed to address this issue. Results show that with proper airflow management and arrangement of sections, it is possible to have three sections one on top of the other.
- 6 July 2015
- Published by ASME International
Thermal Modeling of Remote Radio Head Units
Thermal modeling of concealed Remote Radio Head (RRH) units which are placed on a cell tower is the main interest of this paper. RRH units which dissipate fixed amount of heat are modeled in higher ambient temperature. The effect of creating an enclosure on the open air assembly of RRH units is studied. The aim of this study is to analyze if concealment of the RRH units is possible under natural convection for cooling under boundary conditions with inlet temperature 55°C, solar loading and wind. Also, the study has been made to investigate if stacking of one, two, or three concealed sections is possible under natural convection cooling process. Various configurations were modeled and analyzed using a computational fluid dynamics (CFD) tool. Different temperature profiles are reported. An enclosure has been created and the operating temperatures of the enclosed model and an open model are compared. After studying the air flow pattern in the model, specific design modifications, like placing baffles on top of each RRH unit, are suggested for proper air flow management thereby facilitating efficient thermal management inside the enclosure. Also, addition of baffles helped in removing the hot spots in the model. Stacking concealed sections poses a challenge since hot exhaust air from a lower section may enter the air inlets of top sections. Thereby, higher surface temperatures on RRH units in the upper sections are observed. Orientation of the upper section has been changed to address this issue. Results show that with proper airflow management and arrangement of sections, it is possible to have three sections one on top of the other.
- 6 July 2015
- Published by ASME International
Design of the Next Generation Antenna Mounts
Design of new antenna mount with low effective projected area (EPA) and high load carrying capacity for telecommunication towers is discussed in this paper. The main aim is to reduce the EPA of the mount against the wind pressure direction at the desired elevation from ground by reducing the mount frame structure parts compared to the previous mount designs used in the market. The model in itself has to withstand its dead weight, operator’s weight along with five antenna-radio units. The new model has been designed with a single horizontal frame and four supporting structure for EPA reduction and also the EPA is calculated through Image Processing using MATLAB tool which has not been done previously for mounting structures in the telecommunication field. The preliminary stress and deformation results calculated using ANSYS 15.0 tool and future work that has to be carried out for the design are also discussed in this paper.
- 6 July 2015
- Published by ASME International
Design of the Next Generation Antenna Mounts
Design of new antenna mount with low effective projected area (EPA) and high load carrying capacity for telecommunication towers is discussed in this paper. The main aim is to reduce the EPA of the mount against the wind pressure direction at the desired elevation from ground by reducing the mount frame structure parts compared to the previous mount designs used in the market. The model in itself has to withstand its dead weight, operator’s weight along with five antenna-radio units. The new model has been designed with a single horizontal frame and four supporting structure for EPA reduction and also the EPA is calculated through Image Processing using MATLAB tool which has not been done previously for mounting structures in the telecommunication field. The preliminary stress and deformation results calculated using ANSYS 15.0 tool and future work that has to be carried out for the design are also discussed in this paper.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1095323X,p. 1-11
Collaborative mission planning for UAV cluster to optimize relay distance
Unmanned Aerial Vehicles (UAVs) coordinated path planning and intercommunication for visual exploration of a geographical region has recently become crucial. Multiple UAVs cover larger area than a single UAV and eliminate blind spots. To improve the surveillance, survivability and quality of the communication, we propose two algorithms for the route planning of UAV cluster operated in obstacle rich environment: (i) Multiple Population Genetic Algorithm (MPGA) (ii) Relay Selection Criteria (RSC). The main objective of MPGA is to minimize the total mission time while maintaining an optimal distance for communication between the neighboring nodes. MPGA utilizes evolutionary speciation techniques with a novel Feasible Population Creation Method (FPCM) and enhanced Inter-species Crossover Mechanism (ISCM) to obtain diversified routes in remarkably short time. In obtaining collision-free optimum paths, UAVs are subjected to constraints such as limited communication range, maximum maneuverability and fuel capacity. In addition to the path planning, RSC is developed for selection of UAVs relay nodes that is based on the location of the relay relative to source and destination. It is crucial since the Bit Error Rate (BER) performance of the link significantly depends on the location of the selected relay. In this paper, path planning and relay allocation algorithms are combined to have a seamless high quality monitoring of the region and to provide superior Quality of Service (QoS) for audio-video applications. Also, simulations in different operation zones with a cluster of up to six UAVs are performed to verify the feasibility of the proposed algorithms both in optimality and computation time.
- 1 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1095323X,p. 1-11
Collaborative mission planning for UAV cluster to optimize relay distance
Unmanned Aerial Vehicles (UAVs) coordinated path planning and intercommunication for visual exploration of a geographical region has recently become crucial. Multiple UAVs cover larger area than a single UAV and eliminate blind spots. To improve the surveillance, survivability and quality of the communication, we propose two algorithms for the route planning of UAV cluster operated in obstacle rich environment: (i) Multiple Population Genetic Algorithm (MPGA) (ii) Relay Selection Criteria (RSC). The main objective of MPGA is to minimize the total mission time while maintaining an optimal distance for communication between the neighboring nodes. MPGA utilizes evolutionary speciation techniques with a novel Feasible Population Creation Method (FPCM) and enhanced Inter-species Crossover Mechanism (ISCM) to obtain diversified routes in remarkably short time. In obtaining collision-free optimum paths, UAVs are subjected to constraints such as limited communication range, maximum maneuverability and fuel capacity. In addition to the path planning, RSC is developed for selection of UAVs relay nodes that is based on the location of the relay relative to source and destination. It is crucial since the Bit Error Rate (BER) performance of the link significantly depends on the location of the selected relay. In this paper, path planning and relay allocation algorithms are combined to have a seamless high quality monitoring of the region and to provide superior Quality of Service (QoS) for audio-video applications. Also, simulations in different operation zones with a cluster of up to six UAVs are performed to verify the feasibility of the proposed algorithms both in optimality and computation time.