Jing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jing Li has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mingli Wu
Beijing Jiaotong University
7 shared publications - Qiujiang Liu
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
6 shared publications - Kejian Song
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
2 shared publications Marta Molinas
2 shared publications- Marta Molinas
Department of Engineering Cybernetics, Norwegian University of Science and Technology, Norway
2 shared publications Qiujiang Liu
School of Electrical Engineering, Beijing Jiaotong University, Beijing, China
2 shared publications
Latest Publications
- 28 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21, 1-6
The Small-Signal Stability Analysis of the Interacted Co-Phase Traction Power Supply System in Electric Railway
The continuous co-phase traction power supply system (CC-TPSS) introduces a large number of power electronic devices, which have poor response to disturbances and bring a series of stability problems such as weak electrical support and multimodal oscillations. To address this problem, this paper develops the small-signal impedance model of the static power converter (SPC) with fixed voltage control. Then the stability of CC-TPSS-network-train interacted system is analyzed using the impedance ratio of SPC impedance to train impedance. And the theoretical analysis is validated by time-domain simulation.
- 28 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 21, 1-6
The Small-Signal Stability Analysis of the Interacted Co-Phase Traction Power Supply System in Electric Railway
The continuous co-phase traction power supply system (CC-TPSS) introduces a large number of power electronic devices, which have poor response to disturbances and bring a series of stability problems such as weak electrical support and multimodal oscillations. To address this problem, this paper develops the small-signal impedance model of the static power converter (SPC) with fixed voltage control. Then the stability of CC-TPSS-network-train interacted system is analyzed using the impedance ratio of SPC impedance to train impedance. And the theoretical analysis is validated by time-domain simulation.
- Open Access
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 227024-227035
Hybrid Power Quality Compensation System for Electric Railway Supplied by the Hypotenuse of a Scott Transformer
To solve the three-phase unbalance and reactive power problems in the electric railway power supply system, this paper proposes a Scott transformer based hypotenuse hybrid traction power system (Scott-HHPS). Compared with other co-phase traction power supply systems, the Scott-HHPS could achieve the same compensation objective with smaller active compensation capacity. The paper analyzes the basic principle and makes a comparison between the Scott-HHPS and typical co-phase power supply system. The mathematical relationships among the load current, power factor and capacity demand in condition of power factor variation and regenerative braking are analyzed. In order to further reduce the compensation capacity of the Scott-HHPS, the partial compensation strategy in respect to the index of power factor and unbalance is proposed. Besides, an instantaneous current detection method based on the theorem of conservation of power is adopted to simplify the control algorithms. Simulations and experiments are both constructed and the results demonstrate that the Scott-HHPS can effectively improve the power quality in the electric railway power supply system.
- 16 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 227024-227035
Open AccessHybrid Power Quality Compensation System for Electric Railway Supplied by the Hypotenuse of a Scott Transformer
To solve the three-phase unbalance and reactive power problems in the electric railway power supply system, this paper proposes a Scott transformer based hypotenuse hybrid traction power system (Scott-HHPS). Compared with other co-phase traction power supply systems, the Scott-HHPS could achieve the same compensation objective with smaller active compensation capacity. The paper analyzes the basic principle and makes a comparison between the Scott-HHPS and typical co-phase power supply system. The mathematical relationships among the load current, power factor and capacity demand in condition of power factor variation and regenerative braking are analyzed. In order to further reduce the compensation capacity of the Scott-HHPS, the partial compensation strategy in respect to the index of power factor and unbalance is proposed. Besides, an instantaneous current detection method based on the theorem of conservation of power is adopted to simplify the control algorithms. Simulations and experiments are both constructed and the results demonstrate that the Scott-HHPS can effectively improve the power quality in the electric railway power supply system.
- Open Access
- 9 November 2020
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 8
Analysis of Harmonic Resonance for Locomotive and Traction Network Interacted System Considering the Frequency-Domain Passivity Properties of the Digitally Controlled Converter
Harmonic resonance is a kind of oscillatory instability phenomenon occurring in the electric railway. To investigate this problem, the frequency-domain model of the single-phase voltage source converter for locomotives is derived based on the transfer function of the current control loop. The equivalent circuit of the traction network is also included in this frequency-domain model. Particularly, the time delay and zero-order-holder effect of the digital pulse width modulation are taken into consideration in order to obtain more accurate a model of the digital controller. After that, the harmonic resonance of the locomotive-network system is assessed through the passivity properties of the interacted frequency-domain impedance model. Finally, the effectiveness of the theoretical analysis is demonstrated by simulations and experiments. As a result, the harmonic resonance can be predicted before a new electric railway is put into use so that some mitigation measures can be taken in advance.
- 9 November 2020
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 8
Open AccessAnalysis of Harmonic Resonance for Locomotive and Traction Network Interacted System Considering the Frequency-Domain Passivity Properties of the Digitally Controlled Converter
Harmonic resonance is a kind of oscillatory instability phenomenon occurring in the electric railway. To investigate this problem, the frequency-domain model of the single-phase voltage source converter for locomotives is derived based on the transfer function of the current control loop. The equivalent circuit of the traction network is also included in this frequency-domain model. Particularly, the time delay and zero-order-holder effect of the digital pulse width modulation are taken into consideration in order to obtain more accurate a model of the digital controller. After that, the harmonic resonance of the locomotive-network system is assessed through the passivity properties of the interacted frequency-domain impedance model. Finally, the effectiveness of the theoretical analysis is demonstrated by simulations and experiments. As a result, the harmonic resonance can be predicted before a new electric railway is put into use so that some mitigation measures can be taken in advance.
- 28 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (6) , 4801-4811
Frequency-Scanning Harmonic Generator for (Inter)Harmonic Impedance Tests and Its Implementation in Actual 2 × 25 kV Railway Systems
Measurements of (inter)harmonic impedances of the traction power supply system (TPSS) play important roles in the validation of TPSS modeling, suppression of resonances, stability analysis of locomotives converters, etc. A harmonic generator (HG) and its construction are proposed in this article to directly measure the impedance of TPSSs. Compared to other experimental setups, the HG can emit a fully controlled single-tone (inter)harmonic current at the high voltage level in a wide frequency range, i.e., at least covering 150-3750 Hz. Field tests have been carried out in the actual 2 × 25 kV railway considering the influence of locations and lengths that are scarcely presented in existing literatures. Both the implementation process and test waveforms have verified the effectiveness and feasibility of the HG. The test results, which denotes that locations do not change the resonant frequency while railway lengths will shift resonant frequencies distinctly, can be a basis for developing techniques aimed to improve the power quality.
- 28 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (6) , 4801-4811
Frequency-Scanning Harmonic Generator for (Inter)Harmonic Impedance Tests and Its Implementation in Actual 2 × 25 kV Railway Systems
Measurements of (inter)harmonic impedances of the traction power supply system (TPSS) play important roles in the validation of TPSS modeling, suppression of resonances, stability analysis of locomotives converters, etc. A harmonic generator (HG) and its construction are proposed in this article to directly measure the impedance of TPSSs. Compared to other experimental setups, the HG can emit a fully controlled single-tone (inter)harmonic current at the high voltage level in a wide frequency range, i.e., at least covering 150-3750 Hz. Field tests have been carried out in the actual 2 × 25 kV railway considering the influence of locations and lengths that are scarcely presented in existing literatures. Both the implementation process and test waveforms have verified the effectiveness and feasibility of the HG. The test results, which denotes that locations do not change the resonant frequency while railway lengths will shift resonant frequencies distinctly, can be a basis for developing techniques aimed to improve the power quality.
- Open Access
- 13 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 71685-71693
Influence of the Power Source on the Impedance-Frequency Estimation of the 2 × 25 kV Electrified Railway
The simple increasing impedance model is usually adopted by calculation or computer simulation to represent the harmonic behaviors of the power source in the studies of impedance-frequency characteristics (IFCs) of the traction power supply system (TPSS) in electrified railways. However, this model is a little rough and sometimes even introduces inevitable errors in stability analysis, resonance estimation, and filter design, etc. This paper proposes an improved calculation method based on field tests to evaluate the impact of the power source on the equivalent harmonic impedance at the pantograph terminal seen from trains. Then two field tests are presented in detail to verify the difference between the classical method and the proposed method. The compared results proved the effectiveness of the analysis of this paper. Furthermore, the accuracy of the 2×25 kV electrified railway’s impedance-frequency estimation was significantly improved through the proposed calculation method.
- 13 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 71685-71693
Open AccessInfluence of the Power Source on the Impedance-Frequency Estimation of the 2 × 25 kV Electrified Railway
The simple increasing impedance model is usually adopted by calculation or computer simulation to represent the harmonic behaviors of the power source in the studies of impedance-frequency characteristics (IFCs) of the traction power supply system (TPSS) in electrified railways. However, this model is a little rough and sometimes even introduces inevitable errors in stability analysis, resonance estimation, and filter design, etc. This paper proposes an improved calculation method based on field tests to evaluate the impact of the power source on the equivalent harmonic impedance at the pantograph terminal seen from trains. Then two field tests are presented in detail to verify the difference between the classical method and the proposed method. The compared results proved the effectiveness of the analysis of this paper. Furthermore, the accuracy of the 2×25 kV electrified railway’s impedance-frequency estimation was significantly improved through the proposed calculation method.
- Open Access
- 16 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 52395-52403
Field Tests for Evaluating the Inherent High-Order Harmonic Resonance of Traction Power Supply Systems Up to 5000 Hz
The inherent resonant frequency of a traction power supply system (TPSS) needs to be accurately identified in order to provide crucial information for resonance suppression, safe operation, and system optimization of electrified railways. In this paper, implementation of experiments was carried out in actual railway systems to evaluate the inherent harmonic resonances of the TPSS. The field tests were based on a harmonic generator (HG) constructed with cascaded H-bridge converters (CHBCs). Compared to other experimental setups, the field tests of this paper, which were performed in the 25kV practical system, can provide straightforward results in a wide frequency range up to 5000 Hz. Such a wide frequency range is necessary for assessing and taking effective measures to address the harmonic resonance problem. The results of this paper will supply valuable data for the modeling of TPSSs and the stability analysis of train converters contributing to improvement of the power quality of electric railways.
- 16 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 52395-52403
Open AccessField Tests for Evaluating the Inherent High-Order Harmonic Resonance of Traction Power Supply Systems Up to 5000 Hz
The inherent resonant frequency of a traction power supply system (TPSS) needs to be accurately identified in order to provide crucial information for resonance suppression, safe operation, and system optimization of electrified railways. In this paper, implementation of experiments was carried out in actual railway systems to evaluate the inherent harmonic resonances of the TPSS. The field tests were based on a harmonic generator (HG) constructed with cascaded H-bridge converters (CHBCs). Compared to other experimental setups, the field tests of this paper, which were performed in the 25kV practical system, can provide straightforward results in a wide frequency range up to 5000 Hz. Such a wide frequency range is necessary for assessing and taking effective measures to address the harmonic resonance problem. The results of this paper will supply valuable data for the modeling of TPSSs and the stability analysis of train converters contributing to improvement of the power quality of electric railways.
- 16 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (2) , 746-756
Measurement of Impedance-Frequency Property of Traction Network Using Cascaded H-Bridge Converters: Device Design and On-Site Test
To investigate the harmonic resonance in electric railways, determination of the traction network impedance using a utility instrument is an important and challenging task. This article presents a novel industrial test device which can directly measure the impedance of the actual traction network which is the power source of the railway. The structure arrangement and the parameter design are accomplished to meet the requirements for high-voltage level and strong anti-electromagnetic interference capability. Following this, frequency-dependent impedance measurement is implemented through the injection of controlled harmonic currents using the cascaded H-bridge converters. Furthermore, the power flow analysis is carried out to demonstrate that this device does not need any additional power source and can generate harmonic power. In a new-built railway, this device has been adopted to conduct the on-site test of the traction network impedance. Then, the multi-conductor simulation model is established for the purpose of mutual verification between the field test result and simulation result. Furthermore, the on-site test results can be applied to determine the resonance frequency before a nenw-built line is put into use so that any harmonic resonance can be avoided by taking effective measures in advance.
- 16 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (2) , 746-756
Measurement of Impedance-Frequency Property of Traction Network Using Cascaded H-Bridge Converters: Device Design and On-Site Test
To investigate the harmonic resonance in electric railways, determination of the traction network impedance using a utility instrument is an important and challenging task. This article presents a novel industrial test device which can directly measure the impedance of the actual traction network which is the power source of the railway. The structure arrangement and the parameter design are accomplished to meet the requirements for high-voltage level and strong anti-electromagnetic interference capability. Following this, frequency-dependent impedance measurement is implemented through the injection of controlled harmonic currents using the cascaded H-bridge converters. Furthermore, the power flow analysis is carried out to demonstrate that this device does not need any additional power source and can generate harmonic power. In a new-built railway, this device has been adopted to conduct the on-site test of the traction network impedance. Then, the multi-conductor simulation model is established for the purpose of mutual verification between the field test result and simulation result. Furthermore, the on-site test results can be applied to determine the resonance frequency before a nenw-built line is put into use so that any harmonic resonance can be avoided by taking effective measures in advance.
- Open Access
- 8 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 111539-111558
A Three-Phase to Single-Phase AC-DC-AC Topology Based on Multi-Converter in AC Electric Railway Application
An AC-DC-AC topology based on multi-converter is proposed in this paper. It can match the capacity of the converter for high voltage and large power applications. This structure is not only suitable for solving the power quality problems of electrified railways, but also has its own superiorities. Its architecture and advantages in the traction application are analyzed in depth, and the design calculation of the main elements is presented. The control system of the proposed topology is designed, where dc current feedforward control is adopted to relieve the impact of the load mutation on the system. Its modular structure and simple current sharing control provide convenience for the capacity expansion. The software simulation and experiment based on a 45kVA prototype validate the proposed structure, and they are all compared with the traditional power supply systems. The simulation results indicate that this topology can not only satisfy the voltage and power requirements of traction load and solve the power quality problems, but also have its own superiorities in the application of electrified railways. The experimental results verify the correctness and validity of the scheme.
- 8 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 111539-111558
Open AccessA Three-Phase to Single-Phase AC-DC-AC Topology Based on Multi-Converter in AC Electric Railway Application
An AC-DC-AC topology based on multi-converter is proposed in this paper. It can match the capacity of the converter for high voltage and large power applications. This structure is not only suitable for solving the power quality problems of electrified railways, but also has its own superiorities. Its architecture and advantages in the traction application are analyzed in depth, and the design calculation of the main elements is presented. The control system of the proposed topology is designed, where dc current feedforward control is adopted to relieve the impact of the load mutation on the system. Its modular structure and simple current sharing control provide convenience for the capacity expansion. The software simulation and experiment based on a 45kVA prototype validate the proposed structure, and they are all compared with the traditional power supply systems. The simulation results indicate that this topology can not only satisfy the voltage and power requirements of traction load and solve the power quality problems, but also have its own superiorities in the application of electrified railways. The experimental results verify the correctness and validity of the scheme.
- Open Access
- 22 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 68119-68131
Assessing High-Order Harmonic Resonance in Locomotive-Network Based on the Impedance Method
Many new types of locomotives are put to use in electric railway systems, resulting in instability problems, such as high-order harmonic resonance occurring as a consequence of the interaction between the electrical locomotive (including electrical multiple units) and the traction network. In order to investigate this problem, this paper adopts the impedance-based approach to analyze the stability properties of the system interaction. The detailed impedance of the traction network is obtained by taking its distributed parameters into account. Then the locomotive converter with single-phase transient current control algorithm (TCCA), which can represent the locomotive when performing the impedance-based stability analysis, is modeled as the dq-frame impedance by single-phase dq decomposition. By plotting bode diagrams of the impedance for the traction network and the locomotive separately, and calculating the phase margin at the intersection point of the magnitude of the two impedances, the stability of the locomotive-network system is evaluated and thus the high-order harmonic resonance can be predicted. Moreover, a time-domain model of locomotive-network systems is established in this paper, which can reproduce the high-order harmonic resonance in the time domain as a first validation step of the analysis. Finally, a field test in a traction substation of the Beijing-Harbin Railway is carried out to finally validate the effectiveness of the proposed method. The stability analysis method in this paper is simple and effective without the need for a complex calculation of some norms or eigenvalues. As a result, high-order harmonic resonance can be predicted before a new type of locomotive is put into use.
- 22 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 68119-68131
Open AccessAssessing High-Order Harmonic Resonance in Locomotive-Network Based on the Impedance Method
Many new types of locomotives are put to use in electric railway systems, resulting in instability problems, such as high-order harmonic resonance occurring as a consequence of the interaction between the electrical locomotive (including electrical multiple units) and the traction network. In order to investigate this problem, this paper adopts the impedance-based approach to analyze the stability properties of the system interaction. The detailed impedance of the traction network is obtained by taking its distributed parameters into account. Then the locomotive converter with single-phase transient current control algorithm (TCCA), which can represent the locomotive when performing the impedance-based stability analysis, is modeled as the dq-frame impedance by single-phase dq decomposition. By plotting bode diagrams of the impedance for the traction network and the locomotive separately, and calculating the phase margin at the intersection point of the magnitude of the two impedances, the stability of the locomotive-network system is evaluated and thus the high-order harmonic resonance can be predicted. Moreover, a time-domain model of locomotive-network systems is established in this paper, which can reproduce the high-order harmonic resonance in the time domain as a first validation step of the analysis. Finally, a field test in a traction substation of the Beijing-Harbin Railway is carried out to finally validate the effectiveness of the proposed method. The stability analysis method in this paper is simple and effective without the need for a complex calculation of some norms or eigenvalues. As a result, high-order harmonic resonance can be predicted before a new type of locomotive is put into use.