Ravindra Kotian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ravindra Kotian has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Prashanthi Madhyastha
Department of Dental Materials, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal 575001, Karnataka, India
5 shared publications Madhu Keshava Bangera
PhD Research Scholar, Department of Dental Materials, Manipal College of Dental Sciences, Mangalore, Affiliated to Manipal Academy of Higher Education, Manipal, Karnataka, India
3 shared publications- Madhu Keshava Bangera
Vivid Dental Care, Pandeshwar 575001, Mangalore, India
3 shared publications Divya Lakshmanan Mangalath
Yenepoya Research Centre Yenepoya (Deemed to be University) Mangalore Karnataka India
2 shared publicationsJayalakshmi Somasundaram
White Lab – Material Research Centre, Saveetha Dental College Chennai Tamil Nadu India
2 shared publicationsSrikant Natarajan
Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education Manipal Karnataka India
2 shared publications
Latest Publications
- 1 February 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (2) , 310-321
Effects of silver nanoparticle-based antimicrobial formulations on the properties of denture polymer: A systematic review and meta-analysis of in vitro studies
- 1 February 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (2) , 310-321
Effects of silver nanoparticle-based antimicrobial formulations on the properties of denture polymer: A systematic review and meta-analysis of in vitro studies
- Open Access
- 7 July 2022
- Published by Springer Nature in Journal of Bio- and Tribo-Corrosion
- Vol. 8 (3) , 1-14
The Evaluation of Biocompatibility, Elemental Composition and Surface Analysis of Retrieved Infra-zygomatic Screws
The study aimed to assess the alterations in the morphology, elemental composition, and biocompatibility of infra-zygomatic crest (IZC) miniscrews, before and after their insertion in the patient’s oral cavity. The study was conducted on 16 IZC miniscrews (8 as-received and 8 retrieved). Scanning electron microscopy (SEM) was used to evaluate the miniscrew surfaces. Micrographs were obtained at ×50, ×100, and ×500 magnification. The miniscrews were subjected to Energy-dispersive x-ray (EDX) analysis to investigate the elemental composition. It was performed at four zones of each miniscrew- head, neck, body, tip. Corrosion of the miniscrews was analyzed through the potentiodynamic polarization (PDP) test by immersing the stainless steel (SS) miniscrews in an artificial saliva medium (pH 5.8) and then allowing it to obtain a steady-state open-circuit potential (OCP) for 15 min. Gingival fibroblasts were cultured using gingival tissue which was used to check the biocompatibility of the miniscrews by observing their proliferation and viability by MTT colorimetric assay. The SEM analysis showed generalized surface dullness, variable corrosion, craters, and blunting in the retrieved miniscrews. EDX analyses showed the deposition of additional elements: carbon, oxygen, calcium, and nitrogen in the retrieved miniscrews. PDP tests showed a higher corrosion rate in the retrieved miniscrews, but the results were not significant. The MTT assay showed that the cell viability was higher in the as-received group and the results were statistically significant with apvalue of 0.002. It was concluded that the retrieved miniscrews exhibited morphologic surface changes in the form of dullness, blunting of threads and tips, corrosion, craters, and cracks which were not seen in the as-received miniscrews. A higher percentage of adsorbed elements were seen on the retrieved miniscrew surface. The corrosion rate assessed through the PDP test for both groups was comparable. The fibroblast cell viability was significantly reduced in the retrieved miniscrews when compared to as-received miniscrews.
- 7 July 2022
- Published by Springer Nature in Journal of Bio- and Tribo-Corrosion
- Vol. 8 (3) , 1-14
Open AccessThe Evaluation of Biocompatibility, Elemental Composition and Surface Analysis of Retrieved Infra-zygomatic Screws
The study aimed to assess the alterations in the morphology, elemental composition, and biocompatibility of infra-zygomatic crest (IZC) miniscrews, before and after their insertion in the patient’s oral cavity. The study was conducted on 16 IZC miniscrews (8 as-received and 8 retrieved). Scanning electron microscopy (SEM) was used to evaluate the miniscrew surfaces. Micrographs were obtained at ×50, ×100, and ×500 magnification. The miniscrews were subjected to Energy-dispersive x-ray (EDX) analysis to investigate the elemental composition. It was performed at four zones of each miniscrew- head, neck, body, tip. Corrosion of the miniscrews was analyzed through the potentiodynamic polarization (PDP) test by immersing the stainless steel (SS) miniscrews in an artificial saliva medium (pH 5.8) and then allowing it to obtain a steady-state open-circuit potential (OCP) for 15 min. Gingival fibroblasts were cultured using gingival tissue which was used to check the biocompatibility of the miniscrews by observing their proliferation and viability by MTT colorimetric assay. The SEM analysis showed generalized surface dullness, variable corrosion, craters, and blunting in the retrieved miniscrews. EDX analyses showed the deposition of additional elements: carbon, oxygen, calcium, and nitrogen in the retrieved miniscrews. PDP tests showed a higher corrosion rate in the retrieved miniscrews, but the results were not significant. The MTT assay showed that the cell viability was higher in the as-received group and the results were statistically significant with apvalue of 0.002. It was concluded that the retrieved miniscrews exhibited morphologic surface changes in the form of dullness, blunting of threads and tips, corrosion, craters, and cracks which were not seen in the as-received miniscrews. A higher percentage of adsorbed elements were seen on the retrieved miniscrew surface. The corrosion rate assessed through the PDP test for both groups was comparable. The fibroblast cell viability was significantly reduced in the retrieved miniscrews when compared to as-received miniscrews.
- 11 April 2022
- Published by Wiley in Polymer Composites
- Vol. 43 (6) , 3626-3638
Effects of graphene nanoplatelets and montmorillonite nanoclay reinforcement on dental polymethyl methacrylate
The study aimed at developing a cytocompatible dental polymer composite with high mechanical and surface characteristics by reinforcing polymethyl methacrylate resin with graphene nanoplatelets and montmorillonite nanoclay. After ball milling the particles into the polymer samples were prepared via conventional compression molding method. Samples were tested for flexural strength, polishability, fatigue failure, wear, hardness, and cytotoxicity. The fracture mode and surface polish were tested using a field emission scanning electron microscope. Most properties displayed enhancement at the tested fraction weight in relation to the control, while some properties were downgraded. However, the tested polymer composite was cytocompatible at all concentrations. Within study limits, graphene nanoplatelets and montmorillonite nanoclay reinforced polymer brought about a positive effect to a particular degree. Establishing optimal concentration of reinforcement and alternate blending methods may boost the resultant characteristics of the resin composite.
- 11 April 2022
- Published by Wiley in Polymer Composites
- Vol. 43 (6) , 3626-3638
Effects of graphene nanoplatelets and montmorillonite nanoclay reinforcement on dental polymethyl methacrylate
The study aimed at developing a cytocompatible dental polymer composite with high mechanical and surface characteristics by reinforcing polymethyl methacrylate resin with graphene nanoplatelets and montmorillonite nanoclay. After ball milling the particles into the polymer samples were prepared via conventional compression molding method. Samples were tested for flexural strength, polishability, fatigue failure, wear, hardness, and cytotoxicity. The fracture mode and surface polish were tested using a field emission scanning electron microscope. Most properties displayed enhancement at the tested fraction weight in relation to the control, while some properties were downgraded. However, the tested polymer composite was cytocompatible at all concentrations. Within study limits, graphene nanoplatelets and montmorillonite nanoclay reinforced polymer brought about a positive effect to a particular degree. Establishing optimal concentration of reinforcement and alternate blending methods may boost the resultant characteristics of the resin composite.
- 25 November 2021
- Published by Wiley in Polymer Composites
- Vol. 43 (2) , 741-752
Behavior of nanosilver and nanotitanium reinforced polymethyl methacrylate for dental applications
The study evaluated the mechanical, tribological, and cytocompatibility properties of silver nanoparticles and titanium dioxide nanoparticles reinforced into polymethyl methacrylate resin. Both nanoparticles were separately ball‐milled with polymethyl methacrylate, and a conventional compression molding technique prepared samples in a thermostatically controlled water bath. Samples were analyzed for flexural strength, polishability, three‐body abrasive wear, surface hardness, and cytotoxicity. The fracture mechanics and surface roughness were further analyzed using a field emission scanning electron microscope. Most properties showed improvement at the said concentration compared to the control group, while few did not show property enhancement. The cell proliferation and viability were not compromised. Within study limits, silver nanoparticles and titanium dioxide nanoparticles reinforced polymethyl methacrylate resin positively influenced the dental polymer to a certain extent. The nanocomposite is cytocompatible at the tested concentrations. Pre‐reaction of the polymer, treating nanoparticles with coupling agents, determining an optimal additive size and concentration, and use of effective dispersion technique may further enhance the properties of the nanocomposites.
- 25 November 2021
- Published by Wiley in Polymer Composites
- Vol. 43 (2) , 741-752
Behavior of nanosilver and nanotitanium reinforced polymethyl methacrylate for dental applications
The study evaluated the mechanical, tribological, and cytocompatibility properties of silver nanoparticles and titanium dioxide nanoparticles reinforced into polymethyl methacrylate resin. Both nanoparticles were separately ball‐milled with polymethyl methacrylate, and a conventional compression molding technique prepared samples in a thermostatically controlled water bath. Samples were analyzed for flexural strength, polishability, three‐body abrasive wear, surface hardness, and cytotoxicity. The fracture mechanics and surface roughness were further analyzed using a field emission scanning electron microscope. Most properties showed improvement at the said concentration compared to the control group, while few did not show property enhancement. The cell proliferation and viability were not compromised. Within study limits, silver nanoparticles and titanium dioxide nanoparticles reinforced polymethyl methacrylate resin positively influenced the dental polymer to a certain extent. The nanocomposite is cytocompatible at the tested concentrations. Pre‐reaction of the polymer, treating nanoparticles with coupling agents, determining an optimal additive size and concentration, and use of effective dispersion technique may further enhance the properties of the nanocomposites.
- 30 November 2020
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 118 (1) , 103
Effect of plasma gas atmosphere on hydroxyapatite-coated titanium-based implants
The study was designed to understand the influence of different atmospheres of plasma gas on hydroxyapatite-coated commercially pure Titanium (Ti) and titanium alloy (Ti-6Al-4V). Ti and Ti-6Al-4V were plasma spray-coated with hydroxyapatite in argon, nitrogen, argon/hydrogen, and nitrogen/hydrogen atmospheres. The microstructure, porosity, calcium to phosphate (Ca-P) ratio, surface roughness, and hardness of the coat were characterized using a scanning electron microscope, energy dispersive spectroscopy, image analyzer, profilometer, and Vickers hardness tester. The analyses of the coatings obtained in different plasma gas atmospheres showed variation in microstructure, morphology, porosity, surface roughness, and hardness. As the enthalpy decreased, an increase in porosity was observed in nitrogen/hydrogen, nitrogen, argon/hydrogen, and argon atmospheres, respectively. Peak Ca-P ratio was observed in argon, which is the most inert atmosphere compared to other tested plasma atmospheres. Atmospheres with high enthalpy presented an even surface with comparatively low surface roughness. Hardness value decreased with increasing porosity. The plasma gas atmosphere has a significant influence on Ca-P ratio, porosity, and microcracks of hydroxyapatite-coated oral implants.
- 30 November 2020
- Published by EDP Sciences in Metallurgical Research & Technology
- Vol. 118 (1) , 103
Effect of plasma gas atmosphere on hydroxyapatite-coated titanium-based implants
The study was designed to understand the influence of different atmospheres of plasma gas on hydroxyapatite-coated commercially pure Titanium (Ti) and titanium alloy (Ti-6Al-4V). Ti and Ti-6Al-4V were plasma spray-coated with hydroxyapatite in argon, nitrogen, argon/hydrogen, and nitrogen/hydrogen atmospheres. The microstructure, porosity, calcium to phosphate (Ca-P) ratio, surface roughness, and hardness of the coat were characterized using a scanning electron microscope, energy dispersive spectroscopy, image analyzer, profilometer, and Vickers hardness tester. The analyses of the coatings obtained in different plasma gas atmospheres showed variation in microstructure, morphology, porosity, surface roughness, and hardness. As the enthalpy decreased, an increase in porosity was observed in nitrogen/hydrogen, nitrogen, argon/hydrogen, and argon atmospheres, respectively. Peak Ca-P ratio was observed in argon, which is the most inert atmosphere compared to other tested plasma atmospheres. Atmospheres with high enthalpy presented an even surface with comparatively low surface roughness. Hardness value decreased with increasing porosity. The plasma gas atmosphere has a significant influence on Ca-P ratio, porosity, and microcracks of hydroxyapatite-coated oral implants.
- Open Access
- 1 November 2020
- Published by Elsevier in Japanese Dental Science Review
- Vol. 56 (1) , 68-76
Effect of titanium dioxide nanoparticle reinforcement on flexural strength of denture base resin: A systematic review and meta-analysis
- 1 November 2020
- Published by Elsevier in Japanese Dental Science Review
- Vol. 56 (1) , 68-76
Open AccessEffect of titanium dioxide nanoparticle reinforcement on flexural strength of denture base resin: A systematic review and meta-analysis
- Open Access
- 1 September 2019
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 8 (5) , 4699-4704
Effect of simulated heating of plasma coating and ceramic firing on Ti and Ti-6Al-4V
- 1 September 2019
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 8 (5) , 4699-4704
Open AccessEffect of simulated heating of plasma coating and ceramic firing on Ti and Ti-6Al-4V
- Open Access
- 1 October 2017
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 11 (04) , 438-446
X-ray diffraction analysis of hydroxyapatite-coated in different plasma gas atmosphere on Ti and Ti-6Al-4V
Objective: The aim is to study the effect of plasma working gas on composition, crystallinity, and microstructure of hydroxyapatite (HA) coated on Ti and Ti-6Al-4V metal substrates. Materials and Methods: Ti and Ti-6Al-4V metal substrates were coated with HA by plasma spray using four plasma gas atmospheres of argon, argon/hydrogen, nitrogen, and nitrogen/hydrogen. The degree of crystallinity, the phases present, and microstructure of HA coating were characterized using X-ray diffraction and scanning electron microscopy. Results: Variation in crystallinity and the microstructure of HA coating on plasma gas atmosphere was observed. Micro-cracks due to thermal stresses and shift in the 2θ angle of HA compared to feedstock was seen. Conclusion: Plasma gas atmosphere has a significant influence on composition, crystallinity, and micro-cracks of HA-coated dental implants.
- 1 October 2017
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 11 (04) , 438-446
Open AccessX-ray diffraction analysis of hydroxyapatite-coated in different plasma gas atmosphere on Ti and Ti-6Al-4V
Objective: The aim is to study the effect of plasma working gas on composition, crystallinity, and microstructure of hydroxyapatite (HA) coated on Ti and Ti-6Al-4V metal substrates. Materials and Methods: Ti and Ti-6Al-4V metal substrates were coated with HA by plasma spray using four plasma gas atmospheres of argon, argon/hydrogen, nitrogen, and nitrogen/hydrogen. The degree of crystallinity, the phases present, and microstructure of HA coating were characterized using X-ray diffraction and scanning electron microscopy. Results: Variation in crystallinity and the microstructure of HA coating on plasma gas atmosphere was observed. Micro-cracks due to thermal stresses and shift in the 2θ angle of HA compared to feedstock was seen. Conclusion: Plasma gas atmosphere has a significant influence on composition, crystallinity, and micro-cracks of HA-coated dental implants.
- Open Access
- 1 January 2017
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 17 (1) , 35-40
In vitro evaluation of cytotoxicity and corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy for dental implants
L-4V (Ti 31). Materials and Methods: In the present in vitro study, cytotoxicity of Ti 12 and Ti 31 in human gingival fibroblast by MTT assay and the corrosion behavior by potentiodynamic polarization technique in aqueous solutions of 0.1 N NaCl, 0.1 N KCl, and artificial saliva with and without NaF were studied. Results: The independent t-test within materials and paired t-test with time interval showed higher cell viability for Ti 12 compared to Ti 31. Over a period, cell viability found to stabilize in both Ti 12 and Ti 31. The effects of ions of Ti and alloying elements aluminum and vanadium on the cell viability were found with incubation period of cells on samples to 72 h. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO2 and additional metal oxides. The multiphase alloy Ti-6Al-4V showed more surface pitting. Conclusion: The commercially pure Ti showed better cell viability compared to Ti 31. Less cell viability in Ti 31 is because of the presence of aluminum and vanadium. A significant decrease in cytotoxicity due to the formation of TiO2 over a period of time was observed both in Ti 12 and Ti 31. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO2 and additional metal oxides. Ti 31 alloy showed surface pitting because of its multiphase structure....
- 1 January 2017
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 17 (1) , 35-40
Open AccessIn vitro evaluation of cytotoxicity and corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy for dental implants
L-4V (Ti 31). Materials and Methods: In the present in vitro study, cytotoxicity of Ti 12 and Ti 31 in human gingival fibroblast by MTT assay and the corrosion behavior by potentiodynamic polarization technique in aqueous solutions of 0.1 N NaCl, 0.1 N KCl, and artificial saliva with and without NaF were studied. Results: The independent t-test within materials and paired t-test with time interval showed higher cell viability for Ti 12 compared to Ti 31. Over a period, cell viability found to stabilize in both Ti 12 and Ti 31. The effects of ions of Ti and alloying elements aluminum and vanadium on the cell viability were found with incubation period of cells on samples to 72 h. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO2 and additional metal oxides. The multiphase alloy Ti-6Al-4V showed more surface pitting. Conclusion: The commercially pure Ti showed better cell viability compared to Ti 31. Less cell viability in Ti 31 is because of the presence of aluminum and vanadium. A significant decrease in cytotoxicity due to the formation of TiO2 over a period of time was observed both in Ti 12 and Ti 31. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO2 and additional metal oxides. Ti 31 alloy showed surface pitting because of its multiphase structure....