Type
Facility
Locations
Oldenburg, Germany

Latest Publications

  • Open Access

    Nanoporous Silica Embedded in Nanoporous Platinum: A Versatile Composite Coating for Implant‐Associated Drug Delivery From Neuronal Electrodes

    by Mosaieb Habib, Tim‐Joshua Strauß, Jennifer Harre, Madeleine Goblet, Florian Klodwig‐Kirstein, Jana Schwieger, Michaela Kreienmeyer, Verena Scheper, Athanasia Warnecke, Nina Ehlert, et al.

    Sensorineural hearing loss, resulting from damage to the hair cells of the inner ear, profoundly impairs quality of life. A widely used treatment involves cochlear implants (CIs), which electrically stimulate the remaining spiral ganglion neurons (SGNs) to partially restore auditory function. Despite considerable technological progress, improvements in implant performance are necessary. Local and controlled drug delivery represents a promising strategy to optimize the implant's biological environment and to support the preservation of SGNs. This study introduces a patented implant‐associated local drug delivery system, designed as a nanocomposite coating for electrode contacts. The composite consists of nanoporous silica nanoparticles embedded within nanoporous platinum synthesized via electrochemical deposition combined with templating techniques, resulting in a homogeneous and mechanically robust coating. The porous structure enhances electrochemical performance by increasing the specific surface area, while simultaneously improving drug loading capacity and enabling dexamethasone release. Cytocompatibility tests using fibroblasts and SGNs indicate good cytocompatibility, supporting its suitability for CI applications. Furthermore, reduced TNF‐α levels in stressed dendritic cells following exposure to released dexamethasone suggest a potential anti‐inflammatory effect and provide an initial proof‐of‐concept for the biological functionality. Ultimately, these features suggest that the proposed system may contribute to improved hearing outcomes in CI recipients.

  • Open Access

    Alpha oscillatory activity reveals focused-attentional disparity between cochlear implant users and normal hearing listeners

    by Irina Schierholz, Pascale Sandmann, Andrej Kral

    Cochlear implants (CIs) allow hearing-impaired subjects to regain access to speech. However, the individual outcome variability remains high and unexplained. One contributing factor to the CI performance could be related to higher cognitive functions, which are not as well studied as in normal hearing (NH) populations. To study the cognitive processing in CI-users, in particular attentional processing, we compared the neural correlates of attention of a large cohort of CI-users (n = 37) to those of an age-matched group of NH-listeners (n = 37). The cognitive paradigm used here is a three-stimulus oddball paradigm in both passive and active listening conditions to isolate the attentional difference in unattended and attended task conditions. The addition of a third stimulus-type allowed us to specifically disentangling the attentional processing of task-relevant from the task-irrelevant stimuli. We expanded the previous ERP study by inspecting oscillatory activities. We localized the responsible brain areas and estimated local neural activities in three cortical regions: temporal transverse gyrus dorsolateral prefrontal cortex and inferior parietal lobule. We found alpha activity (8–12 Hz) to be the most relevant correlate of top-down auditory attention. The result on alpha activity suggests that CI-users may have directed their attention toward task-irrelevant stimuli, thereby impeding their focus on task-relevant stimuli. In sum, this study provides important insight into the cognitive attentional processing in CI-users; those may contribute in high listening effort and CI performance variability.

  • Open Access

    Perceptual measures of normal-hearing and hearing-impaired listeners across defined virtual acoustic scenes

    by Merle Gerken, Julia Schütze, Christoph Kirsch, Stephan D. Ewert, Bernhard U. Seeber, Jan Heeren, Tahereh Afghah, Kirsten C. Wagener, Birger Kollmeier, Anna Warzybok

    To achieve a multi-dimensional characterisation of normal-hearing and hearing-impaired listeners' hearing abilities, including standard audiological conditions and virtual acoustic scenes for the evaluation of hearing aids. Within-subjects design, including speech intelligibility and listening effort measurements in two standard conditions and four virtual acoustic scenes, and assessments of loudness scaling, tone-in-noise detection thresholds, and HEAR-COMMAND tool questionnaire. 76 age-matched listeners, including 20 normal-hearing, 25 hearing-impaired without hearing aids, and 31 hearing aid users. Speech intelligibility and hearing aid benefit in virtual acoustic scenes fell between the results of the standard audiological conditions S0N0 and S0N90. The S0N0 and underground station environment were the most challenging conditions regarding speech intelligibility and listening effort. The pure-tone average explained most of the differences between the listener groups in loudness perception and tone-in-noise detection thresholds. Moderate to strong correlations were found between the HEAR-COMMAND tool speech scores and speech intelligibility. The study established a unique measurement database including complex virtual acoustic scenes and demonstrated a connection between speech intelligibility, hearing aid benefit, and other perceptual auditory measures. The database and findings provide a valuable foundation for advancing hearing aid evaluation and can serve as a benchmark in computational audiology.


  • Open Access

    The Relation Between Sustained Listening Under Difficult Conditions and Behavioral, Subjective, and Physiological Indicators of Fatigue

    by Ewald Strasser, Thomas Brand, Jan Rennies

    This study investigated whether sustained listening effort (sLE) contributes to measurable changes in fatigue, defined here as a decline in performance and/or motivation to sustain effort over time and to fatigue-related sleepiness, defined as a physiological state indexed by spontaneous pupil fluctuations. We further evaluated whether the Pupil Unrest Index (PUI) can serve as an objective marker of these processes. Twenty young adults with normal hearing completed a sustained listening task under speech-on-speech masking while simultaneously performing a secondary memory task, tested across four acoustic processing conditions. PUI increased from pre- to posttest in most participants, with the largest rise in the most difficult (unprocessed colocated) condition. Subjective fatigue ratings also increased across sessions, though without systematic differences between conditions. Behavioral results showed sequence effects: performance declined in intermediate conditions, whereas it remained stable in the easiest and hardest conditions, suggesting that both fatigue and motivational regulation shaped outcomes. Together, these findings demonstrate that sLE is associated with increased subjective fatigue and fatigue-related sleepiness. They further support the PUI as a promising objective physiological marker of fatigue-related sleepiness associated with sLE, complementing subjective and behavioral assessments.


  • Open Access

    An open-access dataset of unaided and hearing aid-assisted auditory perception measures in complex virtual acoustic scenes

    by Tahereh Afghah, Jan Heeren, Laura Hartog, Pascal Biermann, Antje Wulff, Anna Warzybok, Kirsten C. Wagener

    This paper presents the design and structure of an open-access audiological dataset created to support hearing aid algorithm development and model-based audiology. It provides comprehensive perceptual measures for individuals with normal hearing and hearing loss, with and without hearing aids. The dataset includes pure-tone audiometry, otoscopy, coupler measurements, the Loudness Validation Method (LVM), tone-in-noise detection, categorical loudness scaling, speech recognition tests (Göttingen Sentence Test, GÖSA; Oldenburg Sentence Test, OLSA), listening effort (Adaptive Categorical Listening Effort Scaling, ACALES), and self-reported hearing and functioning (HEAR-COMMAND Tool). OLSA and ACALES were conducted in both common spatial setups and four virtual acoustic scenes, with aided and unaided conditions for hearing aid users. Data are organised according to the FAIR principles (Findable, Accessible, Interoperable, Reusable). Seventy-six participants. The release includes database documentation, measurement details, raw data, metadata, and structured SQL files. Sample outcomes for individuals with moderate hearing loss are reported here for the OLSA, ACALES, GÖSA, LVM, and audiometry. This dataset enables cross-methodological analysis and provides simulated acoustic scenes for evaluating hearing loss. By combining standardised and novel measures, it offers a baseline resource for model-based audiology research and hearing aid benefit assessment.


  • Open Access

    Standard audiogram classification from loudness scaling data using unsupervised, supervised, and explainable machine learning techniques

    by Chen Xu, Lena Schell-Majoor, Birger Kollmeier

    To address the calibration and procedural challenges inherent in remote audiogram assessment for rehabilitative audiology, this study investigated whether calibration-independent adaptive categorical loudness scaling (ACALOS) data can be used to approximate individual audiograms by classifying listeners into standard Bisgaard audiogram types using machine learning. Three classes of machine learning approaches - unsupervised, supervised, and explainable - were evaluated. Principal component analysis (PCA) was performed to extract the first two principal components, which together explained more than 50 percent of the variance. Seven supervised multi-class classifiers were trained and compared, alongside unsupervised and explainable methods. Model development and evaluation used a large auditory reference database containing ACALOS data (N = 847). The PCA factor map showed substantial overlap between listeners, indicating that cleanly separating participants into six Bisgaard classes based solely on their loudness patterns is challenging. Nevertheless, the models demonstrated reasonable classification performance, with logistic regression achieving the highest accuracy among supervised approaches. These findings demonstrate that machine learning models can predict standard Bisgaard audiogram types, within certain limits, from calibration-independent loudness perception data, supporting potential applications in remote or resource-limited settings without requiring a traditional audiogram.

  • Open Access

    I-DCCRN-VAE: An Improved Deep Representation Learning Framework for Complex VAE-based Single-channel Speech Enhancement

    by Jiatong Li, Simon Doclo

    Recently, a complex variational autoencoder (VAE)-based single-channel speech enhancement system based on the DCCRN architecture has been proposed. In this system, a noise suppression VAE (NSVAE) learns to extract clean speech representations from noisy speech using pretrained clean speech and noise VAEs with skip connections. In this paper, we improve DCCRN-VAE by incorporating three key modifications: 1) removing the skip connections in the pretrained VAEs to encourage more informative speech and noise latent representations; 2) using $\beta$-VAE in pretraining to better balance reconstruction and latent space regularization; and 3) a NSVAE generating both speech and noise latent representations. Experiments show that the proposed system achieves comparable performance as the DCCRN and DCCRN-VAE baselines on the matched DNS3 dataset but outperforms the baselines on mismatched datasets (WSJ0-QUT, Voicebank-DEMEND), demonstrating improved generalization ability. In addition, an ablation study shows that a similar performance can be achieved with classical fine-tuning instead of adversarial training, resulting in a simpler training pipeline.

  • Open Access

    Perceptual Compensation of Ambisonics Recordings for Reproduction in Room

    by Ali Fallah, Shun Nakamura, Steven van de Par

    Ambisonics is a method for capturing and rendering a sound field accurately, assuming that the acoustics of the playback room does not significantly influence the sound field. However, in practice, the acoustics of the playback room may lead to a noticeable degradation in sound quality. We propose a recording and rendering method based on Ambisonics that utilizes a perceptually-motivated approach to compensate for the reverberation of the playback room. The recorded direct and reverberant sound field components in the spherical harmonics (SHs) domain are spectrally and spatially compensated to preserve the relevant auditory cues including the direction of arrival of the direct sound, the spectral energy of the direct and reverberant sound components, and the Interaural Coherence (IC) across each auditory band. In contrast to the conventional Ambisonics, a flexible number of Ambisonics channels can be used for audio rendering. Listening test results show that the proposed method provides a perceptually accurate rendering of the originally recorded sound field, outperforming both conventional Ambisonics without compensation and even ideal Ambisonics rendering in a simulated anechoic room. Additionally, subjective evaluations of listeners seated at the center of the loudspeaker array demonstrate that the method remains robust to head rotation and minor displacements.

  • Open Access

    Calibration offset estimation in mobile hearing tests via categorical loudness scaling

    by Chen Xu, Birger Kollmeier

    Objective: To enable reliable smartphone-based hearing assessments by developing methods to estimate device calibration offsets using categorical loudness scaling (CLS). Design: Calibration offsets were simulated from a Gaussian distribution. Two prediction models - a Bayesian regression model and a nearest neighbor model - were trained on CLS-derived parameters and data from the Oldenburg Hearing Health Repository (OHHR). CLS was chosen because it provides level-independent measures (e.g., dynamic range) that remain robust despite calibration errors. Study Sample: The dataset comprised CLS results from N = 847 participants with a mean age of 70.0 years (SD = 8.7), including 556 male and 291 female listeners with diverse hearing profiles. Results: The Bayesian regression model achieved correlations of up to 0.81 between estimated and true calibration offsets, enabling accurate individual-level correction. Compared to threshold-based approaches, calibration uncertainty was reduced by factors between 0.41 and 0.79, demonstrating greater robustness in uncontrolled environments. Conclusions: CLS-based models can effectively compensate for missing calibration in mobile hearing assessments. This approach provides a practical alternative to threshold-based methods, supporting the use of smartphone-based tests outside laboratory settings and expanding access to reliable hearing healthcare in everyday and resource-limited contexts.