Bo-Seung Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bo-Seung Kim has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Hong Hee Yoo
Hanyang University
1 shared publication - Moon Jeong Kang
School of Mechanical Engineering, Hanyang University, Wangshimni-ro 222, Seongdong-gu, Seoul 04763, South Korea
1 shared publication - Sejin Hwang
Department of Anatomy and Cell Biology, College of Medicine, Hanyang University, Seoul, Korea
1 shared publication
Latest Publications
- 18 August 2018
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 61 (1) , 25-31
Experimentally derived viscoelastic properties of human skin and muscle in vitro
Measurement of the mechanical properties of human skin in vivo is challenging. Moreover, those with regard to excitation frequency have been rarely reported thus far. In this study, a vibration-based experimental method was employed to measure the viscoelastic properties with regard to the excitation frequency. Pieces of human skin and skeletal muscle excised from cadavers immediately post mortem were stored in a sealed container. As the experiment began, they were removed from the container and used to measure the viscoelastic properties as time elapsed. Young's moduli of the samples of human skin tissue that were immediately removed from the container were found to be similar to those obtained with in-vivo indentation methods. They were also found to be approximately one-third of those of human skeletal muscles. The viscoelastic properties of human skin were found to remain almost constant within the frequency range up to 120 Hz and are similar to those of porcine tissue. Young's moduli of the human skin and skeletal muscle were also found to reach the maximum values approximately five days post mortem. However, the loss factor of the human skin did not vary significantly as time elapses.
- 18 August 2018
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 61 (1) , 25-31
Experimentally derived viscoelastic properties of human skin and muscle in vitro
Measurement of the mechanical properties of human skin in vivo is challenging. Moreover, those with regard to excitation frequency have been rarely reported thus far. In this study, a vibration-based experimental method was employed to measure the viscoelastic properties with regard to the excitation frequency. Pieces of human skin and skeletal muscle excised from cadavers immediately post mortem were stored in a sealed container. As the experiment began, they were removed from the container and used to measure the viscoelastic properties as time elapsed. Young's moduli of the samples of human skin tissue that were immediately removed from the container were found to be similar to those obtained with in-vivo indentation methods. They were also found to be approximately one-third of those of human skeletal muscles. The viscoelastic properties of human skin were found to remain almost constant within the frequency range up to 120 Hz and are similar to those of porcine tissue. Young's moduli of the human skin and skeletal muscle were also found to reach the maximum values approximately five days post mortem. However, the loss factor of the human skin did not vary significantly as time elapses.