Acerinox (Spain)

Type
CompanyLocations
Madrid, SpainLatest Publications
- Open Access
- 12 July 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (6) , 7549-7560
Stainless steel reinforcement: New material in the latest draft of second‐generation Eurocode 2
The durability of reinforced concrete structures exposed to aggressive environments is affected by corrosion of carbon steel reinforcement. For this reason, it is of great practical interest to look for alternative solutions guaranteeing durability through the incorporation of corrosion‐resistant materials, such as stainless steel rebars. This type of steel is specially recommended for structures with a long lifespan, located in aggressive environments, with chlorides or de‐icing salts, and for structures where repair, inspection and rehabilitation is complicated. This solution presents a challenge from the point of view of the materials themselves, the mechanical design and their durability. This article presents the material properties of stainless steel and their influence on concrete structures. Furthermore, it is explained how these properties have been taken into account in the latest draft of the second‐generation Eurocode 2.
- 12 July 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (6) , 7549-7560
Open AccessStainless steel reinforcement: New material in the latest draft of second‐generation Eurocode 2
The durability of reinforced concrete structures exposed to aggressive environments is affected by corrosion of carbon steel reinforcement. For this reason, it is of great practical interest to look for alternative solutions guaranteeing durability through the incorporation of corrosion‐resistant materials, such as stainless steel rebars. This type of steel is specially recommended for structures with a long lifespan, located in aggressive environments, with chlorides or de‐icing salts, and for structures where repair, inspection and rehabilitation is complicated. This solution presents a challenge from the point of view of the materials themselves, the mechanical design and their durability. This article presents the material properties of stainless steel and their influence on concrete structures. Furthermore, it is explained how these properties have been taken into account in the latest draft of the second‐generation Eurocode 2.
- 30 April 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1431 (1) , 925-932
Pitting corrosion detection of austenitic stainless steel EN 1.4404 in MgCl2 solutions using a machine learning approach
Different classification techniques such as Classification Tree (CT), Discriminant Analysis (DA), K-Nearest Neighbour (KNN) and Back-Propagation Neural Networks (BPNN) have been used to model pitting corrosion behaviour of austenitic stainless steel EN 1.4404. The main purpose is to predict the corrosion status of this material in different environmental conditions. Samples of this alloy have been subjected to polarization tests in order to determine pitting potentials values (Epit) with different aqueous conditions: chloride concentration (from MgCl2 solutions), pH values and temperature. In this way, the classification methods employed try to simulate the relation between corrosion status and those various environmental parameters studied. These techniques have generally been regarded as successful, giving a good correlation between experimental and predicted data. High values for precision have been obtained for all the models making these techniques an useful tool to know the behaviour of austenitic stainless steel in different environmental conditions.
- 30 April 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1431 (1) , 925-932
Pitting corrosion detection of austenitic stainless steel EN 1.4404 in MgCl2 solutions using a machine learning approach
Different classification techniques such as Classification Tree (CT), Discriminant Analysis (DA), K-Nearest Neighbour (KNN) and Back-Propagation Neural Networks (BPNN) have been used to model pitting corrosion behaviour of austenitic stainless steel EN 1.4404. The main purpose is to predict the corrosion status of this material in different environmental conditions. Samples of this alloy have been subjected to polarization tests in order to determine pitting potentials values (Epit) with different aqueous conditions: chloride concentration (from MgCl2 solutions), pH values and temperature. In this way, the classification methods employed try to simulate the relation between corrosion status and those various environmental parameters studied. These techniques have generally been regarded as successful, giving a good correlation between experimental and predicted data. High values for precision have been obtained for all the models making these techniques an useful tool to know the behaviour of austenitic stainless steel in different environmental conditions.
- 7 March 2012
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 32 (1) , 012018
EPMA and EBSD analysis of the chemical and structural changes in 16 wt% chromium stainless steel during deformation
In this study, four AISI 430 (EN 1.4016) steel samples of different initial composition and annealing treatment were submitted to uni-axial tension deformation. The as-supplied and deformed materials were characterized by electron channelling contrast imaging, electron backscatter diffraction and electron probe microanalysis. The results show a clear correlation between chemical composition, annealing treatment and strain level obtained until fracture.
- 7 March 2012
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 32 (1) , 012018
EPMA and EBSD analysis of the chemical and structural changes in 16 wt% chromium stainless steel during deformation
In this study, four AISI 430 (EN 1.4016) steel samples of different initial composition and annealing treatment were submitted to uni-axial tension deformation. The as-supplied and deformed materials were characterized by electron channelling contrast imaging, electron backscatter diffraction and electron probe microanalysis. The results show a clear correlation between chemical composition, annealing treatment and strain level obtained until fracture.
- 7 March 2012
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 32 (1) , 012014
An inter-laboratory comparison of EPMA analysis of alloy steel at low voltage
We present the results of an inter-laboratory comparison of EPMA analysis at low voltage (5-6 kV) of three monophasic alloy steel samples. The aim of the work was to obtain an estimate of the present situation of low-voltage analysis of steel and identify needs for improvement. EPMA analyses of the samples were conducted by seven participant groups using electron microprobes and scanning electron microscopes of different kind, equipped with wavelength- and/or energy-dispersive X-ray spectrometers, and employing their own methodology of analysis. The results using WDS showed essentially an underestimation of the Cr contents, with relative deviations from the reference values ranging from -0.7 % to -17 %, and an overestimation of Fe and Ni, with relative deviations from the reference composition ranging from -4 % to +30 %, and from +14 % to +42 %, respectively. The relative deviations obtained by using EDS showed larger scatter, ranging from -16 % to +54 % for Cr, -0.4 % to +66 % for Fe and from +13 % to +90 % for Ni. Reasons for the differences observed and the scatter of results are discussed.
- 7 March 2012
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 32 (1) , 012014
An inter-laboratory comparison of EPMA analysis of alloy steel at low voltage
We present the results of an inter-laboratory comparison of EPMA analysis at low voltage (5-6 kV) of three monophasic alloy steel samples. The aim of the work was to obtain an estimate of the present situation of low-voltage analysis of steel and identify needs for improvement. EPMA analyses of the samples were conducted by seven participant groups using electron microprobes and scanning electron microscopes of different kind, equipped with wavelength- and/or energy-dispersive X-ray spectrometers, and employing their own methodology of analysis. The results using WDS showed essentially an underestimation of the Cr contents, with relative deviations from the reference values ranging from -0.7 % to -17 %, and an overestimation of Fe and Ni, with relative deviations from the reference composition ranging from -4 % to +30 %, and from +14 % to +42 %, respectively. The relative deviations obtained by using EDS showed larger scatter, ranging from -16 % to +54 % for Cr, -0.4 % to +66 % for Fe and from +13 % to +90 % for Ni. Reasons for the differences observed and the scatter of results are discussed.
- 1 December 2003
- Published by Walter de Gruyter GmbH in International Journal of Materials Research
- Vol. 94 (12) , 1339-1345
Influence of Cu and Sn addition on the corrosion resistance of AISI 304 stainless steel in acid media
Article Influence of Cu and Sn addition on the corrosion resistance of AISI 304 stainless steel in acid media was published on December 1, 2003 in the journal International Journal of Materials Research (volume 94, issue 12).
- 1 December 2003
- Published by Walter de Gruyter GmbH in International Journal of Materials Research
- Vol. 94 (12) , 1339-1345
Influence of Cu and Sn addition on the corrosion resistance of AISI 304 stainless steel in acid media
Article Influence of Cu and Sn addition on the corrosion resistance of AISI 304 stainless steel in acid media was published on December 1, 2003 in the journal International Journal of Materials Research (volume 94, issue 12).
- 1 January 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 372 (2) , 352-359
Time-resolved laser-induced plasma spectrometry for determination of minor elements in steelmaking process samples
A pulsed Nd:YAG laser operating on the fourth (266 nm) and second (532 nm) harmonics has been used to generate plasmas on the target surface in air at atmospheric pressure. The influence of wavelength on quantitative analysis of 4 minor elements in stainless steel samples (Si, Ti, Nb and Mo) was investigated. Stainless steel samples with different elemental concentrations were prepared and analyzed by laser-induced plasma spectrometry (LIPS). The effect of laser wavelength on analytical figures of merit (calibration curves, correlation coefficients, linear dynamic ranges, analytical precision, and accuracy values) was found to be negligible when internal standardization (an Fe line) and time-resolved laser-induced plasma are employed. For both wavelengths, the calibration curves presented a good linearity and an acceptable linear dynamic range in the concentration interval investigated. For the four elements studied, limits of detection lower than 150 µg g–1 were achieved. To evaluate the influence of wavelength on precision and accuracy, a set of fifteen high-alloyed steel samples from different stages of steelmaking process have been analyzed. Finally, the long-term stability of the analytical measurements for Mo with 532 nm wavelength has been discussed. RSD values were lower than 5.3% for the elements studied.
- 1 January 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 372 (2) , 352-359
Time-resolved laser-induced plasma spectrometry for determination of minor elements in steelmaking process samples
A pulsed Nd:YAG laser operating on the fourth (266 nm) and second (532 nm) harmonics has been used to generate plasmas on the target surface in air at atmospheric pressure. The influence of wavelength on quantitative analysis of 4 minor elements in stainless steel samples (Si, Ti, Nb and Mo) was investigated. Stainless steel samples with different elemental concentrations were prepared and analyzed by laser-induced plasma spectrometry (LIPS). The effect of laser wavelength on analytical figures of merit (calibration curves, correlation coefficients, linear dynamic ranges, analytical precision, and accuracy values) was found to be negligible when internal standardization (an Fe line) and time-resolved laser-induced plasma are employed. For both wavelengths, the calibration curves presented a good linearity and an acceptable linear dynamic range in the concentration interval investigated. For the four elements studied, limits of detection lower than 150 µg g–1 were achieved. To evaluate the influence of wavelength on precision and accuracy, a set of fifteen high-alloyed steel samples from different stages of steelmaking process have been analyzed. Finally, the long-term stability of the analytical measurements for Mo with 532 nm wavelength has been discussed. RSD values were lower than 5.3% for the elements studied.