Tong Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tong Su has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Lizhi Sheng
7 shared publicationsBaosheng Zhao
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
6 shared publicationsPengfei Qiang
6 shared publicationsYao Li
College of Optoelectronic Engineering, Xi’an Technological University, Xi’an 710021, China
6 shared publicationsNeng Xu
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
4 shared publicationsBo Wang
2 shared publications
Latest Publications
- Open Access
- 11 June 2025
- Published by Elsevier in Physics Letters B
- Vol. 868
Compton scattering X-ray imaging system for material detection through 3 mm aluminum shielding for potential future space application
- 11 June 2025
- Published by Elsevier in Physics Letters B
- Vol. 868
Open AccessCompton scattering X-ray imaging system for material detection through 3 mm aluminum shielding for potential future space application
- 4 December 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 39 (22)
Reconstruction of NICER-observed crab pulsar profiles during earth orbit using a semi-physical experimental system
X-ray pulsar navigation (XNAV) is a critical technique for spacecraft navigation in deep space, capitalizing on the precise timing properties of X-ray pulsars. Despite extensive research in pulsar observations, signal processing algorithms, and data fusion algorithms, existing technology suffers from immature algorithms, leading to positioning errors and inaccurate accuracy, which significantly hampers navigation effectiveness. In order to facilitate more refined research into navigation algorithms, this paper proposes a method that utilizes a semi-physical experimental system for profile reconstruction, with the goal of simulating pulsar behavior on Earth. By integrating precise X-ray pulse generation, detection systems and signal processing, the reconstruction of Crab pulsar profiles has been successfully achieved. These reconstructed profiles exhibit remarkably high fidelity with parameters disclosed by NASA, boasting a profile reconstruction coefficient of 0.99849. The mean error between parameters provided by NASA and those derived from semi-physical experimentation is 17.11[ ]ns, with a standard deviation of 254.59[ ]ns. This validation confirms the feasibility and reliability of conducting experiments using the semi-physical simulation system. Such a system lays the groundwork for advancing pulsar navigation technology, facilitating improved spacecraft positioning and trajectory determination in deep space exploration endeavors.
- 4 December 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 39 (22)
Reconstruction of NICER-observed crab pulsar profiles during earth orbit using a semi-physical experimental system
X-ray pulsar navigation (XNAV) is a critical technique for spacecraft navigation in deep space, capitalizing on the precise timing properties of X-ray pulsars. Despite extensive research in pulsar observations, signal processing algorithms, and data fusion algorithms, existing technology suffers from immature algorithms, leading to positioning errors and inaccurate accuracy, which significantly hampers navigation effectiveness. In order to facilitate more refined research into navigation algorithms, this paper proposes a method that utilizes a semi-physical experimental system for profile reconstruction, with the goal of simulating pulsar behavior on Earth. By integrating precise X-ray pulse generation, detection systems and signal processing, the reconstruction of Crab pulsar profiles has been successfully achieved. These reconstructed profiles exhibit remarkably high fidelity with parameters disclosed by NASA, boasting a profile reconstruction coefficient of 0.99849. The mean error between parameters provided by NASA and those derived from semi-physical experimentation is 17.11[ ]ns, with a standard deviation of 254.59[ ]ns. This validation confirms the feasibility and reliability of conducting experiments using the semi-physical simulation system. Such a system lays the groundwork for advancing pulsar navigation technology, facilitating improved spacecraft positioning and trajectory determination in deep space exploration endeavors.
- 1 January 2024
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 73 (4) , 040701-040701-7
Nanosecond pulse X-ray emission source based on ultrafast laser modulation
In response to the growing demand for miniaturized ultrafast pulsed X-ray sources in the fields of fundamental science and space applications, we design and develop an ultrafast pulsed X-ray generator based on a laser-modulated light source and a photoelectric cathode. This innovative technology addresses the limitations commonly encountered in traditional X-ray emission devices, such as low repetition rate, insufficient time stability, and suboptimal pulse characteristics.Our effort is to study and develop the ultrafast modulation control module for the pulsed X-ray generator. This effort results in achieving high levels of time accuracy and stability in ultrafast time-varying photon signals. Moreover, we successfully generate nanosecond pulsed X-rays by using a laser-controlled light source.Theoretically, we establish a comprehensive time response model for the pulsed X-ray generator in response to short pulses. This includes a thorough analysis of the time characteristics of the emitted pulsed X-rays in the time domain. Experimentally, we conduct a series of tests related to various time-related parameters of the laser-controlled light source. Additionally, we design and implemente an experimental test system for assessing the time characteristics of pulsed X-rays, by using an ultrafast scintillation detector.The experimental results clearly demonstrate that our pulsed X-ray generator achieves impressive capabilities, including high repetition rates (12.5 MHz), ultrafast pulses (4 ns), and exceptional time stability (400 ps) in X-ray emission. These results closely align with our established theoretical model. Compared with traditional modulation techniques, our system exhibits significant improvement in pulse time parameters, thereby greatly expanding its potential applications.This research provides a valuable insight into achieving ultra-high time stability and ultrafast pulsed X-ray emission sources. These advances will further enhance the capabilities of X-ray technology for scientific research and space applications.
- 1 January 2024
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 73 (4) , 040701-040701-7
Nanosecond pulse X-ray emission source based on ultrafast laser modulation
In response to the growing demand for miniaturized ultrafast pulsed X-ray sources in the fields of fundamental science and space applications, we design and develop an ultrafast pulsed X-ray generator based on a laser-modulated light source and a photoelectric cathode. This innovative technology addresses the limitations commonly encountered in traditional X-ray emission devices, such as low repetition rate, insufficient time stability, and suboptimal pulse characteristics.Our effort is to study and develop the ultrafast modulation control module for the pulsed X-ray generator. This effort results in achieving high levels of time accuracy and stability in ultrafast time-varying photon signals. Moreover, we successfully generate nanosecond pulsed X-rays by using a laser-controlled light source.Theoretically, we establish a comprehensive time response model for the pulsed X-ray generator in response to short pulses. This includes a thorough analysis of the time characteristics of the emitted pulsed X-rays in the time domain. Experimentally, we conduct a series of tests related to various time-related parameters of the laser-controlled light source. Additionally, we design and implemente an experimental test system for assessing the time characteristics of pulsed X-rays, by using an ultrafast scintillation detector.The experimental results clearly demonstrate that our pulsed X-ray generator achieves impressive capabilities, including high repetition rates (12.5 MHz), ultrafast pulses (4 ns), and exceptional time stability (400 ps) in X-ray emission. These results closely align with our established theoretical model. Compared with traditional modulation techniques, our system exhibits significant improvement in pulse time parameters, thereby greatly expanding its potential applications.This research provides a valuable insight into achieving ultra-high time stability and ultrafast pulsed X-ray emission sources. These advances will further enhance the capabilities of X-ray technology for scientific research and space applications.
- 2 July 2022
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 36 (20)
An optimized design of grid-controlled modulated X-ray source for space communication
- 2 July 2022
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 36 (20)
An optimized design of grid-controlled modulated X-ray source for space communication
- 1 January 2019
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 68 (4) , 040401-040401-9
X-ray transmission characteristics and potential communication application in plasma region
X射线具有波长短、光子能量高等特点, 有望在等离子体环境中实现信息的有效传输. 本文首先采用基于连续介质中的WKB分层法, 研究了黑障条件下, X射线在非均匀等离子体鞘套中的透过率特性, 仿真了不同等离子体电子密度和碰撞频率下X射线信号的透过率, 理论上证明了X射线可用于黑障区信息传输的可行性. 其次通过搭建环形扩散辉光放电等离子体发生器及实验验证系统, 进行了国内外首次X射线穿过等离子体鞘套的验证实验. 实验结果表明, 等离子体对X射线信号的透过率存在一定程度的衰减, 透过等离子体前后的X射线信号能谱轮廓相似度优于95.5%, 能谱峰值点的偏移量小于1.3%. 此外, 在原有理论模型的基础上, 考虑等离子中的粒子与X射线的碰撞、吸收效应, 优化了X射线在等离子体中的透过率模型, 与传统的理论方法相比, 该模型可对实验现象进行更好的解释. 同时计算了X射线在临近空间的透过率, 并分析了X射线通信所能达到的潜在指标. 这些结果有望为解决黑障区信号传输提供一定的理论与实验依据.
- 1 January 2019
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 68 (4) , 040401-040401-9
X-ray transmission characteristics and potential communication application in plasma region
X射线具有波长短、光子能量高等特点, 有望在等离子体环境中实现信息的有效传输. 本文首先采用基于连续介质中的WKB分层法, 研究了黑障条件下, X射线在非均匀等离子体鞘套中的透过率特性, 仿真了不同等离子体电子密度和碰撞频率下X射线信号的透过率, 理论上证明了X射线可用于黑障区信息传输的可行性. 其次通过搭建环形扩散辉光放电等离子体发生器及实验验证系统, 进行了国内外首次X射线穿过等离子体鞘套的验证实验. 实验结果表明, 等离子体对X射线信号的透过率存在一定程度的衰减, 透过等离子体前后的X射线信号能谱轮廓相似度优于95.5%, 能谱峰值点的偏移量小于1.3%. 此外, 在原有理论模型的基础上, 考虑等离子中的粒子与X射线的碰撞、吸收效应, 优化了X射线在等离子体中的透过率模型, 与传统的理论方法相比, 该模型可对实验现象进行更好的解释. 同时计算了X射线在临近空间的透过率, 并分析了X射线通信所能达到的潜在指标. 这些结果有望为解决黑障区信号传输提供一定的理论与实验依据.
- 20 October 2018
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 32 (29) , 1850355
Study of a high-precision pulsar angular position measuring method
- 20 October 2018
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 32 (29) , 1850355
Study of a high-precision pulsar angular position measuring method