Mabel Crescioni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mabel Crescioni has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
J. Daniel Twelker
Department of Ophthalmology and Vision Science, University of Arizona, Tucson, Arizona, United States College of Public Health, University of Arizona, Tucson, Arizona, United States
4 shared publicationsJoseph M. Miller
Department of Ophthalmology and Vision Science, The University of Arizona, Tucson, Arizona; College of Public Health, The University of Arizona, Tucson, Arizona; Optical Sciences Center, The University of Arizona, Tucson, Arizona
3 shared publications- Sonya Eremenco
Critical Path Institute, Tucson, USA
3 shared publications - Bill Byrom
Signant Health, London, UK
2 shared publications Cindy Howry
.assisTek, Scottsdale, AZ, USA
2 shared publicationsErin M. Harvey
Department of Ophthalmology and Vision Science, The University of Arizona, Tucson, Arizona; College of Public Health, The University of Arizona, Tucson, Arizona
2 shared publications
Latest Publications
- 1 January 2020
- Published by Elsevier in Ophthalmology
- Vol. 127 (1) , 27-37
A Randomized Noninferiority Trial of Wearing Adjustable Glasses versus Standard and Ready-made Spectacles among Chinese Schoolchildren
- 1 January 2020
- Published by Elsevier in Ophthalmology
- Vol. 127 (1) , 27-37
A Randomized Noninferiority Trial of Wearing Adjustable Glasses versus Standard and Ready-made Spectacles among Chinese Schoolchildren
- 1 July 2019
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 53 (4) , 441-445
Best Practices for Avoiding Paper Backup When Implementing Electronic Approaches to Patient-Reported Outcome Data Collection in Clinical Trials
Electronic data capture is fast becoming the preferred method of collecting patient-reported outcome (PRO) data in clinical trials. Data collection can be
- 1 July 2019
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 53 (4) , 441-445
Best Practices for Avoiding Paper Backup When Implementing Electronic Approaches to Patient-Reported Outcome Data Collection in Clinical Trials
Electronic data capture is fast becoming the preferred method of collecting patient-reported outcome (PRO) data in clinical trials. Data collection can be
- 1 July 2019
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 53 (4) , 431-440
Training on the Use of Technology to Collect Patient-Reported Outcome Data Electronically in Clinical Trials: Best Practice Recommendations from the ePRO Consortium
Electronic capture of patient-reported outcome (PRO) data has many advantages over paper-based data collection. Regulatory agencies have consistently suppo
- 1 July 2019
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 53 (4) , 431-440
Training on the Use of Technology to Collect Patient-Reported Outcome Data Electronically in Clinical Trials: Best Practice Recommendations from the ePRO Consortium
Electronic capture of patient-reported outcome (PRO) data has many advantages over paper-based data collection. Regulatory agencies have consistently suppo
- 1 May 2019
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 53 (3) , 318-323
Perceived Burden of Completion of Patient-Reported Outcome Measures in Clinical Trials: Results of a Preliminary Study
Understanding the perceived burden of clinical trial participation is an important element of patient-centric trial design and conduct. We report the results of a study to gain preliminary insights into the perceived burden associated with patient-reported outcome (PRO) data collection among a sample (n = 61) of volunteers from the general population including people with various health conditions resulting in chronic pain. Participants identified morning completion as more burdensome than completion of PRO measures in the evening. Weekly completion was perceived as less burdensome than daily, and twice-a-day more burdensome than once-a-day. Our results, while not generalizable in isolation, provide a valuable starting point to understand the complex construct of subject burden. This preliminary work is intended to be a catalyst for more in-depth research to better understand and predict burden and acceptable burden thresholds in clinical trials. Understanding subject burden is a vital component of human subject research that will be valuable in helping to inform future clinical trial designs.
- 1 May 2019
- Published by Springer Nature in Therapeutic Innovation & Regulatory Science
- Vol. 53 (3) , 318-323
Perceived Burden of Completion of Patient-Reported Outcome Measures in Clinical Trials: Results of a Preliminary Study
Understanding the perceived burden of clinical trial participation is an important element of patient-centric trial design and conduct. We report the results of a study to gain preliminary insights into the perceived burden associated with patient-reported outcome (PRO) data collection among a sample (n = 61) of volunteers from the general population including people with various health conditions resulting in chronic pain. Participants identified morning completion as more burdensome than completion of PRO measures in the evening. Weekly completion was perceived as less burdensome than daily, and twice-a-day more burdensome than once-a-day. Our results, while not generalizable in isolation, provide a valuable starting point to understand the complex construct of subject burden. This preliminary work is intended to be a catalyst for more in-depth research to better understand and predict burden and acceptable burden thresholds in clinical trials. Understanding subject burden is a vital component of human subject research that will be valuable in helping to inform future clinical trial designs.
- Open Access
- 1 June 2018
- Published by Elsevier in Value in Health
- Vol. 21 (6) , 631-639
Selection of and Evidentiary Considerations for Wearable Devices and Their Measurements for Use in Regulatory Decision Making: Recommendations from the ePRO Consortium
- 1 June 2018
- Published by Elsevier in Value in Health
- Vol. 21 (6) , 631-639
Open AccessSelection of and Evidentiary Considerations for Wearable Devices and Their Measurements for Use in Regulatory Decision Making: Recommendations from the ePRO Consortium
- 1 October 2015
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 19 (5) , 435-440
Accuracy of the Spot and Plusoptix photoscreeners for detection of astigmatism
- 1 October 2015
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 19 (5) , 435-440
Accuracy of the Spot and Plusoptix photoscreeners for detection of astigmatism
- Open Access
- 1 August 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (8) , 5420-5430
Accommodation in Astigmatic Children During Visual Task Performance
Purpose. To determine the accuracy and stability of accommodation in uncorrected children during visual task performance. Methods. Subjects were second- to seventh-grade children from a highly astigmatic population. Measurements of noncycloplegic right eye spherical equivalent (Mnc) were obtained while uncorrected subjects performed three visual tasks at near (40 cm) and distance (2 m). Tasks included reading sentences with stimulus letter size near acuity threshold and an age-appropriate letter size (high task demands) and viewing a video (low task demand). Repeated measures ANOVA assessed the influence of astigmatism, task demand, and accommodative demand on accuracy (mean Mnc) and variability (mean SD of Mnc) of accommodation. Results. For near and distance analyses, respectively, sample size was 321 and 247, mean age was 10.37 (SD 1.77) and 10.30 (SD 1.74) years, mean cycloplegic M was 0.48 (SD 1.10) and 0.79 diopters (D) (SD 1.00), and mean astigmatism was 0.99 (SD 1.15) and 0.75 D (SD 0.96). Poor accommodative accuracy was associated with high astigmatism, low task demand (video viewing), and high accommodative demand. The negative effect of accommodative demand on accuracy increased with increasing astigmatism, with the poorest accommodative accuracy observed in high astigmats (≥3.00 D) with high accommodative demand/high hyperopia (1.53 D and 2.05 D of underaccommodation for near and distant stimuli, respectively). Accommodative variability was greatest in high astigmats and was uniformly high across task condition. No/low and moderate astigmats showed higher variability for the video task than the reading tasks. Conclusions. Accuracy of accommodation is reduced in uncorrected children with high astigmatism and high accommodative demand/high hyperopia, but improves with increased visual task demand (reading). High astigmats showed the greatest variability in accommodation.
- 1 August 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (8) , 5420-5430
Open AccessAccommodation in Astigmatic Children During Visual Task Performance
Purpose. To determine the accuracy and stability of accommodation in uncorrected children during visual task performance. Methods. Subjects were second- to seventh-grade children from a highly astigmatic population. Measurements of noncycloplegic right eye spherical equivalent (Mnc) were obtained while uncorrected subjects performed three visual tasks at near (40 cm) and distance (2 m). Tasks included reading sentences with stimulus letter size near acuity threshold and an age-appropriate letter size (high task demands) and viewing a video (low task demand). Repeated measures ANOVA assessed the influence of astigmatism, task demand, and accommodative demand on accuracy (mean Mnc) and variability (mean SD of Mnc) of accommodation. Results. For near and distance analyses, respectively, sample size was 321 and 247, mean age was 10.37 (SD 1.77) and 10.30 (SD 1.74) years, mean cycloplegic M was 0.48 (SD 1.10) and 0.79 diopters (D) (SD 1.00), and mean astigmatism was 0.99 (SD 1.15) and 0.75 D (SD 0.96). Poor accommodative accuracy was associated with high astigmatism, low task demand (video viewing), and high accommodative demand. The negative effect of accommodative demand on accuracy increased with increasing astigmatism, with the poorest accommodative accuracy observed in high astigmats (≥3.00 D) with high accommodative demand/high hyperopia (1.53 D and 2.05 D of underaccommodation for near and distant stimuli, respectively). Accommodative variability was greatest in high astigmats and was uniformly high across task condition. No/low and moderate astigmats showed higher variability for the video task than the reading tasks. Conclusions. Accuracy of accommodation is reduced in uncorrected children with high astigmatism and high accommodative demand/high hyperopia, but improves with increased visual task demand (reading). High astigmats showed the greatest variability in accommodation.
- 1 June 2014
- Published by Wiley in Optometry and Vision Science
- Vol. 91 (6) , 624-633
Rasch Analysis of the Student Refractive Error and Eyeglass Questionnaire
Purpose: To evaluate and refine a newly developed instrument, the Student Refractive Error and Eyeglasses Questionnaire (SREEQ), designed to measure the impact of uncorrected and corrected refractive error on vision‐related quality of life (VRQoL) in school‐aged children. Methods: A 38‐statement instrument consisting of two parts was developed: part A relates to perceptions regarding uncorrected vision and part B relates to perceptions regarding corrected vision and includes other statements regarding VRQoL with spectacle correction. The SREEQ was administered to 200 Native American 6th‐ through 12th‐grade students known to have previously worn and who currently require eyeglasses. Rasch analysis was conducted to evaluate the functioning of the SREEQ. Statements on parts A and B were analyzed to examine the dimensionality and constructs of the questionnaire, how well the items functioned, and the appropriateness of the response scale used. Results: Rasch analysis suggested two items be eliminated and the measurement scale for matching items be reduced from a four‐point response scale to a three‐point response scale. With these modifications, categorical data were converted to interval‐level data to conduct an item and person analysis. A shortened version of the SREEQ was constructed with these modifications, the SREEQ‐R, which included the statements that were able to capture changes in VRQoL associated with spectacle wear for those with significant refractive error in our study population. Conclusions: Although part B of the SREEQ appears to have a less‐than‐optimal reliability to assess the impact of spectacle correction on VRQoL in our student population, it is able to detect statistically significant differences from pretest to posttest on both the group and individual levels to show that the instrument can assess the impact that glasses have on VRQoL. Further modifications to the questionnaire, such as those included in the SREEQ‐R, could enhance its functionality.
- 1 June 2014
- Published by Wiley in Optometry and Vision Science
- Vol. 91 (6) , 624-633
Rasch Analysis of the Student Refractive Error and Eyeglass Questionnaire
Purpose: To evaluate and refine a newly developed instrument, the Student Refractive Error and Eyeglasses Questionnaire (SREEQ), designed to measure the impact of uncorrected and corrected refractive error on vision‐related quality of life (VRQoL) in school‐aged children. Methods: A 38‐statement instrument consisting of two parts was developed: part A relates to perceptions regarding uncorrected vision and part B relates to perceptions regarding corrected vision and includes other statements regarding VRQoL with spectacle correction. The SREEQ was administered to 200 Native American 6th‐ through 12th‐grade students known to have previously worn and who currently require eyeglasses. Rasch analysis was conducted to evaluate the functioning of the SREEQ. Statements on parts A and B were analyzed to examine the dimensionality and constructs of the questionnaire, how well the items functioned, and the appropriateness of the response scale used. Results: Rasch analysis suggested two items be eliminated and the measurement scale for matching items be reduced from a four‐point response scale to a three‐point response scale. With these modifications, categorical data were converted to interval‐level data to conduct an item and person analysis. A shortened version of the SREEQ was constructed with these modifications, the SREEQ‐R, which included the statements that were able to capture changes in VRQoL associated with spectacle wear for those with significant refractive error in our study population. Conclusions: Although part B of the SREEQ appears to have a less‐than‐optimal reliability to assess the impact of spectacle correction on VRQoL in our student population, it is able to detect statistically significant differences from pretest to posttest on both the group and individual levels to show that the instrument can assess the impact that glasses have on VRQoL. Further modifications to the questionnaire, such as those included in the SREEQ‐R, could enhance its functionality.
- 1 June 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (6) , 892-900
Predictors of Adequate Correction Following Vision Screening Failure
Purpose.: To determine whether compliance with referral 1 year after vision screening failure was associated with care model, demographic, or ocular factors. Methods.: Data were analyzed from 798 children in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error Study with habitual logMAR visual acuity (VA) ≥0.26 (20/40 + 2 or worse) in either eye due to uncorrected or undercorrected refractive error and who returned the following year. The parents of 492 children failing in TX and CA were sent letters indicating the need for a complete vision examination (screening model), while 306 children seen primarily in AZ and AL received a free complete examination and eyeglasses if needed (complete care model). Presenting to follow‐up with adequate correction (logMAR <0.26) in each eye was considered compliant. Logistic regression models for compliance were fit to assess whether care model, ethnicity, sex, age, uncorrected logMAR in the better eye, or parental income, education, or myopia were predictors. Results.: Overall compliance was 28%. Age [p = 0.01, odds ratio (OR) = 1.12] and uncorrected logMAR (p < 0.001, OR = 1.13) were associated with compliance but care model, ethnicity, and sex were not. Among the 447 children for whom data on parental factors were available, 27% were compliant. In this model, age, ethnicity, sex, parental income, parental education, and parental myopia were not associated with compliance, but uncorrected logMAR (p = 0.005; OR = 1.13) was predictive. An interaction between unaided VA and care model predicted improved compliance with poorer unaided VA in the complete care model. Conclusions.: Expensive complete care screening programs may not improve compliance over typical notification and referral screening protocols in school‐aged children, unless unaided VA is worse than the common 20/40 referral criteria. Unaided VA had less impact on predicted compliance in the screening‐only protocol.
- 1 June 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (6) , 892-900
Predictors of Adequate Correction Following Vision Screening Failure
Purpose.: To determine whether compliance with referral 1 year after vision screening failure was associated with care model, demographic, or ocular factors. Methods.: Data were analyzed from 798 children in the Collaborative Longitudinal Evaluation of Ethnicity and Refractive Error Study with habitual logMAR visual acuity (VA) ≥0.26 (20/40 + 2 or worse) in either eye due to uncorrected or undercorrected refractive error and who returned the following year. The parents of 492 children failing in TX and CA were sent letters indicating the need for a complete vision examination (screening model), while 306 children seen primarily in AZ and AL received a free complete examination and eyeglasses if needed (complete care model). Presenting to follow‐up with adequate correction (logMAR <0.26) in each eye was considered compliant. Logistic regression models for compliance were fit to assess whether care model, ethnicity, sex, age, uncorrected logMAR in the better eye, or parental income, education, or myopia were predictors. Results.: Overall compliance was 28%. Age [p = 0.01, odds ratio (OR) = 1.12] and uncorrected logMAR (p < 0.001, OR = 1.13) were associated with compliance but care model, ethnicity, and sex were not. Among the 447 children for whom data on parental factors were available, 27% were compliant. In this model, age, ethnicity, sex, parental income, parental education, and parental myopia were not associated with compliance, but uncorrected logMAR (p = 0.005; OR = 1.13) was predictive. An interaction between unaided VA and care model predicted improved compliance with poorer unaided VA in the complete care model. Conclusions.: Expensive complete care screening programs may not improve compliance over typical notification and referral screening protocols in school‐aged children, unless unaided VA is worse than the common 20/40 referral criteria. Unaided VA had less impact on predicted compliance in the screening‐only protocol.
- 1 January 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (1) , 19-26
Spectacle Wear in Children Given Spectacles Through a School‐Based Program
Purpose.: To investigate factors associated with spectacle wear in a group of primarily Native‐American children provided spectacles free of charge through a school‐based vision program. Methods.: Spectacle wear was studied in 247 participants provided two pairs of spectacles the previous year. Univariate and multivariate logistic regression models assessed whether gender, race, parental education levels, family income, uncorrected distance visual acuity, refractive error, or the children's attitudes and beliefs about their vision and spectacles were associated with spectacle wear. Results.: Two thirds of the participants (165/247) were not wearing their spectacles at their annual examination. The most common reasons given for non‐wear were lost (44.9%) or broken (35.3%) spectacles. A 1 diopter increase in myopic spherical equivalent was associated with more than a twofold increase in the odds of wearing spectacles [odds ratio (OR) = 2.5, 95% confidence interval (CI) = 1.7 to 3.7]. Among non‐myopic participants, increasing amounts of astigmatism in the better‐ and worse‐seeing eye were associated with an increased likelihood of spectacle wear (p ≤ 0.02). In multivariate analysis, only poorer uncorrected acuity in the better‐seeing eye (p < 0.001) and shorter acceptance time (p = 0.007) were found to be significantly associated with spectacle wear. For each line of poorer uncorrected acuity in the better‐seeing eye, the likelihood that the participant was wearing spectacles increased by 60% (adjusted odds ratio = 1.6; 95% CI = 1.4 to 1.8). Not surprisingly, participants who reported never getting used to their spectacles were less likely to be wearing spectacles than those who reported getting used to wearing glasses in a few days (adjusted OR = 5.7, 95% CI = 1.9 to 17.5). Conclusions.: Despite being provided with two pairs of spectacles, loss and breakage were the most commonly reported reasons for not wearing spectacles. The best predictive factor for determining whether participants were wearing spectacles was their uncorrected acuity.
- 1 January 2012
- Published by Wiley in Optometry and Vision Science
- Vol. 89 (1) , 19-26
Spectacle Wear in Children Given Spectacles Through a School‐Based Program
Purpose.: To investigate factors associated with spectacle wear in a group of primarily Native‐American children provided spectacles free of charge through a school‐based vision program. Methods.: Spectacle wear was studied in 247 participants provided two pairs of spectacles the previous year. Univariate and multivariate logistic regression models assessed whether gender, race, parental education levels, family income, uncorrected distance visual acuity, refractive error, or the children's attitudes and beliefs about their vision and spectacles were associated with spectacle wear. Results.: Two thirds of the participants (165/247) were not wearing their spectacles at their annual examination. The most common reasons given for non‐wear were lost (44.9%) or broken (35.3%) spectacles. A 1 diopter increase in myopic spherical equivalent was associated with more than a twofold increase in the odds of wearing spectacles [odds ratio (OR) = 2.5, 95% confidence interval (CI) = 1.7 to 3.7]. Among non‐myopic participants, increasing amounts of astigmatism in the better‐ and worse‐seeing eye were associated with an increased likelihood of spectacle wear (p ≤ 0.02). In multivariate analysis, only poorer uncorrected acuity in the better‐seeing eye (p < 0.001) and shorter acceptance time (p = 0.007) were found to be significantly associated with spectacle wear. For each line of poorer uncorrected acuity in the better‐seeing eye, the likelihood that the participant was wearing spectacles increased by 60% (adjusted odds ratio = 1.6; 95% CI = 1.4 to 1.8). Not surprisingly, participants who reported never getting used to their spectacles were less likely to be wearing spectacles than those who reported getting used to wearing glasses in a few days (adjusted OR = 5.7, 95% CI = 1.9 to 17.5). Conclusions.: Despite being provided with two pairs of spectacles, loss and breakage were the most commonly reported reasons for not wearing spectacles. The best predictive factor for determining whether participants were wearing spectacles was their uncorrected acuity.