Cindy Z. Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cindy Z. Liu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Lihong Victory Wang
Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
3 shared publications - Yide Zhang
Biomedical Engineering Program, University of Colorado Boulder, Boulder, USA
3 shared publications - Qifa Zhou
Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
2 shared publications - Rui Cao
Case Western Reserve University
2 shared publications - Yilin Luo
Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, USA
2 shared publications - Yushun Zeng
Alfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
2 shared publications
Latest Publications
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 2317-2328
High-Speed Volumetric Dual-Mode Ultrasound and Photoacoustic Tomography With a Single-Element Detector
Acoustic wave detection techniques like ultra-sound (US) and photoacoustic (PA) tomography are widely used in biomedical imaging but often require expensive transducer arrays and complex setups for 3D imaging. To overcome these challenges, recent research has explored using an ergodic relay (ER) with a single-element transducer. This approach improves imaging speed at low cost and reduces complexity. This study presents a dual-mode system that utilizes an ER for single-shot, 3D PA and US imaging with a single-element detector. Each ultrasonic or optical excitation pulse generates a 1D signal, which is then used to reconstruct a 3D image in US or PA mode. While the PA mode provides optical absorption-based contrast, the US mode offers complementary acoustic scattering-based contrast. We demonstrate the system’s capabilities through in vivo imaging of blood vessels and skin structure in human hands. The system is non-invasive, label-free, and ultrafast, enabling 4D imaging with simplified hardware requirements.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 2317-2328
High-Speed Volumetric Dual-Mode Ultrasound and Photoacoustic Tomography With a Single-Element Detector
Acoustic wave detection techniques like ultra-sound (US) and photoacoustic (PA) tomography are widely used in biomedical imaging but often require expensive transducer arrays and complex setups for 3D imaging. To overcome these challenges, recent research has explored using an ergodic relay (ER) with a single-element transducer. This approach improves imaging speed at low cost and reduces complexity. This study presents a dual-mode system that utilizes an ER for single-shot, 3D PA and US imaging with a single-element detector. Each ultrasonic or optical excitation pulse generates a 1D signal, which is then used to reconstruct a 3D image in US or PA mode. While the PA mode provides optical absorption-based contrast, the US mode offers complementary acoustic scattering-based contrast. We demonstrate the system’s capabilities through in vivo imaging of blood vessels and skin structure in human hands. The system is non-invasive, label-free, and ultrafast, enabling 4D imaging with simplified hardware requirements.
- Open Access
- 21 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (47) , eadz1820
Rapid cancer diagnosis using deep learning–powered label-free subcellular-resolution photoacoustic histology
Traditional hematoxylin and eosin staining in formalin-fixed paraffin-embedded sections, while essential for diagnostic pathology, is time-consuming, labor intensive, and prone to artifacts that can obscure critical histological details. Label-free ultraviolet photoacoustic microscopy (UV-PAM) has emerged as a promising alternative, offering fast histology-like images without the need for traditional staining and excessive tissue preparation. However, current UV-PAM systems face challenges in achieving the high spatial resolution required for detailed histological analysis and diagnosis. To address this, we developed a subcellular-resolution UV-PAM (SRUV-PAM) system with a 240-nanometer resolution, enabled by the integration of a high numerical aperture (NA) objective lens (NA = 0.64) and the precise piezo actuators for fine scanning control. This configuration allows visualization of detailed nuclear structures. In addition, we demonstrated virtual staining of SRUV-PAM images via cycle-consistent generative adversarial networks and diagnosis of malignant and benign tumors in liver tissues via densely connected convolutional networks DenseNet-121, achieving an area under the receiver operating characteristic curve of 0.902.
- 21 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (47) , eadz1820
Open AccessRapid cancer diagnosis using deep learning–powered label-free subcellular-resolution photoacoustic histology
Traditional hematoxylin and eosin staining in formalin-fixed paraffin-embedded sections, while essential for diagnostic pathology, is time-consuming, labor intensive, and prone to artifacts that can obscure critical histological details. Label-free ultraviolet photoacoustic microscopy (UV-PAM) has emerged as a promising alternative, offering fast histology-like images without the need for traditional staining and excessive tissue preparation. However, current UV-PAM systems face challenges in achieving the high spatial resolution required for detailed histological analysis and diagnosis. To address this, we developed a subcellular-resolution UV-PAM (SRUV-PAM) system with a 240-nanometer resolution, enabled by the integration of a high numerical aperture (NA) objective lens (NA = 0.64) and the precise piezo actuators for fine scanning control. This configuration allows visualization of detailed nuclear structures. In addition, we demonstrated virtual staining of SRUV-PAM images via cycle-consistent generative adversarial networks and diagnosis of malignant and benign tumors in liver tissues via densely connected convolutional networks DenseNet-121, achieving an area under the receiver operating characteristic curve of 0.902.
- 24 June 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 10 (1) , 1-17
Panoramic photoacoustic computed tomography with learning-based classification enhances breast lesion characterization
Breast cancer diagnosis is crucial due to the high prevalence and mortality rate associated with the disease. However, mammography involves ionizing radiation and has compromised sensitivity in radiographically dense breasts, ultrasonography lacks specificity and has operator-dependent image quality, and magnetic resonance imaging faces high cost and patient exclusion. Photoacoustic computed tomography (PACT) offers a promising solution by combining light and ultrasound for high-resolution imaging that detects tumour-related vasculature changes. Here we introduce a workflow using panoramic PACT for breast lesion characterization, offering detailed visualization of vasculature irrespective of breast density. Analysing PACT features of 78 breasts in 39 patients, we develop learning-based classifiers to distinguish between normal and suspicious tissue, achieving a maximum area under the receiver operating characteristic curve of 0.89, which is comparable with that of conventional imaging standards. We further differentiate malignant and benign lesions using 13 features. Finally, we developed a learning-based model to segment breast lesions. Our study identifies PACT as a non-invasive and sensitive imaging tool for breast lesion evaluation.
- 24 June 2025
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 10 (1) , 1-17
Panoramic photoacoustic computed tomography with learning-based classification enhances breast lesion characterization
Breast cancer diagnosis is crucial due to the high prevalence and mortality rate associated with the disease. However, mammography involves ionizing radiation and has compromised sensitivity in radiographically dense breasts, ultrasonography lacks specificity and has operator-dependent image quality, and magnetic resonance imaging faces high cost and patient exclusion. Photoacoustic computed tomography (PACT) offers a promising solution by combining light and ultrasound for high-resolution imaging that detects tumour-related vasculature changes. Here we introduce a workflow using panoramic PACT for breast lesion characterization, offering detailed visualization of vasculature irrespective of breast density. Analysing PACT features of 78 breasts in 39 patients, we develop learning-based classifiers to distinguish between normal and suspicious tissue, achieving a maximum area under the receiver operating characteristic curve of 0.89, which is comparable with that of conventional imaging standards. We further differentiate malignant and benign lesions using 13 features. Finally, we developed a learning-based model to segment breast lesions. Our study identifies PACT as a non-invasive and sensitive imaging tool for breast lesion evaluation.
- Top Cited Papers
- 27 July 2018
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 361 (6400)
Three-dimensional intact-tissue sequencing of single-cell transcriptional states
Transcriptome mapping in the 3D brain: RNA sequencing samples the entire transcriptome but lacks anatomical information. In situ hybridization, on the other hand, can only profile a small number of transcripts. In situ sequencing technologies address these shortcomings but face a challenge in dense, complex tissue environments. Wang et al. combined an efficient sequencing approach with hydrogel-tissue chemistry to develop a multidisciplinary technology for three-dimensional (3D) intact-tissue RNA sequencing (see the Perspective by Knöpfel). More than 1000 genes were simultaneously mapped in sections of mouse brain at single-cell resolution to define cell types and circuit states and to reveal cell organization principles. Science , this issue p. eaat5691 ; see also p. 328
- 27 July 2018
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 361 (6400)
Top Cited PapersThree-dimensional intact-tissue sequencing of single-cell transcriptional states
Transcriptome mapping in the 3D brain: RNA sequencing samples the entire transcriptome but lacks anatomical information. In situ hybridization, on the other hand, can only profile a small number of transcripts. In situ sequencing technologies address these shortcomings but face a challenge in dense, complex tissue environments. Wang et al. combined an efficient sequencing approach with hydrogel-tissue chemistry to develop a multidisciplinary technology for three-dimensional (3D) intact-tissue RNA sequencing (see the Perspective by Knöpfel). More than 1000 genes were simultaneously mapped in sections of mouse brain at single-cell resolution to define cell types and circuit states and to reveal cell organization principles. Science , this issue p. eaat5691 ; see also p. 328
- 26 February 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 89420O-89420O-10
Automated choroidal segmentation method in human eye with 1050nm optical coherence tomography
- 26 February 2014
- Published by SPIE-Intl Soc Optical Eng
- p. 89420O-89420O-10
Automated choroidal segmentation method in human eye with 1050nm optical coherence tomography