Yanyan Niu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanyan Niu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Wei Sun
Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials College of Chemistry and Chemical Engineering Hainan Normal University Haikou China
9 shared publications Guangjiu Li
Key Laboratory of Optic‐electric Sensing and Analytical Chemistry for Life Science of Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering Qingdao University of Science and Technology Qingdao China
4 shared publicationsWenju Weng
Key Laboratory of Optic‐electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering Qingdao University of Science and Technology Qingdao P. R. China
3 shared publicationsXiaoyan Li
Key Laboratory of Water Pollution Treatment and Resource Reuse of Hainan Province, College of Chemistry and Chemical Engineering Hainan Normal University Haikou People's Republic of China
3 shared publicationsChengxiang Ruan
Jiangxi Key Laboratory of Surface Engineering Jiangxi Science and Technology Normal University Nanchang China
2 shared publicationsChunxiao Yin
Key Laboratory of Optic‐electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering Qingdao University of Science and Technology Qingdao P. R. China
2 shared publications
Latest Publications
- 27 May 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (23) , 4778-4787
Analysis of melatonin simulated metabolism based on electrochemistry coupled online with high performance liquid chromatography-mass spectrometry
Online electrochemistry coupled with high-performance liquid chromatography-mass spectrometry (EC-HPLC-MS) technology has emerged as a powerful tool for simulating biological metabolism and pollutant degradation research due to its unique complementary advantages. This study focuses on melatonin, an important endogenous neuroendocrine hormone characterized by its indole ring structure, as a model compound to investigate electrochemical metabolic simulation. The metabolic process of melatonin was mimicked through linear sweep or constant-potential electrolysis, with the resulting electrolysis products directly transferred to an MS or HPLC-MS system for real-time separation and detection. Additionally, comparison with metabolites obtained via in vitro cultured liver microsome assays demonstrated substantial similarity in their phase I metabolite profiles. Electrochemically simulated metabolites exhibited markedly enhanced MS ion responses under optimized conditions. In contrast, phase II metabolites derived from electrochemical simulation diverged completely from microsomal metabolites, with both methods producing limited product diversity. The proposed EC-MS and EC-HPLC-MS approaches effectively address key limitations of traditional metabolic studies, including challenges in biological sample acquisition and metabolic process control, thereby offering a robust and reproducible alternative for metabolism research. It provides a promising strategy for further exploration of metabolic mechanisms, which is worthy of further improvement and promotion in pharmaceutical and environmental research.
- 27 May 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (23) , 4778-4787
Analysis of melatonin simulated metabolism based on electrochemistry coupled online with high performance liquid chromatography-mass spectrometry
Online electrochemistry coupled with high-performance liquid chromatography-mass spectrometry (EC-HPLC-MS) technology has emerged as a powerful tool for simulating biological metabolism and pollutant degradation research due to its unique complementary advantages. This study focuses on melatonin, an important endogenous neuroendocrine hormone characterized by its indole ring structure, as a model compound to investigate electrochemical metabolic simulation. The metabolic process of melatonin was mimicked through linear sweep or constant-potential electrolysis, with the resulting electrolysis products directly transferred to an MS or HPLC-MS system for real-time separation and detection. Additionally, comparison with metabolites obtained via in vitro cultured liver microsome assays demonstrated substantial similarity in their phase I metabolite profiles. Electrochemically simulated metabolites exhibited markedly enhanced MS ion responses under optimized conditions. In contrast, phase II metabolites derived from electrochemical simulation diverged completely from microsomal metabolites, with both methods producing limited product diversity. The proposed EC-MS and EC-HPLC-MS approaches effectively address key limitations of traditional metabolic studies, including challenges in biological sample acquisition and metabolic process control, thereby offering a robust and reproducible alternative for metabolism research. It provides a promising strategy for further exploration of metabolic mechanisms, which is worthy of further improvement and promotion in pharmaceutical and environmental research.
- Open Access
- 1 February 2023
- Published by Taylor & Francis in Infection and Drug Resistance
- Vol. ume 16, 809-810
Inhibition and Removal of Mature Mixed-Bacteria Biofilms on Voice Prostheses by Sodium Selenite [Corrigendum]
Corrigendum for the article Inhibition and Removal of Mature Mixed-Bacteria Biofilms on Voice Prostheses by Sodium Selenite
- 1 February 2023
- Published by Taylor & Francis in Infection and Drug Resistance
- Vol. ume 16, 809-810
Open AccessInhibition and Removal of Mature Mixed-Bacteria Biofilms on Voice Prostheses by Sodium Selenite [Corrigendum]
Corrigendum for the article Inhibition and Removal of Mature Mixed-Bacteria Biofilms on Voice Prostheses by Sodium Selenite
- 9 September 2022
- Published by Wiley in Electroanalysis
- Vol. 35 (3)
Portable Electrochemical Sensing of Indole‐3‐acetic Acid Based on Self‐assembled MXene and Multi‐walled Carbon Nanotubes Composite Modified Screen‐printed Electrode
As a typical plant hormone, indole‐3‐acetic acid (IAA) can regulate the biological activities including division, growth and differentiation of plant cells. In this paper, a MXene and multi‐walled carbon nanotubes composite was prepared by self‐assembly procedure, which was modified on screen‐printed electrode (SPE) to construct a wireless portable electrochemical sensor. Electrochemical investigations of IAA were studied by cyclic voltammetry and an irreversible oxidation process could be observed. The excellent electroanalytical method of IAA was realized on the modified SPE with the detection range as 0.05–125.0 μmol/L and the detection limit as 16.7 nmol/L. The sensor was used for IAA content analysis in different part of pea seedlings with satisfactory results.
- 9 September 2022
- Published by Wiley in Electroanalysis
- Vol. 35 (3)
Portable Electrochemical Sensing of Indole‐3‐acetic Acid Based on Self‐assembled MXene and Multi‐walled Carbon Nanotubes Composite Modified Screen‐printed Electrode
As a typical plant hormone, indole‐3‐acetic acid (IAA) can regulate the biological activities including division, growth and differentiation of plant cells. In this paper, a MXene and multi‐walled carbon nanotubes composite was prepared by self‐assembly procedure, which was modified on screen‐printed electrode (SPE) to construct a wireless portable electrochemical sensor. Electrochemical investigations of IAA were studied by cyclic voltammetry and an irreversible oxidation process could be observed. The excellent electroanalytical method of IAA was realized on the modified SPE with the detection range as 0.05–125.0 μmol/L and the detection limit as 16.7 nmol/L. The sensor was used for IAA content analysis in different part of pea seedlings with satisfactory results.
- 1 August 2022
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 18 (7) , 781-789
Electrochemical DNA Biosensor Based on Platinum-gold Bimetal Decorated Graphene Modified Electrode for the Detection of Vibrio parahaemolyticus Specific tlh Gene Sequence
Background: By using bimetal nanocomposite modified electrode, the electrochemical DNA biosensor showed the advantages of high sensitivity, low cost, rapid response and convenient operation, which was applied for disease diagnosis, food safety, and biological monitoring. Objective: A nanocomposite consisting of platinum (Pt)-gold (Au) bimetal and two-dimensional graphene (GR) was synthesized by hydrothermal method, which was modified on the surface of carbon ionic liquid electrode and further used for the immobilization of probe ssDNA related to Vibrio parahaemolyticus tlh gene to construct an electrochemical DNA sensor. Method: Potassium ferricyanide was selected as electrochemical indicator, cyclic voltammetry was used to study the electrochemical behaviours of different modified electrodes and differential pulse voltammetry was employed to test the analytical performance of this biosensor for the detection of target gene sequence. Results: This electrochemical DNA biosensor could detect the Vibrio parahaemolyticus tlh gene sequence as the linear concentration in the range from 1.0×10-13 mol L-1 to 1.0×10-6 mol L-1 with the detection limit as 2.91×10-14 mol L-1 (3σ). Conclusion: This proposed electrochemical DNA biosensor could be used to identify the special gene sequence with good selectivity, low detection limit and wide detection range.
- 1 August 2022
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 18 (7) , 781-789
Electrochemical DNA Biosensor Based on Platinum-gold Bimetal Decorated Graphene Modified Electrode for the Detection of Vibrio parahaemolyticus Specific tlh Gene Sequence
Background: By using bimetal nanocomposite modified electrode, the electrochemical DNA biosensor showed the advantages of high sensitivity, low cost, rapid response and convenient operation, which was applied for disease diagnosis, food safety, and biological monitoring. Objective: A nanocomposite consisting of platinum (Pt)-gold (Au) bimetal and two-dimensional graphene (GR) was synthesized by hydrothermal method, which was modified on the surface of carbon ionic liquid electrode and further used for the immobilization of probe ssDNA related to Vibrio parahaemolyticus tlh gene to construct an electrochemical DNA sensor. Method: Potassium ferricyanide was selected as electrochemical indicator, cyclic voltammetry was used to study the electrochemical behaviours of different modified electrodes and differential pulse voltammetry was employed to test the analytical performance of this biosensor for the detection of target gene sequence. Results: This electrochemical DNA biosensor could detect the Vibrio parahaemolyticus tlh gene sequence as the linear concentration in the range from 1.0×10-13 mol L-1 to 1.0×10-6 mol L-1 with the detection limit as 2.91×10-14 mol L-1 (3σ). Conclusion: This proposed electrochemical DNA biosensor could be used to identify the special gene sequence with good selectivity, low detection limit and wide detection range.
- 17 September 2020
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 68 (1) , 114-120
Electrochemical aptamer sensor for highly sensitive detection of mercury ion with Au/Pt@carbon nanofiber‐modified electrode
In this paper, an electrochemical aptamer sensor was proposed for the highly sensitive detection of mercury ion (Hg2+). Carbon nanofiber (CNF) was prepared by electrospinning and high‐temperature carbonization, which was used for the loading of platinum nanoparticles (PtNPs) by the hydrothermal method. The Pt@CNF nanocomposite was modified on the surface of carbon ionic liquid electrode (CILE) to obtain Pt@CNF/CILE, which was further decorated by gold nanoparticles (AuNPs) through electrodeposition to get Au/Pt@CNF/CILE. Self‐assembling of the thiol‐based aptamer was further realized by the formation of Au‐S bond to get an electrochemical aptamer sensor (Aptamer/Au/Pt@CNF/CILE). Due to the specific binding of aptamer probe to Hg2+ with the formation of T‐Hg2+‐T structure, a highly sensitive quantitative detection of Hg2+ could be achieved by recording the changes of current signal after reacting with Hg2+ within the concentration range from 1.0 × 10−15 mol/L to 1.0 × 10−6 mol/L and the detection limit of 3.33 × 10−16 mol/L (3σ). Real water samples were successfully analyzed by this method.
- 17 September 2020
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 68 (1) , 114-120
Electrochemical aptamer sensor for highly sensitive detection of mercury ion with Au/Pt@carbon nanofiber‐modified electrode
In this paper, an electrochemical aptamer sensor was proposed for the highly sensitive detection of mercury ion (Hg2+). Carbon nanofiber (CNF) was prepared by electrospinning and high‐temperature carbonization, which was used for the loading of platinum nanoparticles (PtNPs) by the hydrothermal method. The Pt@CNF nanocomposite was modified on the surface of carbon ionic liquid electrode (CILE) to obtain Pt@CNF/CILE, which was further decorated by gold nanoparticles (AuNPs) through electrodeposition to get Au/Pt@CNF/CILE. Self‐assembling of the thiol‐based aptamer was further realized by the formation of Au‐S bond to get an electrochemical aptamer sensor (Aptamer/Au/Pt@CNF/CILE). Due to the specific binding of aptamer probe to Hg2+ with the formation of T‐Hg2+‐T structure, a highly sensitive quantitative detection of Hg2+ could be achieved by recording the changes of current signal after reacting with Hg2+ within the concentration range from 1.0 × 10−15 mol/L to 1.0 × 10−6 mol/L and the detection limit of 3.33 × 10−16 mol/L (3σ). Real water samples were successfully analyzed by this method.
- 28 November 2019
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 67 (6) , 1054-1061
Electrochemical performance and electrocatalytic behavior of myoglobin on graphene tube‐modified electrode
- 28 November 2019
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 67 (6) , 1054-1061
Electrochemical performance and electrocatalytic behavior of myoglobin on graphene tube‐modified electrode
- 29 April 2019
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 66 (10) , 1341-1346
Investigation of the direct electrochemistry and electrocatalysis of myoglobin on gold nanorods modified electrode
Direct electrochemistry and electrocatalysis of myoglobin (Mb) on a gold nanorod (AuNR)‐decorated carbon ionic liquid electrode (CILE) were studied in this article. The fabricated Nafion/Mb/AuNRs/CILE was used as an electrochemical biosensor for determining trichloroacetic acid (TCA) and sodium nitrite (NaNO2). AuNRs exhibited high metal conductivity, and acted as the bridge between electrochemical active centers of Mb and the substrate electrode with the electron transfer rate accelerated. Electrochemical performances of Nafion/Mb/AuNRs/CILE were checked in pH 3.0 phosphate buffer solution with the electrochemical parameters calculated. Low detection limits and wide linear ranges were obtained in electrocatalytic investigations of different catalytic substrates including TCA and NaNO2, which exhibited potential applications in actual sample detection.
- 29 April 2019
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 66 (10) , 1341-1346
Investigation of the direct electrochemistry and electrocatalysis of myoglobin on gold nanorods modified electrode
Direct electrochemistry and electrocatalysis of myoglobin (Mb) on a gold nanorod (AuNR)‐decorated carbon ionic liquid electrode (CILE) were studied in this article. The fabricated Nafion/Mb/AuNRs/CILE was used as an electrochemical biosensor for determining trichloroacetic acid (TCA) and sodium nitrite (NaNO2). AuNRs exhibited high metal conductivity, and acted as the bridge between electrochemical active centers of Mb and the substrate electrode with the electron transfer rate accelerated. Electrochemical performances of Nafion/Mb/AuNRs/CILE were checked in pH 3.0 phosphate buffer solution with the electrochemical parameters calculated. Low detection limits and wide linear ranges were obtained in electrocatalytic investigations of different catalytic substrates including TCA and NaNO2, which exhibited potential applications in actual sample detection.
- Open Access
- 5 February 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (8) , 4480-4487
Electrochemical performance of myoglobin based on TiO 2 -doped carbon nanofiber decorated electrode and its applications in biosensing
A new biosensing strategy based on a TiO 2 -doped carbon nanofiber (CNF) composite modified electrode was developed.
- 5 February 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (8) , 4480-4487
Open AccessElectrochemical performance of myoglobin based on TiO 2 -doped carbon nanofiber decorated electrode and its applications in biosensing
A new biosensing strategy based on a TiO 2 -doped carbon nanofiber (CNF) composite modified electrode was developed.
- 25 October 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (44) , 5297-5304
A direct electron transfer biosensor based on a horseradish peroxidase and gold nanotriangle modified electrode and electrocatalysis
Gold nanotriangles (AuNTs) were used as a modifier on the surface of a carbon ionic liquid electrode (CILE), which was applied to realize direct electrochemistry and electrocatalysis of horseradish peroxidase (HRP). The modified electrode exhibited excellent activity for electrocatalytic reduction of trichloroacetic acid (TCA) and sodium nitrite (NaNO2). The presence of AuNTs on the electrode surface can bridge the gaps between the electrochemically active sites of HRP and substrate interfaces with the increase of the loading amount of HRP. TEM results confirmed the typical triangular shape of AuNTs and spectroscopic results revealed that no denaturation occurred in the structure of HRP molecules after they were mixed with AuNTs. The electrochemical behavior of Nafion/HRP/AuNTs/CILE was examined in pH 3.0 phosphate buffer solution with the kinetic effect being investigated. The apparent heterogeneous electron transfer rate constant (ks) and the charge transfer coefficient (α) were found to be 1.01 s−1 and 0.49. Electrocatalysis of TCA and NaNO2 was examined with the detection limits calculated to be 0.33 mmol L−1 and 0.53 mmol L−1, respectively. The proposed method was applied to a medical facial peel solution for TCA detection with satisfactory results.
- 25 October 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (44) , 5297-5304
A direct electron transfer biosensor based on a horseradish peroxidase and gold nanotriangle modified electrode and electrocatalysis
Gold nanotriangles (AuNTs) were used as a modifier on the surface of a carbon ionic liquid electrode (CILE), which was applied to realize direct electrochemistry and electrocatalysis of horseradish peroxidase (HRP). The modified electrode exhibited excellent activity for electrocatalytic reduction of trichloroacetic acid (TCA) and sodium nitrite (NaNO2). The presence of AuNTs on the electrode surface can bridge the gaps between the electrochemically active sites of HRP and substrate interfaces with the increase of the loading amount of HRP. TEM results confirmed the typical triangular shape of AuNTs and spectroscopic results revealed that no denaturation occurred in the structure of HRP molecules after they were mixed with AuNTs. The electrochemical behavior of Nafion/HRP/AuNTs/CILE was examined in pH 3.0 phosphate buffer solution with the kinetic effect being investigated. The apparent heterogeneous electron transfer rate constant (ks) and the charge transfer coefficient (α) were found to be 1.01 s−1 and 0.49. Electrocatalysis of TCA and NaNO2 was examined with the detection limits calculated to be 0.33 mmol L−1 and 0.53 mmol L−1, respectively. The proposed method was applied to a medical facial peel solution for TCA detection with satisfactory results.
- 1 August 2018
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 65 (9) , 1127-1135
Electrochemical behavior of horseradish peroxidase on WS2 nanosheet‐modified electrode and electrocatalytic investigation
In this paper, a WS2 nanosheet was modified on the surface of a carbon ionic liquid electrode (CILE), and horseradish peroxidase (HRP) was further fixed on the electrode with a Nafion film. Direct electrochemistry and bioelectrocatalysis of HRP incorporated on the modified electrode were investigated in detail. On Nafion/HRP/WS2/CILE, a pair of well‐defined quasi‐reversible redox peaks appeared on the cyclic voltammogram, indicating that the presence of the WS2 nanosheet on the electrode surface could provide a specific interface with large surface area for HRP and its direct electron transfer rate was greatly enhanced. The formal potential (E0) obtained was –0.179 V, which was the typical feature of heme Fe(III)/Fe(II) in HRP. The electron transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) of HRP were calculated as 0.44 and 1.01 s–1, respectively. This HRP‐modified electrode showed excellent electrocatalytic activity for the reduction of trichloroacetic acid and NaNO2 with a wide linear range and low detection limit. Real samples were detected by this proposed method, indicating the successful fabrication of a new third‐generation electrochemical enzyme sensor utilizing the WS2 nanosheet.
- 1 August 2018
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 65 (9) , 1127-1135
Electrochemical behavior of horseradish peroxidase on WS2 nanosheet‐modified electrode and electrocatalytic investigation
In this paper, a WS2 nanosheet was modified on the surface of a carbon ionic liquid electrode (CILE), and horseradish peroxidase (HRP) was further fixed on the electrode with a Nafion film. Direct electrochemistry and bioelectrocatalysis of HRP incorporated on the modified electrode were investigated in detail. On Nafion/HRP/WS2/CILE, a pair of well‐defined quasi‐reversible redox peaks appeared on the cyclic voltammogram, indicating that the presence of the WS2 nanosheet on the electrode surface could provide a specific interface with large surface area for HRP and its direct electron transfer rate was greatly enhanced. The formal potential (E0) obtained was –0.179 V, which was the typical feature of heme Fe(III)/Fe(II) in HRP. The electron transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) of HRP were calculated as 0.44 and 1.01 s–1, respectively. This HRP‐modified electrode showed excellent electrocatalytic activity for the reduction of trichloroacetic acid and NaNO2 with a wide linear range and low detection limit. Real samples were detected by this proposed method, indicating the successful fabrication of a new third‐generation electrochemical enzyme sensor utilizing the WS2 nanosheet.