Hologic (Germany)

Latest Publications
- Open Access
- 17 April 2023
- Published by Wiley in Cancer Cytopathology
- Vol. 131 (7) , 424-432
Comparison of the Hologic Genius Digital Diagnostics System with the ThinPrep Imaging System—A retrospective assessment
Background: Digital cytology (DC) with artificial intelligence (AI) is a new approach. The authors compared DC with liquid‐based cytology (LBC) using computer assistance (CAS) in a retrospective, noninterventional study.Methods: In total, 1994 ThinPrep LBC slides (Hologic), which were previously analyzed in 2020 using an imaging system with CAS in routine cotesting for cytology/human papillomavirus, were reviewed in a blinded mode using the Genius Digital Diagnostics System (Hologic). In 555 cases, a histology result was available. The slides were digitally scanned (volumetric scan) at 14 levels integrated into one. AI algorithms were used to present a gallery of six tiles each (containing objects of interest) in five categories. Six additional tile rows were available, from which the diagnoses were made. All cases with a mismatch between DC and imaging system results were reviewed by an additional cytopathologist.Results: In 86.56% of cases, a complete match between both systems was observed using the same cytology categories. When also considering the histology results, the match was 90.37%. In addition, when a cytology follow‐up and/or a retrospective review was applied, the match reached 97.34%. In only 0.65% of cases was a major discrepancy observed (two grades of cytology or a low‐grade squamous intraepithelial lesion/high‐grade squamous intraepithelial lesion [LSIL/HSIL] shift), and none were identified by DC. Significantly more cases of higher severity (atypical squamous cells cannot exclude high grade [ASC‐H], high‐grade squamous intraepithelial lesion [HSIL]) were identified with DC, and its negative predictive value was higher. The screening time was significantly shorter with DC.Conclusions: With the Genius system for DC, the sensitivity for HSIL+/ASC‐H and the specificity for LSIL and HSIL were superior to LBC and CAS. Screening time was significantly lower.
- 17 April 2023
- Published by Wiley in Cancer Cytopathology
- Vol. 131 (7) , 424-432
Open AccessComparison of the Hologic Genius Digital Diagnostics System with the ThinPrep Imaging System—A retrospective assessment
Background: Digital cytology (DC) with artificial intelligence (AI) is a new approach. The authors compared DC with liquid‐based cytology (LBC) using computer assistance (CAS) in a retrospective, noninterventional study.Methods: In total, 1994 ThinPrep LBC slides (Hologic), which were previously analyzed in 2020 using an imaging system with CAS in routine cotesting for cytology/human papillomavirus, were reviewed in a blinded mode using the Genius Digital Diagnostics System (Hologic). In 555 cases, a histology result was available. The slides were digitally scanned (volumetric scan) at 14 levels integrated into one. AI algorithms were used to present a gallery of six tiles each (containing objects of interest) in five categories. Six additional tile rows were available, from which the diagnoses were made. All cases with a mismatch between DC and imaging system results were reviewed by an additional cytopathologist.Results: In 86.56% of cases, a complete match between both systems was observed using the same cytology categories. When also considering the histology results, the match was 90.37%. In addition, when a cytology follow‐up and/or a retrospective review was applied, the match reached 97.34%. In only 0.65% of cases was a major discrepancy observed (two grades of cytology or a low‐grade squamous intraepithelial lesion/high‐grade squamous intraepithelial lesion [LSIL/HSIL] shift), and none were identified by DC. Significantly more cases of higher severity (atypical squamous cells cannot exclude high grade [ASC‐H], high‐grade squamous intraepithelial lesion [HSIL]) were identified with DC, and its negative predictive value was higher. The screening time was significantly shorter with DC.Conclusions: With the Genius system for DC, the sensitivity for HSIL+/ASC‐H and the specificity for LSIL and HSIL were superior to LBC and CAS. Screening time was significantly lower.
- 29 September 2016
- Published by Springer Nature in Die Dermatologie
- Vol. 67 (12) , 989-995
Local Health Study
- 29 September 2016
- Published by Springer Nature in Die Dermatologie
- Vol. 67 (12) , 989-995
Local Health Study