CSChong Shen

Chong Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chong Shen has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Jun-Zu Hu

    4 shared publications
  • Guo-Yao Zou

    Guilin Med Coll, Affiliated Hosp, Dept Orthoped, Guilin, Guangxi, Peoples R China

    3 shared publications
  • Rong-Chi Xiao

    Guilin Med Coll, Affiliated Hosp, Dept Orthoped, Guilin, Guangxi, Peoples R China

    3 shared publications
  • Zhi-Hong Tang

    Guilin Med Coll, Affiliated Hosp, Dept Orthoped, Guilin, Guangxi, Peoples R China

    3 shared publications
  • Dong-Xue Yan

    Guilin Med Coll, Affiliated Hosp, Dept Orthoped, Guilin, Guangxi, Peoples R China

    2 shared publications
  • Li Zheng

    Guangxi Engineering Center in Biomedical Materials for Tissue and Organ Regeneration, The First Affiliated Hospital of Guangxi Medical University, Guangxi Medical University, Nanning, China

    2 shared publications

Latest Publications

  • Open Access

    Engineered Cyanobacteria‐Hydrogel Microecological System for Oxygen Reprogramming Synergizes Immunomodulation With Anabolism in Osteoarthritis Therapy

    by Lerong Yang, Chong Shen, Hongjun Huang, Siyi Liu, Zeyu Huang, Licheng Xi, Huan Cao, Li Zheng, Zainen Qin

    Osteoarthritis remains a major clinical challenge due to its complex pathophysiology involving chronic inflammation and progressive cartilage degradation. Current treatments largely fail to address the dual demands of synovial anti‐inflammation and cartilage anabolism, particularly under the critical yet often overlooked influence of oxygen zonation within articular tissues. In this study, we propose a novel microorganism oxygen metabolism engineering strategy using an injectable cyanobacteria‐laden hydrogel (R‐alga) that enables light‐dependent dynamic oxygen regulation to mimic native physiological oxygen gradients. Under infrared ray (red) light irradiation, cyanobacteria within R‐alga efficiently produce oxygen via photosynthesis, specifically targeting and alleviating hypoxia in the inflamed synovial region. This process significantly suppresses the aberrant expression of HIF‐1α in macrophages, ameliorates their metabolic dysfunction, and effectively scavenges ROS, ultimately inducing macrophage polarization toward an pro‐regenerative phenotype. In the absence of light, cyanobacteria within R‐alga actively consume oxygen through respiration, creating and maintaining a physiologically relevant hypoxic microenvironment in the cartilage defect area. This environment stabilizes HIF‐1α expression in chondrocytes, activates the HIF‐1α‐DOT1L signaling axis, and significantly enhances the biosynthesis of key cartilage matrix components, thereby facilitating cartilage repair. Collectively, the microorganism oxygen metabolismengineering strategy offers a breakthrough for precise control of the osteoarthritis microenvironment and therapy.

  • Open Access

    AI-driven 3D virtual surgical planning in total hip arthroplasty: a machine learning approach for precision implant positioning and improved clinical outcomes

    by Li-Cheng Xi, Bang-Qi Yang, Lin-Hua Jiang, You-Gao Xu, Chong Shen

    To explore the clinical significance of the artificial intelligence (AI)-assisted three-dimensional (3D) planning system AI-HIP in total hip arthroplasty (


  • Endoscopic “cave-in” technique for massive thoracic ossification of the posterior longitudinal ligament combined with thoracic disc herniation with 36 months of follow-up: a case report and review of the literature

    by Junpei Wan, Shihao Deng, Jianfeng Huang, Guoyao Zou, Chong Shen

    Background Both thoracic ossification of the posterior longitudinal ligament (T-OPLL) and thoracic disc herniation (TDH) may cause thoracic spinal stenosis (TSS) resulting in thoracic myelopathy. Surgical decompression is the only effective treatment for symptomatic TSS. 360° Circumferential decompression, also called the “cave-in” technique, can safely and effectively treat T-OPLL; however, this procedure has not yet been performed endoscopically. Herein, we report the first case of massive T-OPLL combined with TDH that was treated endoscopically using the “cave-in” technique, with 36 months of follow-up. Further, we review the literature on this subject. Case Report A 76-year-old woman presented with a 2-year history of progressive numbness and weakness of both lower limbs, and pain and weakness in both lower limbs after sustaining a fall more than 1 month ago, with symptom aggravation since 1 week. Computed tomography (CT) revealed TDH combined with massive T-OPLL at the T6/7 levels. Magnetic resonance imaging (MRI) showed severe compression of the thoracic spinal cord. Two-stage endoscopic circumferential decompression was performed. During a follow-up period of 36 months, the patient recovered with no complications, and CT and MRI confirmed complete decompression of the spinal cord. Conclusion The endoscopic “cave-in” technique can effectively treat T-OPLL with satisfactory clinical results, and is associated with less trauma and fewer complications than conventional posterior circumferential decompression. The endoscopic “cave-in” technique can be a good surgical option for patients with T-OPLL.


  • Open Access

    In vitro culture expansion impairs chondrogenic differentiation and the therapeutic effect of mesenchymal stem cells by regulating the unfolded protein response

    by Chong Shen, Tongmeng Jiang, Bo Zhu, Yiguan Le, Jianwei Liu, Zainen Qin, Haimin Chen, Gang Zhong, Li Zheng, Jinmin Zhao, et al.

    In vitro expansion of mesenchymal stem cells (MSCs) has been implicated in loss of multipotency, leading to impaired chondrogenic potential and an eventual therapeutic effect, as reported in our previous study. However, the precise regulatory mechanism is still unclear. Here, we demonstrate that endoplasmic reticulum (ER) stress and the unfolded protein response (UPR) were involved in transformation of MSCs induced by in vitro culture based on the comparative profiling of in vitro cultured bone marrow MSCs at passage 3 (P3 BMSCs) vs. fresh P0 BMSCs by microarray analysis. Indeed, RT-PCR and Western blot analysis showed significantly lower expression levels of three key UPR-related molecules, ATF4, ATF6 and XBP1, in P3 BMSCs than P0 BMSCs. Further, we found that UPR suppression by 4-phenylbutyrate (4-PBA) reduced the chondrogenic potential of P0 BMSCs and further cartilage regeneration. Conversely, UPR induction by tunicamycin (TM) enhanced the chondrogenic differentiation of P3 BMSCs and the therapeutic effect on cartilage repair. Thus, the decline in the chondrogenic potential of stem cells after in vitro culture and expansion may be due to changes in ER stress and the UPR pathway.


  • Cardiac Perforation and Multiple Emboli After Percutaneous Vertebroplasty

    by Chong Shen, Gang Liu, Jun-Zu Hu, Xi-Heng Yang

    Case Report Free Chong Shen, MD; Gang Liu, MD; Jun-Zu Hu, MD; Xi-Heng Yang, MD Percutaneous vertebroplasty is a minimally invasive technique for treating vertebral compression fractures and tumors. Although percutaneous vertebroplasty is considered a relatively safe and technically simple procedure, it is also associated with life-threatening complications as a result of cement leakage, including cardiac perforation and pulmonary embolism. A 63-year-old woman underwent percutaneous vertebroplasty for an L3 vertebral fracture and had cement leaks into the inferior vena cava, pulmonary arteries, and right heart chambers, with a free wall perforation. Surgical removal of the cement emboli was recommended as a result of apparent penetration of the ventricle and the fragile nature of polymethyl methacrylate. A cardiopulmonary bypass was immediately performed via a right atriotomy. A foreign body 10 cm in length was removed from the right atrium and ventricle. Arteriotomies were then performed, and 4 cement filaments were retrieved from the pulmonary arteries. The inferior vena cava was also surgically opened, allowing extraction of a cement fragment that was 12 cm long. The postoperative course was uneventful, and the patient fully recovered. This is the first report of the migration of a cement fragment larger than 10 cm that had migrated and embedded in the heart chamber. This report showed that imaging analysis is valuable when cement leakage is detected during percutaneous vertebroplasty and can be used to avoid serious complications and improve patient outcomes. [Orthopedics. 2015; 38(10):e947–e950.] In recent years, percutaneous vertebroplasty has become a widely used treatment for vertebral compression fractures and tumors.1 Although this procedure is considered relatively safe and technically simple, it is also associated with life-threatening complications as a result of cement leakage, including cardiac perforation and pulmonary embolism.2,3 The authors report a case of cement embolization after percutaneous vertebroplasty that involved the inferior vena cava, pulmonary arteries, and right heart, with free wall perforation. A 63-year-old woman presented to the authors’ hospital with dyspnea and chest pain. The history showed a previous diagnosis of osteoporosis, but no previous cardiac events or other potentially relevant medical conditions. Two weeks earlier, the patient underwent percutaneous vertebroplasty at another institution with polymethyl methacrylate (PMMA) cement for repair of a compression fracture of L3. One day later, the patient had light dyspnea and chest pain and underwent treatment with oxygen. The patient was considered stable, with complete resolution of the symptoms, and was discharged. However, 12 days after the procedure, she had progressive chest pain and dyspnea and presented to the authors’ hospital for urgent care. Electrocardiogram on admission showed increased sinus tachycardia at 124 beats/min (normal range, 60–100 beats/min). Radiography and computed tomography scans showed multiple hyperdense foreign objects in the inferior vena cava, left main pulmonary artery, right pulmonary artery branch, right atrium, and right ventricle, with a free wall perforation (Figures 1A–C ). Transthoracic echocardiography showed a hyperechoic linear structure that was embedded in the right atrium and right ventricle and was accompanied by moderate pericardial effusion (Figure 1D ). Figure 1: Imaging findings on admission preoperatively. Chest radiograph showing multiple hyperdense foreign objects distributed within the pulmonary arteries and cardiac chamber (arrows) (A). Abdominal radiograph of L3 showing polymethyl methacrylate cement leakage into the perivertebral venous system and inferior vena cava (arrows) (B). Computed tomography scan showing a fishbone-shaped object piercing the right ventricular cavity (arrow) (C). Echocardiogram of the right ventricle showing a hyperechogenic cement fragment (arrow) embedded in the right atrium and ventricle (D). Surgical removal of the foreign body structures was recommended because of apparent penetration of the ventricle and the fragile nature of PMMA. Cardiopulmonary bypass was immediately performed with a right atriotomy. A 10-cm–long foreign body was removed from the right atrium and ventricle. Arteriotomies were then performed, and 4 cement filaments were retrieved from the pulmonary arteries (Figure 2 ). The inferior vena cava was also surgically opened, allowing extraction of a 12-cm–long cement fragment (Figure 3 ). The postoperative course was uneventful, and the patient recovered fully. Figure 2: Intraoperative extraction of the polymethyl methacrylate cement emboli. The polymethyl methacrylate fragment is seen penetrating the acute margin of the right ventricle (arrow) (A). Extraction of a fishbone-shaped polymethyl methacrylate fragment from the right ventricle (B). Removal of the polymethyl methacrylate pieces via pulmonary arteriotomy (C). Figure 3: Postoperative confirmation of removal of the polymethyl methacrylate cement fragment. Polymethyl methacrylate fragments that were extracted from the right ventricle (RV), pulmonary artery (PA), and inferior vena cava (IVC) (A). Chest radiograph confirming that all polymethyl methacrylate fragments were removed (B). Percutaneous and transpedicular injection of PMMA during percutaneous vertebroplasty provides mechanical stability to partially collapsed vertebral bodies. This procedure offers rapid pain relief and fortification for bone structure remodeling.4 Despite these benefits, there is a risk that PMMA will enter the vertebral venous plexus through the iliolumbar or epidural veins and subsequently migrate to the inferior vena cava, right heart chambers, and pulmonary arterial system. Pulmonary cement emboli after vertebroplasty are not uncommon, although incidence rates vary from 1% to 23%.1,5 Most cases are asymptomatic, with fewer than 1% presenting with dyspnea,1 and require only observation without treatment. However, for symptomatic cases or patients with a central embolism, standard treatment guidelines for pulmonary thromboembolism, such as anticoagulation, should be followed.6 For patients with large cement fragments in the inferior vena cava, fragment removal is recommended to prevent further migration to the pulmonary arteries, even if the patient is asymptomatic.7 Endovascular fragment retrieval is suggested for patients with a cement fragment embolus in the pulmonary artery.8 Cardiopulmonary bypass and surgical removal of the emboli are recommended for those with a massive embolism leading to cardiac perforation.2 The current patient had cement embolization into the inferior vena cava and pulmonary arteries as well as cardiac perforation, all of which required surgery. To the current authors’ knowledge, this is the only case report of this type. Furthermore, this is the first report of migration of a cement fragment larger than 10 cm that had migrated and embedded in the heart chamber. Previous reports of similar cement-related cardiac perforation and pulmonary emboli involved smaller fragments (range, 1–9 cm).2,9 To minimize the risk of cement emboli, some authors suggest injection of no more than 4 to 6 mL into the vertebral body and the use of bilateral injections.6,7 Additionally, the cementing material should be highly viscous at the time of injection, and injection pressure should be minimized. The current authors reported a 63-year-old woman who had cardiac perforation and multiple large emboli after percutaneous vertebroplasty. Imaging is therefore advised when cement leakage is detected during the procedure because of the risk of serious complications. Figure 1: Imaging findings on admission preoperatively. Chest radiograph showing multiple hyperdense foreign objects distributed within the pulmonary arteries and cardiac chamber (arrows) (A). Abdominal radiograph of L3 showing polymethyl methacrylate cement leakage into the perivertebral venous system and inferior vena cava (arrows) (B). Computed tomography scan showing a fishbone-shaped object piercing the right ventricular cavity (arrow) (C). Echocardiogram of the right ventricle showing a hyperechogenic cement fragment (arrow) embedded in the right atrium and ventricle (D). Figure 2: Intraoperative extraction of the polymethyl methacrylate cement emboli. The polymethyl methacrylate fragment is seen penetrating the acute margin of the right ventricle (arrow) (A). Extraction of a fishbone-shaped polymethyl methacrylate fragment from the right ventricle (B). Removal of the polymethyl methacrylate pieces via pulmonary arteriotomy (C). Figure 3: Postoperative confirmation of removal of the polymethyl methacrylate cement fragment. Polymethyl methacrylate fragments that were extracted from the right ventricle (RV), pulmonary artery (PA), and inferior vena cava (IVC) (A). Chest radiograph confirming that all polymethyl methacrylate fragments were removed (B). The authors are from the Department of Orthopedics (CS, J-ZH) and the Department of Cardiology (X-HY), The Affiliated Hospital of Guilin Medical College; and the Department of Orthopedics (GL), Guangxi Brain Hospital, Guangxi, China. Drs Shen and Liu contributed equally to this work and should be considered as equal first authors. The authors have no relevant financial relationships to disclose. Correspondence should be addressed to: Jun-Zu Hu, MD, Department of Orthopedics, The Affiliated Hospital of Guilin Medical College, No. 15 Lequn Rd, Guilin 541001, Guangxi, China ( sc821@qq.com). 10.3928/01477447-20151002-93 Percutaneous vertebroplasty is a minimally invasive technique for treating vertebral compression fractures and tumors. Although percutaneous vertebroplasty is considered a relatively safe and technically simple procedure, it is also associated with life-threatening complications as a result of cement leakage, including cardiac perforation and pulmonary embolism. A 63-year-old woman underwent percutaneous vertebroplasty for an L3 vertebral fracture and had cement leaks into the inferior vena cava, pulmonary arteries, and right heart chambers, with a free wall perforation. Surgical removal of the cement emboli was recommended as a result of apparent penetration of the ventricle and the fragile nature of polymethyl methacrylate. A cardiopulmonary bypass was immediately performed via a right atriotomy. A foreign body 10 cm in length was removed from the right atrium and ventricle. Arteriotomies were then performed, and 4 cement filaments were retrieved from the pulmonary arteries. The inferior vena cava was also surgically opened, allowing extraction of a cement fragment that was 12 cm long. The postoperative course was uneventful, and the patient fully recovered. This is the first report of the migration of a cement fragment larger than 10 cm that had migrated and embedded in the heart chamber. This report showed that imaging analysis is valuable when cement leakage is detected during percutaneous vertebroplasty and can be used to avoid serious complications and improve patient outcomes. [Orthopedics. 2015; 38(10):e947–e950.] The authors are from the Department of Orthopedics (CS, J-ZH) and the Department of Cardiology (X-HY), The Affiliated Hospital of Guilin Medical College; and the Department of Orthopedics (GL), Guangxi Brain Hospital, Guangxi, China. Drs Shen and Liu contributed equally to this work and should be considered as equal first authors. The authors have no relevant financial relationships to disclose. Correspondence should be addressed to: Jun-Zu Hu, MD, Department of Orthopedics, The Affiliated Hospital of Guilin Medical College, No. 15 Lequn Rd, Guilin 541001, Guangxi, China ( sc821@qq.com). Percutaneous vertebroplasty is a minimally invasive technique for treating vertebral compression fractures and tumors. Although percutaneous vertebroplasty is considered a relatively safe and technically simple procedure, it is also associated with life-threatening complications as a result of cement leakage, including cardiac perforation and pulmonary embolism. A 63-year-old woman underwent percutaneous vertebroplasty for an L3 vertebral fracture and had cement leaks into the inferior vena cava, pulmonary arteries, and right heart chambers, with a free wall perforation. Surgical removal of the cement emboli was recommended as a result of apparent penetration of the ventricle and the fragile nature of polymethyl methacrylate. A cardiopulmonary bypass was immediately performed via a right atriotomy. A foreign body 10 cm in length was removed from the right atrium and ventricle. Arteriotomies were then performed, and 4 cement filaments were retrieved from the pulmonary arteries. The inferior vena cava was also surgically opened, allowing extraction of a cement fragment that was 12 cm long. The postoperative course was uneventful, and the patient fully recovered. This is the first report of the migration of a cement fragment larger than 10 cm that had migrated and embedded in the heart chamber. This report showed that imaging analysis is valuable when cement leakage is detected during percutaneous vertebroplasty and can be used to avoid serious complications and improve patient outcomes. [Orthopedics. 2015; 38(10):e947–e950.] The authors are from the Department of Orthopedics (CS, J-ZH) and the Department of Cardiology (X-HY), The Affiliated Hospital of Guilin Medical College; and the Department of Orthopedics (GL), Guangxi Brain Hospital, Guangxi, China. Drs Shen and Liu contributed equally to this work and should be considered as equal first authors. The authors have no relevant financial relationships to disclose. Correspondence should be addressed to: Jun-Zu Hu, MD, Department of Orthopedics, The Affiliated Hospital of Guilin Medical College, No. 15 Lequn Rd, Guilin 541001, Guangxi, China ( sc821@qq.com). In recent years, percutaneous vertebroplasty has become a widely used treatment for vertebral compression fractures and tumors.1 Although this procedure is considered relatively safe and technically simple, it is also associated with life-threatening complications as a result of cement leakage, including cardiac perforation and pulmonary embolism.2,3 The authors report a case of cement embolization after percutaneous vertebroplasty that involved the inferior vena cava, pulmonary arteries, and right heart, with free wall perforation. A 63-year-old woman presented to the authors’ hospital with dyspnea and chest pain. The history showed a previous diagnosis of osteoporosis, but no previous cardiac events or other potentially relevant medical conditions. Two weeks earlier, the patient underwent percutaneous vertebroplasty at another institution with polymethyl methacrylate (PMMA) cement for repair of a compression fracture of L3. One day later, the patient had light dyspnea and chest pain and underwent treatment with oxygen. The patient was considered stable, with complete resolution of the symptoms, and was discharged. However, 12 days after the procedure, she had progressive chest pain and dyspnea and presented to the authors’ hospital for urgent care. Electrocardiogram on admission showed increased sinus tachycardia at 124 beats/min (normal range, 60–100 beats/min). Radiography and computed tomography scans showed multiple hyperdense foreign objects in the inferior vena cava, left main pulmonary artery, right pulmonary artery branch, right atrium, and right ventricle, with a free wall perforation (Figures 1A–C ). Transthoracic echocardiography showed a hyperechoic linear structure that was embedded in the right atrium and right ventricle and was accompanied by moderate pericardial effusion (Figure 1D ). Figure 1: Imaging findings on admission preoperatively. Chest radiograph showing multiple hyperdense foreign objects distributed within the pulmonary arteries and cardiac chamber (arrows) (A). Abdominal radiograph of L3 showing polymethyl methacrylate cement leakage into the perivertebral venous system and inferior vena cava (arrows) (B). Computed tomography scan showing a fishbone-shaped object piercing the right ventricular cavity (arrow) (C). Echocardiogram of the right ventricle showing a hyperechogenic cement fragment (arrow) embedded in the right atrium and ventricle (D). Surgical removal of the foreign body structures was recommended because of apparent penetration of the ventricle and the fragile nature of PMMA. Cardiopulmonary bypass was immediately performed with a right atriotomy. A 10-cm–long foreign body was removed from the right atrium and ventricle. Arteriotomies were then performed, and 4 cement filaments were retrieved from the pulmonary arteries (Figure 2 ). The inferior vena cava was also surgically opened, allowing extraction of a 12-cm–long cement fragment (Figure 3 ). The postoperative course was uneventful, and the patient recovered fully. Figure 2: Intraoperative extraction of the polymethyl methacrylate cement emboli. The polymethyl methacrylate fragment is seen penetrating the acute margin of the right ventricle (arrow) (A). Extraction of a fishbone-shaped polymethyl methacrylate fragment from the right ventricle (B). Removal of the polymethyl methacrylate pieces via pulmonary arteriotomy (C). Figure 3: Postoperative confirmation of removal of the polymethyl methacrylate cement fragment. Polymethyl methacrylate fragments that were extracted from the right ventricle (RV), pulmonary artery (PA), and inferior vena cava (IVC) (A). Chest radiograph confirming that all polymethyl methacrylate fragments were removed (B). Percutaneous and transpedicular injection of PMMA during percutaneous vertebroplasty provides mechanical stability to partially collapsed vertebral bodies. This procedure offers rapid pain relief and fortification for bone structure remodeling.4 Despite these benefits, there is a risk that PMMA will enter the vertebral venous plexus through the iliolumbar or epidural veins and subsequently migrate to the inferior vena cava, right heart chambers, and pulmonary arterial system. Pulmonary cement emboli after vertebroplasty are not uncommon, although incidence rates vary from 1% to 23%.1,5 Most cases are asymptomatic, with fewer than 1% presenting with dyspnea,1 and require only observation without treatment. However, for symptomatic cases or patients with a central embolism, standard treatment guidelines for pulmonary thromboembolism, such as anticoagulation, should be followed.6 For patients with large cement fragments in the inferior vena cava, fragment removal is recommended to prevent further migration to the pulmonary arteries, even if the patient is asymptomatic.7 Endovascular fragment retrieval is suggested for patients with a cement fragment embolus in the pulmonary artery.8 Cardiopulmonary bypass and surgical removal of the emboli are recommended for those with a massive embolism leading to cardiac perforation.2 The current patient had cement embolization into the inferior vena cava and pulmonary arteries as well as cardiac perforation, all of which required surgery. To the current authors’ knowledge, this is the only case report of this type. Furthermore, this is the first report of migration of a cement fragment larger than 10 cm that had migrated and embedded in the heart chamber. Previous reports of similar cement-related cardiac perforation and pulmonary emboli involved smaller fragments (range, 1–9 cm).2,9 To minimize the risk of cement emboli, some authors suggest injection of no more than 4 to 6 mL into the vertebral body and the use of bilateral injections.6,7 Additionally, the cementing material should be highly viscous at the time of injection, and injection pressure should be minimized. The current authors reported a 63-year-old woman who had cardiac perforation and multiple large emboli after percutaneous vertebroplasty. Imaging is therefore advised when cement leakage is detected during the procedure because of the risk of serious complications. The authors are from the Department of Orthopedics (CS, J-ZH) and the Department of Cardiology (X-HY), The Affiliated Hospital of Guilin Medical College; and the Department of Orthopedics (GL), Guangxi Brain Hospital, Guangxi, China. Drs Shen and Liu contributed equally to this work and should be considered as equal first authors. The authors have no relevant financial relationships to disclose. Correspondence should be addressed to: Jun-Zu Hu, MD, Department of Orthopedics, The Affiliated Hospital of Guilin Medical College, No. 15 Lequn Rd, Guilin 541001, Guangxi, China ( sc821@qq.com). Figure 1: Imaging findings on admission preoperatively. Chest radiograph showing multiple hyperdense foreign objects distributed within the pulmonary arteries and cardiac chamber (arrows) (A). Abdominal radiograph of L3 showing polymethyl methacrylate cement leakage into the perivertebral venous system and inferior vena cava (arrows) (B). Computed tomography scan showing a fishbone-shaped object piercing the right ventricular cavity (arrow) (C). Echocardiogram of the right ventricle showing a hyperechogenic cement fragment (arrow) embedded in the right atrium and ventricle (D). Figure 2: Intraoperative extraction of the polymethyl methacrylate cement emboli. The polymethyl methacrylate fragment is seen penetrating the acute margin of the right ventricle (arrow) (A). Extraction of a fishbone-shaped polymethyl methacrylate fragment from the right ventricle (B). Removal of the polymethyl methacrylate pieces via pulmonary arteriotomy (C). Figure 3: Postoperative confirmation of removal of the polymethyl methacrylate cement fragment. Polymethyl methacrylate fragments that were extracted from the right ventricle (RV), pulmonary artery (PA), and inferior vena cava (IVC) (A). Chest radiograph confirming that all polymethyl methacrylate fragments were removed (B).


  • Patient-Specific Instrumentation Does Not Improve Accuracy in Total Knee Arthroplasty

    by Chong Shen, Zhi-Hong Tang, Jun-Zu Hu, Guo-Yao Zou, Rong-Chi Xiao, Dong-Xue Yan

    Feature Article Chong Shen, MD; Zhi-Hong Tang, MD; Jun-Zu Hu, MD; Guo-Yao Zou, MD; Rong-Chi Xiao, MD; Dong-Xue Yan, MD Patient-specific instrumentation (PSI) has been introduced as a tool to increase the accuracy of total knee arthroplasty (TKA) compared with conventional instrumentation (CLI). However, previous studies have shown inconsistent results. The authors conducted a meta-analysis to compare the performance of PSI to CLI in TKA. PubMed, EMBASE, and Cochrane Central Register of Controlled Trials electronic databases were systematically searched to identify eligible trials published between 2000 and March 2014. Two reviewers independently assessed methodological quality according to the Cochrane Handbook. Subgroup analyses were performed based on the different study designs (randomized, controlled trial [RCT] vs non-randomized, controlled trial [non-RCT]), preoperative magnetic resonance imaging vs computed tomography, and systems of PSI to explore the source of heterogeneity. Fourteen studies (7 RCTs and 7 non-RCTs) involving 1906 patients were included. There were no statistical differences with respect to the outliers of mechanical axis, coronal femoral component, sagittal femoral component, femoral component rotation, operative time, blood loss, and length of hospital stay between PSI and CLI groups. The number of outliers in coronal tibial components (odds ratio, 2.29; 95% confidence interval, 1.20 to 4.35; P=.01) and sagittal tibial components (odds ratio, 1.67; 95% confidence interval, 1.16 to 2.42; P<.01) was significantly lower in the CLI group than in the PSI group. Based on the numbers available, the use of PSI compared with CLI was not likely to improve the accuracy of component alignment and treatment effects of TKA. Further high-quality RCTs are warranted to confirm the authors’ results. [Orthopedics. 2015; 38(3):e178–e188.] The authors are from the Department of Orthopedics, Affiliated Hospital of Guilin Medical College, Guilin, Guangxi, China. The authors have no relevant financial relationships to disclose. Correspondence should be addressed to: Chong Shen, MD, Department of Orthopedics, Affiliated Hospital of Guilin Medical College, Guilin, Guangxi, China ( sc821@foxmail.com). Total knee arthroplasty (TKA) is generally considered the standard treatment for end-stage osteoarthritis of the knee when nonoperative treatments are no longer helpful. Accurate alignment may correlate with good clinical outcomes,1,2 whereas malalignment may result in early loosening, lower functional scores, abnormal stress, and a higher implant failure rate.3–5 In the major arthroplasty centers, the rate of implant malposition could reach 20% to 40% in patients who undergo TKA with conventional instrumentation (CLI).6–8 To limit implant malpositioning, smart tools such as computer-assisted surgery (CAS) and patient-specific instrumentation (PSI) have been developed. Although CAS has been reported to improve alignment and reduce variation,9 it prolongs operative time and increases cost with a risk of pin-related complications.10,11 One recent alternative has been the development of PSI, which uses anatomical data obtained primarily from preoperative computed tomography (CT) or magnetic resonance imaging (MRI) to create disposable cutting blocks to the patient’s individual anatomy. Patient-specific instrumentation has the potential to improve component accuracy, eliminate the alignment outliers, reduce variation in implant position, and save operative time for TKA instruments. Despite its theoretical advantage, the effectiveness of PSI remains controversial. A few clinical studies reported that PSI resulted in better component alignment accuracy than conventional TKA instrumentation,12–14 whereas others reported that PSI did not surpass the accuracy of the CLI technique.15–18 The inconsistent results may be due to small sample sizes, diverse ethnicities, and different instruments. Several reviews have reported that PSI may achieve a high degree of mechanical alignment compared with CLI.19,20 By using meta-analysis to synthesize the evidence and estimate the effect size, the current authors sought to evaluate the performance of PSI compared with CLI in patients undergoing TKA. The authors hypothesized that PSI may have better performance than CLI in TKA concerning (1) outliers, (2) operative time, (3) blood loss, and (4) length of hospital stay. The electronic databases PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials were searched for articles published between 2000 to March 2014 using the following terms: patient-specific, patient-matched, custom cutting, custom fit, total knee arthroplasty, total knee replacement, TKA, and TKR. Reference lists of the relevant articles were manually searched for additional trials. Moreover, gray literature was searched using Google search engines and the registration centers of clinical trials ( www.chictr.org/cn; www.who.int/ictrp/en; www.clinicaltrials.gov; www.nrr.nhs.uk; www.actr.org.au; www.controlled-trials.com; www.trialscentral.org). No languages or publication statuses were restricted. The following inclusion criteria were used: (1) randomized, controlled trial (RCT) or non-RCT; (2) performed in vivo; (3) adult patients underwent primary TKA; (4) compared PSI with CLI; (5) reported the outliers of at least 1 of the following outcomes: mechanical axis, coronal femoral component (CFC), coronal tibial component (CTC), sagittal femoral component (SFC), sagittal tibial component (STC), and femoral component rotation (FCR); and (6) included at least 40 patients. If multiple studies with overlapping data were identified, the authors included only the published report with the largest sample size. All studies that did not meet these criteria were excluded. Two reviewers (C.S., Z.-H.T.) independently extracted data using a standardized extraction form. Disagreements were resolved by...


  • Incidence of Retear With Double-Row Versus Single-Row Rotator Cuff Repair

    by Chong Shen, Zhi-Hong Tang, Jun-Zu Hu, Guo-Yao Zou, Rong-Chi Xiao

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18–2.49]; P =.005; I 2 =0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26–3.71]; P =.005; I 2 =26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed.


  • Does immobilization after arthroscopic rotator cuff repair increase tendon healing? A systematic review and meta-analysis

    by Chong Shen, Zhi-Hong Tang, Jun-Zu Hu, Guo-Yao Zou, Rong-Chi Xiao, Dong-Xue Yan

    To determine whether immobilization after arthroscopic rotator cuff repair improved tendon healing compared with early passive motion. A systematic electronic literature search was conducted to identify randomized controlled trials (RCTs) comparing early passive motion with immobilization after arthroscopic rotator cuff repair. The primary outcome assessed was tendon healing in the repaired cuff. Secondary outcome measures were range of motion (ROM) and American Shoulder and Elbow Surgeons (ASES) shoulder scale, Simple Shoulder Test (SST), Constant, and visual analog scale (VAS) for pain scores. Pooled analyses were performed using a random effects model to obtain summary estimates of treatment effect with 95 % confidence intervals. Heterogeneity among included studies was quantified. Three RCTs examining 265 patients were included. Meta-analysis revealed no significant difference in tendon healing in the repaired cuff between the early-motion and immobilization groups. A significant difference in external rotation at 6 months postoperatively favored early motion over immobilization, but no significant difference was observed at 1 year postoperatively. In one study, Constant scores were slightly higher in the early-motion group than in the immobilization group. Two studies found no significant difference in ASES, SST, or VAS score between groups. We found no evidence that immobilization after arthroscopic rotator cuff repair was superior to early-motion rehabilitation in terms of tendon healing or clinical outcome. Patients in the early-motion group may recover ROM more rapidly. Level II; systematic review of levels I and II studies.