Heinrich Wolf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Heinrich Wolf has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Johannes Weber
Fraunhofer Institut für Elektronische Mikrosysteme Festkörpertechnologien EMFT Munich Germany
2 shared publications - Petr Bělský
New Technologies—Research Centre (NTC) University of West Bohemia Univerzitní 8 30100 Pilsen Czech Republic
2 shared publications R. Streiter
Fraunhofer ENAS, Technologie-Campus 3, 09126 Chemnitz, Germany
2 shared publications- Rita Fung
Cisco Systems, San Jose, CA, USA
2 shared publications T. Gessner
Chemnitz University of Technology, Center for Microtechnologies, Reichenhainer Str. 70, 09126 Chemnitz, Germany and Fraunhofer ENAS, Technologie-Campus 3, 09126 Chemnitz, Germany
2 shared publicationsHorst A. Gieser
Circuits & Systems, Fraunhofer EMFT, Munich, Germany
1 shared publication
Latest Publications
- 1 December 2020
- Published by Elsevier in Microelectronics Reliability
- Vol. 115, 113977
Discharge current analysis with charged connector pins
- 1 December 2020
- Published by Elsevier in Microelectronics Reliability
- Vol. 115, 113977
Discharge current analysis with charged connector pins
- 7 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 19 (4) , 591-601
Stress Current Slew Rate Sensitivity of an Ultra-High-Speed Interface IC
This study analyzes the Electrostatic Discharge (ESD) susceptibility of a 28 nm high-speed CMOS Integrated Circuit (IC) for network applications (25 Gbps), showing a non-negligible failure rate in manufacturing after having passed Charged Device Model (CDM) qualification testing. A detailed inspection of each process step identified the press-fit assembly of charged through-hole connectors to be the root cause for ultra-fast discharges through the Printed Circuit Board (PCB) traces into the high-speed RF interface. Extended CDM tests of the high-speed ICs displayed a wide overlap of pass and fail not allowing for a clear conclusion regarding the CDM robustness. Only the single digit ps-resolution and precision of the highly reproducible test method Capacitively Coupled Transmission Line Pulsing (CC-TLP) allowed a conclusive sharp pass/fail transition at a certain peak current level. In combination with a 33/63 GHz single shot oscilloscope, it eventually identified the stress current slew rate to have a direct influence on the failure threshold, explaining the non-conclusive failure distribution of CDM. For this result, we had to increase the bandwidth of the CC-TLP setup, challenge the limits of today's metrology and test setups, and implement post measurement embedding/de-embedding techniques. By pushing the frontiers of today's ESD testing in the CDM domain, the outcome of this study should contribute to future standardization of CDM and CC-TLP.
- 7 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 19 (4) , 591-601
Stress Current Slew Rate Sensitivity of an Ultra-High-Speed Interface IC
This study analyzes the Electrostatic Discharge (ESD) susceptibility of a 28 nm high-speed CMOS Integrated Circuit (IC) for network applications (25 Gbps), showing a non-negligible failure rate in manufacturing after having passed Charged Device Model (CDM) qualification testing. A detailed inspection of each process step identified the press-fit assembly of charged through-hole connectors to be the root cause for ultra-fast discharges through the Printed Circuit Board (PCB) traces into the high-speed RF interface. Extended CDM tests of the high-speed ICs displayed a wide overlap of pass and fail not allowing for a clear conclusion regarding the CDM robustness. Only the single digit ps-resolution and precision of the highly reproducible test method Capacitively Coupled Transmission Line Pulsing (CC-TLP) allowed a conclusive sharp pass/fail transition at a certain peak current level. In combination with a 33/63 GHz single shot oscilloscope, it eventually identified the stress current slew rate to have a direct influence on the failure threshold, explaining the non-conclusive failure distribution of CDM. For this result, we had to increase the bandwidth of the CC-TLP setup, challenge the limits of today's metrology and test setups, and implement post measurement embedding/de-embedding techniques. By pushing the frontiers of today's ESD testing in the CDM domain, the outcome of this study should contribute to future standardization of CDM and CC-TLP.
- 1 April 2012
- Published by Elsevier in Microelectronic Engineering
- Vol. 92, 107-110
Modeling of TDDB in advanced Cu interconnect systems under BTS conditions
- 1 April 2012
- Published by Elsevier in Microelectronic Engineering
- Vol. 92, 107-110
Modeling of TDDB in advanced Cu interconnect systems under BTS conditions
- 1 October 2010
- Published by Elsevier in Microelectronic Engineering
- Vol. 87 (10) , 1907-1913
Simulation of TaN deposition by Reactive PVD
- 1 October 2010
- Published by Elsevier in Microelectronic Engineering
- Vol. 87 (10) , 1907-1913
Simulation of TaN deposition by Reactive PVD