DDDarren S. Drosdowech

Darren S. Drosdowech

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Darren S. Drosdowech has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Surgical Technique for Single and Double-Incision Method of Acute Distal Biceps Tendon Repair

    by Ruby Grewal, George S. Athwal, Joy C. MacDermid, Kenneth J. Faber, Darren S. Drosdowech, Graham J.W. King

    Distal biceps tendon ruptures can be repaired with either a single or a double-incision technique. Through a single anterior incision, identify the tendon and debride the distal degenerated portion. Expose the bicipital tuberosity and prepare the bone for insertion of suture anchors. Suture the tendon with a reduction knot technique that allows for anatomic tendon apposition to bone. Through a small anterior incision retrieve the tendon, debride the distal degenerated portion of the tendon, and place your sutures. Through a second posterolateral incision, expose the biceps tuberosity and, using a burr, create a trough for the tendon. Pass the sutures through the transosseous tunnels and tension the sutures, allowing the biceps tendon to be pulled into the trough created in the bicipital tuberosity, and then tie the sutures. Assess tension across the repaired tendon, initiate prophylaxis against heterotopic ossification, and begin rehabilitation. We recently conducted a prospective randomized controlled trial at our center comparing the single and double-incision techniques for the repair of acute distal biceps tendon ruptures11. IndicationsContraindicationsPitfalls & Challenges.


  • Single Versus Double-Incision Technique for the Repair of Acute Distal Biceps Tendon Ruptures

    by Ruby Grewal, George S. Athwal, Joy C. MacDermid, Kenneth J. Faber, Darren S. Drosdowech, Ron El-Hawary, Graham J.W. King

    Background: This clinical trial was done to evaluate outcomes of the single and double-incision techniques for acute distal biceps tendon repair. We hypothesized that there would be fewer complications and less short-term pain and disability in the two-incision group, with no measureable differences in outcome at a minimum of one year postoperatively. Methods: Patients with an acute distal biceps rupture were randomized to either a single-incision repair with use of two suture anchors (n = 47) or a double-incision repair with use of transosseous drill holes (n = 44). Patients were followed at three, six, twelve, and twenty-four months postoperatively. The primary outcome was the American Shoulder and Elbow Surgeons (ASES) elbow score. Secondary outcomes included muscle strength, complication rates, and Disabilities of the Arm, Shoulder and Hand (DASH) and Patient-Rated Elbow Evaluation (PREE) scores. Results: All patients were male, with no significant differences in the mean age, percentages of dominant hands affected, or Workers’ Compensation cases between groups. There were also no differences in the final outcomes (at two years) between the two groups (p = 0.4 for ASES pain score, p = 0.10 for ASES function score, p = 0.3 for DASH score, and p = 0.4 for PREE score). In addition, there were no differences in isometric extension, pronation, or supination strength at more than one year. A 10% advantage in final isometric flexion strength was seen in the patients treated with the double-incision technique (104% versus 94% in the single-incision group; p = 0.01). There were no differences in the rate of strength recovery. The single-incision technique was associated with more early transient neurapraxias of the lateral antebrachial cutaneous nerve (nineteen of forty-seven versus three of forty-three in the double-incision group, p < 0.001). There were four reruptures, all of which were related to patient noncompliance or reinjury during the early postoperative period and appeared to be unrelated to the fixation technique (p = 0.3). Conclusions: There were no significant differences in outcomes between the single and double-incision distal biceps repair techniques other than a 10% advantage in final flexion strength with the latter. Most complications were minor, with a significantly greater prevalence in the single-incision group. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


  • Biomechanical Analysis of Fixation of Middle Third Fractures of the Clavicle

    by Darren S Drosdowech, Stuart E E Manwell, Louis M Ferreira, Danny P Goel, Kenneth J Faber, James A Johnson

    This biomechanical study compares four different techniques of fixation of middle third clavicular fractures. Twenty fresh-frozen clavicles were randomized into four groups. Each group used a different fixation device (3.5 Synthes reconstruction plate, 3.5 Synthes limited contact dynamic compression plate, 3.5 Synthes locking compression plate, and 4.5 DePuy Rockwood clavicular pin). All constructs were mechanically tested in bending and torque modes both with and without a simulated inferior cortical defect. Bending load to failure was also conducted. The four groups were compared using an analysis of variance test. The plate constructs were stiffer than the pin during both pure bending and torque loads with or without an inferior cortical defect. Bending load to failure with an inferior cortical defect revealed that the reconstruction plate was weaker compared with the other three groups. The limited contact and locking plates were stiffer than the reconstruction plate but demonstrated statistical significance only with the cortical defect. As hypothesized, the 3.5 limited contact dynamic compression plate and 3.5 locking compression plate demonstrated the greatest resistance to bending and torque loads, especially in the presence of simulated comminution of a middle third clavicular fracture. The reconstruction plate demonstrated lower stiffness and strength values compared with the other plates, especially with a cortical defect, whereas the pin showed poor resistance to bending and torque loads in all modes of testing. This information may help surgeons to choose the most appropriate method of fixation when treating fractures of the middle third of the clavicle.


  • Open Access

    Metastatic breast carcinoma of the coracoid process: two case reports

    by Eric C Benson, Darren S Drosdowech

    The coracoid process of the scapula is a rare site of involvement for metastatic disease or for primary tumors. We are unaware of any reports in the literature of pathologic coracoid process fractures and only one report of metastatic disease to the coracoid.


  • Periarticular Neurofibroma of the Shoulder

    by Danny P. Goel, Darren S. Drosdowech, R.G. Turner, Abdel-Rahman Lawendy, Gregory Garvin

    A thirty-eight-year-old woman presented with a two-year history of atraumatic pain in the left shoulder. The pain was insidious in onset, diffuse and dull, nonradiating, and nonprogressive. The patient reported that she did not have pain at rest but experienced pain with any activity and at night, particularly when lying on her left side. She otherwise felt well. Constitutional symptoms were absent, as were proximal pain or neurological symptoms. She had anteromedial elbow pain but no symptoms in any other joint.


  • Open Access

    Rotational strength, range of motion, and function in people with unaffected shoulders from various stages of life

    by Jean-Sébastien Roy, Joy C MacDermid, Kirsty Usher Boyd, Kenneth J Faber, Darren Drosdowech, George S Athwal

    Different measurements are used to assess shoulder function, including range of motion, strength, functional performance and self-report function. To understand disablement, it is necessary to understand the relationship between impairments and function in persons without shoulder problems. This study was conducted to enhance existing comparative data in subjects without upper extremity pathology, and to assess the relationships between impairments (range of motion, strength) and self-reported or measured function/disability. The impact of age, gender and dominance was determined. Two-hundred ninety-four subjects with unaffected shoulders were recruited. The subjects (mean age: 37 years old) were divided into three subgroups, 18–39, 40–59, and over 60 years of age. During a single session, at least two of the following variables were measured: self-reported function (shoulder disability scales), range of motion, isometric rotational strength, or upper limb functional performance (FIT-HaNSA). Two-way analysis of variance was used to determine, for each variable, the effects of age and gender. The relationship between the outcomes was established using Pearson product correlations. Men were significantly stronger than women for all age categories. There was an age-related decline in strength in men in the over-60 age category. Significant negative correlations between strength and range of motion were demonstrated (-0.22 <r < -0.32). Women had a significantly higher range of motion than men for external rotation in the 40–59 age category. Furthermore, the subjects in the over-60 age category experienced a decrease of range of motion. There was minimal disability reported in all age groups on self-report scales. Only the Simple Shoulder Test demonstrated significant decreases in the over-60 age category and correlated with age (r = -0.202). Self-reported disability was low in individuals without upper extremity problems, although recruitment of such individuals was difficult in the older age groups due to the high prevalence of shoulder pathology. A low correlation between self-report disability and strength/range of motion in these unaffected subjects reflects the lack of disability reported by all subjects without pathology despite normal variations in strength and motion.


  • Open Reduction and Internal Fixation of Proximal Humerus Fractures

    by Darren S. Drosdowech, Kenneth J. Faber, George S. Athwal


  • COMMINUTED RADIAL HEAD FRACTURES TREATED WITH A MODULAR METALLIC RADIAL HEAD ARTHROPLASTY

    by Ruby Grewal, Joy C. Macdermid, Kenneth J. Faber, Darren S. Drosdowech, Graham J.W. King

    Purpose of this study was to evaluate the two-year outcomes and the rate of recovery of a closely followed cohort of patients in whom an unreconstructible radial head fracture had been treated with a modular metallic prosthesis....


  • Comminuted Radial Head Fractures Treated with a Modular Metallic Radial Head ArthroplastyStudy of Outcomes

    by Ruby Grewal, Joy C. MacDermid, Kenneth J. Faber, Darren S. Drosdowech, Graham J.W. King

    Background: Comminuted fractures of the radial head are challenging to treat with open reduction and internal fixation. Radial head arthroplasty is an alternative treatment with results that compare favorably with those reported after open reduction and internal fixation of similar fractures. The purpose of this study was to evaluate the two-year outcomes and the rate of recovery of a closely followed cohort of patients in whom an unreconstructible radial head fracture had been treated with a modular metallic prosthesis. Methods: Twenty-six patients (seventeen female and nine male; mean age, fifty-four years) with an unreconstructible comminuted radial head fracture and associated elbow injuries were treated with a modular metallic radial head arthroplasty. Patients who had presented more than four weeks following the injury or had had the radial head arthroplasty as a second-stage or salvage procedure were excluded. Of the twenty-six patients, twenty-two had an associated elbow dislocation, and thirteen of them also had an associated fracture of the coronoid process. Patients were prospectively followed at three, six, twelve, and twenty-four months. Self-reported limb function, general health, range of motion, and isometric strength were assessed by an independent observer. Results: Following treatment of the injury, significant decreases in self-reported and measured impairments were noted over time, with the majority of the recovery occurring by six months and little further recovery noted between six and twenty-four months. There were slight-to-moderate deficits in the range of motion and strength compared with the values on the contralateral, unaffected side. Patient satisfaction was high at three months and remained high at two years. All elbow joints remained stable, no implant required revision, and there was no evidence of overstuffing of the joint. Mild osteoarthritis was seen in five (19%) of the twenty-six patients. Conclusions: An arthroplasty with a modular metallic radial head is a safe and effective option for the treatment of unreconstructible radial head fractures associated with other elbow injuries. Recovery primarily occurs by six months, with minimal additional improvements over the next eighteen months. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.