Dimas Okky Anggriawan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dimas Okky Anggriawan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Eka Prasetyono
Politeknik Elektronika Negeri Surabaya
3 shared publications - Anang Tjahjono
Department of Electrical Engineering, Politeknik Elektronika Negeri Surabaya, Jalan Raya ITS, Surabaya, Indonesia
2 shared publications Eka Prasetyono
Politeknik Elektronika Negeri Surabaya
2 shared publications- Epyk Sunarno
Politeknik Elektronika Negeri Surabaya
2 shared publications Suhariningsih Suhariningsih
Politeknik Elektronika Negeri Surabaya
2 shared publications- Ahmad Dzihan Alifi
Politeknik Elektronika Negeri Surabaya
1 shared publication
Latest Publications
- Open Access
- 1 December 2024
- Published by Universitas Ahmad Dahlan in TELKOMNIKA (Telecommunication Computing Electronics and Control)
- Vol. 22 (6) , 1564-1572
Multi-step constant current-constant voltage charging method to improve CC-CV method on lead acid batteries
Multi-step constant current-constant voltage charging method to improve CC-CV method on lead acid batteries
- 1 December 2024
- Published by Universitas Ahmad Dahlan in TELKOMNIKA (Telecommunication Computing Electronics and Control)
- Vol. 22 (6) , 1564-1572
Open AccessMulti-step constant current-constant voltage charging method to improve CC-CV method on lead acid batteries
Multi-step constant current-constant voltage charging method to improve CC-CV method on lead acid batteries
- Open Access
- 28 October 2023
- Published by Politeknik Negeri Balikpapan in JTT (Jurnal Teknologi Terpadu)
- Vol. 11 (2) , 303-310
Implementation of Fast Fourier Transform and Artificial Neural Network in Series Arc Fault Identification and Protection System on DC Bus Microgrid
A microgrid is a cluster of electrical sources and loads that are interconnected and synchronized. Microgrid operation is typically divided into two modes, isolated or connected to the grid with a single or standalone control system. In this context, it can enhance the reliability and quality of electricity supply for connected customers. When using a microgrid system, it is important to consider the risk of series arc faults. Series arc faults are sudden bursts of flames resulting from ionization of gas between two electrode gaps. These faults can occur due to manufacturing defects, installation Errors, aging, or corrosion on conductor rods, leading to imperfect connections. Detecting series arc faults in DC microgrid system operations can be challenging using standard protective devices. Failure in the protection system can pose risks of fire, electrical shock hazards, and power loss in the DC microgrid.Therefore, a device has been designed to detect series arc faults by utilizing the fast Fourier transform method and artificial neural network, which function to analyze DC signal and make decisions when faults occur by examining the average sum of current frequency values during normal and fault conditions. In this study, the average sum of current frequency values during normal conditions was found to range from 0.35437 to 0.36906 A, while during fault conditions, it ranged from 0.21450 to 0.22793 A, with an average protection identification time of 1087 ms and an ANN output accuracy of 99.98%.
- 28 October 2023
- Published by Politeknik Negeri Balikpapan in JTT (Jurnal Teknologi Terpadu)
- Vol. 11 (2) , 303-310
Open AccessImplementation of Fast Fourier Transform and Artificial Neural Network in Series Arc Fault Identification and Protection System on DC Bus Microgrid
A microgrid is a cluster of electrical sources and loads that are interconnected and synchronized. Microgrid operation is typically divided into two modes, isolated or connected to the grid with a single or standalone control system. In this context, it can enhance the reliability and quality of electricity supply for connected customers. When using a microgrid system, it is important to consider the risk of series arc faults. Series arc faults are sudden bursts of flames resulting from ionization of gas between two electrode gaps. These faults can occur due to manufacturing defects, installation Errors, aging, or corrosion on conductor rods, leading to imperfect connections. Detecting series arc faults in DC microgrid system operations can be challenging using standard protective devices. Failure in the protection system can pose risks of fire, electrical shock hazards, and power loss in the DC microgrid.Therefore, a device has been designed to detect series arc faults by utilizing the fast Fourier transform method and artificial neural network, which function to analyze DC signal and make decisions when faults occur by examining the average sum of current frequency values during normal and fault conditions. In this study, the average sum of current frequency values during normal conditions was found to range from 0.35437 to 0.36906 A, while during fault conditions, it ranged from 0.21450 to 0.22793 A, with an average protection identification time of 1087 ms and an ANN output accuracy of 99.98%.
- Open Access
- 30 April 2023
- Published by Politeknik Negeri Batam in JURNAL INTEGRASI
- Vol. 15 (1) , 63-70
Rancang Bangun 3 Phase Energy Meter Untuk Analisis Kualitas Daya Di Industri
The quality of electric power is one of the most important things in the industrial world, with good power quality, industrial efficiency will also increase which will result in savings in production costs. Energy consumption must also be monitored in such a way for the purposes of analyzing electrical energy efficiency. Therefore, the author designed a tool called a 3 phase energy meter that can monitor energy consumption and power quality for industry with a 3 phase electrical system. The 3 phase energy meter is equipped with an IoT system so that the observation of the measurement results of every electrical machine system in the industry can be done at one point without having to go to the location. The hope is that with the 3 phase energy meter, it can improve production efficiency through power quality analysis.
- 30 April 2023
- Published by Politeknik Negeri Batam in JURNAL INTEGRASI
- Vol. 15 (1) , 63-70
Open AccessRancang Bangun 3 Phase Energy Meter Untuk Analisis Kualitas Daya Di Industri
The quality of electric power is one of the most important things in the industrial world, with good power quality, industrial efficiency will also increase which will result in savings in production costs. Energy consumption must also be monitored in such a way for the purposes of analyzing electrical energy efficiency. Therefore, the author designed a tool called a 3 phase energy meter that can monitor energy consumption and power quality for industry with a 3 phase electrical system. The 3 phase energy meter is equipped with an IoT system so that the observation of the measurement results of every electrical machine system in the industry can be done at one point without having to go to the location. The hope is that with the 3 phase energy meter, it can improve production efficiency through power quality analysis.
- Open Access
- 28 March 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (2) , 888-898
Global Maximum Power Point Tracking of PV Array Under Non-Uniform Irradiation Condition Using Adaptive Velocity Particle Swarm Optimization
Global Maximum Power Point Tracking of PV Array Under Non-Uniform Irradiation Condition Using Adaptive Velocity Particle Swarm Optimization
- 28 March 2020
- Published by Insight Society in International Journal on Advanced Science, Engineering and Information Technology
- Vol. 10 (2) , 888-898
Open AccessGlobal Maximum Power Point Tracking of PV Array Under Non-Uniform Irradiation Condition Using Adaptive Velocity Particle Swarm Optimization
Global Maximum Power Point Tracking of PV Array Under Non-Uniform Irradiation Condition Using Adaptive Velocity Particle Swarm Optimization
- Open Access
- 15 June 2019
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 7 (1) , 243-260
A Full-Bridge Bidirectional DC-DC Converter with Fuzzy Logic Voltage Control for Battery Energy Storage System
Renewable energy sources require an energy storage system because its are fluctuating and electricity producing at certain times, even sometimes not in accordance with the needs of the load. To maintain continuity of electricity, smart battery energy storage system is needed. Therefore, this paper of a full-bridge bidirectional DC-DC Converter (FB-BDC) with Fuzzy Logic Control (FLC) is designed and implemented for battery energy storage application. The FLC has error and delta error of voltage level as input and duty cycle of FB-BDC as output. The FB-BDC is controlled by a microcontroller ARM Cortex-M4F STM32F407VG for voltage mode control. The FB-BDC topology is selected becuase battery storage system needed isolated and need high voltage ratio both for step-up and step-down. The main purpose of FB-BDC to perform bidirectional energy transfer both of DC-Bus and battery. Moreover, FB-BDC controls the DC-Bus voltage according to referenced value. The power flow and voltage on DC-Bus is controlled by FLC with voltage mode control. The experiment result shows the ability of FLCÂ voltage mode control to control FB-BDC on regulate charging voltage with an error 1% and sharing voltage 1.5% form referenced value.
- 15 June 2019
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 7 (1) , 243-260
Open AccessA Full-Bridge Bidirectional DC-DC Converter with Fuzzy Logic Voltage Control for Battery Energy Storage System
Renewable energy sources require an energy storage system because its are fluctuating and electricity producing at certain times, even sometimes not in accordance with the needs of the load. To maintain continuity of electricity, smart battery energy storage system is needed. Therefore, this paper of a full-bridge bidirectional DC-DC Converter (FB-BDC) with Fuzzy Logic Control (FLC) is designed and implemented for battery energy storage application. The FLC has error and delta error of voltage level as input and duty cycle of FB-BDC as output. The FB-BDC is controlled by a microcontroller ARM Cortex-M4F STM32F407VG for voltage mode control. The FB-BDC topology is selected becuase battery storage system needed isolated and need high voltage ratio both for step-up and step-down. The main purpose of FB-BDC to perform bidirectional energy transfer both of DC-Bus and battery. Moreover, FB-BDC controls the DC-Bus voltage according to referenced value. The power flow and voltage on DC-Bus is controlled by FLC with voltage mode control. The experiment result shows the ability of FLCÂ voltage mode control to control FB-BDC on regulate charging voltage with an error 1% and sharing voltage 1.5% form referenced value.
- Open Access
- 15 June 2019
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 7 (1) , 71-82
Load Identification Using Harmonic Based on Probabilistic Neural Network
Due to increase power quality which are caused by harmonic distortion it could be affected malfunction electrical equipment. Therefore, identification of harmonic loads become important attention in the power system. According to those problems, this paper proposes a Load Identification using harmonic based on probabilistic neural network (PNN). Harmonic is obtained by experiment using prototype, which it consists of microcontroller and current sensor. Fast Fourier Transform (FFT) method to analyze of current waveform on loads become harmonic load data. PNN is used to identify the type of load. To load identification, PNN is trained to get the new weight. Testing is conducted To evaluate of the accuracy of the PNN from combination of four loads. The results demonstrate that this method has high accuracy to determine type of loads based on harmonic load
- 15 June 2019
- Published by EMITTER International Journal of Engineering Technology in EMITTER International Journal of Engineering Technology
- Vol. 7 (1) , 71-82
Open AccessLoad Identification Using Harmonic Based on Probabilistic Neural Network
Due to increase power quality which are caused by harmonic distortion it could be affected malfunction electrical equipment. Therefore, identification of harmonic loads become important attention in the power system. According to those problems, this paper proposes a Load Identification using harmonic based on probabilistic neural network (PNN). Harmonic is obtained by experiment using prototype, which it consists of microcontroller and current sensor. Fast Fourier Transform (FFT) method to analyze of current waveform on loads become harmonic load data. PNN is used to identify the type of load. To load identification, PNN is trained to get the new weight. Testing is conducted To evaluate of the accuracy of the PNN from combination of four loads. The results demonstrate that this method has high accuracy to determine type of loads based on harmonic load