Andreas Logothetis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andreas Logothetis has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
A Dimitriadis
1 shared publicationE Pantelis
1 shared publicationE Zoros
1 shared publicationEfi Koutsouveli
Medical Physics Department, Hygeia Hospital, Athens, Greece
1 shared publicationEleftherios P Pappas
Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Athens, Greece
1 shared publication- Eleftherios P. Pappas
Medical Physics Laboratory, Medical School National and Kapodistrian University of Athens Athens Greece
1 shared publication
Latest Publications
- Open Access
- 5 February 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (3) , 32-44
Dosimetric impact of rotational errors on the quality of VMAT‐SRS for multiple brain metastases: Comparison between single‐ and two‐isocenter treatment planning techniques
Purpose: In the absence of a 6D couch and/or assuming considerable intrafractional patient motion, rotational errors could affect target coverage and OAR‐sparing especially in multiple metastases VMAT‐SRS cranial cases, which often involve the concurrent irradiation of off‐axis targets. This work aims to study the dosimetric impact of rotational errors in such applications, under a comparative perspective between the single‐ and two‐isocenter treatment techniques.Methods: Ten patients (36 metastases) were included in this study. Challenging cases were only considered, with several targets lying in close proximity to OARs. Two multiarc VMAT plans per patient were prepared, involving one and two isocenters, serving as the reference plans. Different degrees of angular offsets at various orientations were introduced, simulating rotational errors. Resulting dose distributions were evaluated and compared using commonly employed dose‐volume and plan quality indices.Results: For single‐isocenter plans and 1⁰ rotations, plan quality indices, such as coverage, conformity index and D95%, deteriorated significantly (>5%) for distant targets from the isocenter (at> 4–6 cm). Contrarily, for two‐isocenter plans, target distances to nearest isocenter were always shorter (≤4 cm), and, consequently, 1⁰ errors were well‐tolerated. In the most extreme case considered (2⁰ around all axes) conformity index deteriorated by on‐average 7.2%/cm of distance to isocenter, if one isocenter is used, and 2.6%/cm, for plans involving two isocenters. The effect is, however, strongly associated with target volume. Regarding OARs, for single‐isocenter plans, significant increase (up to 63%) in Dmax and D0.02cc values was observed for any angle of rotation. Plans that could be considered clinically unacceptable were obtained even for the smallest angle considered, although rarer for the two‐isocenter planning approach.Conclusion: Limiting the lesion‐to‐isocenter distance to ≤4 cm by introducing additional isocenter(s) appears to partly mitigate severe target underdosage, especially for smaller target sizes. If OAR‐sparing is also a concern, more stringent rotational error tolerances apply.
- 5 February 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (3) , 32-44
Open AccessDosimetric impact of rotational errors on the quality of VMAT‐SRS for multiple brain metastases: Comparison between single‐ and two‐isocenter treatment planning techniques
Purpose: In the absence of a 6D couch and/or assuming considerable intrafractional patient motion, rotational errors could affect target coverage and OAR‐sparing especially in multiple metastases VMAT‐SRS cranial cases, which often involve the concurrent irradiation of off‐axis targets. This work aims to study the dosimetric impact of rotational errors in such applications, under a comparative perspective between the single‐ and two‐isocenter treatment techniques.Methods: Ten patients (36 metastases) were included in this study. Challenging cases were only considered, with several targets lying in close proximity to OARs. Two multiarc VMAT plans per patient were prepared, involving one and two isocenters, serving as the reference plans. Different degrees of angular offsets at various orientations were introduced, simulating rotational errors. Resulting dose distributions were evaluated and compared using commonly employed dose‐volume and plan quality indices.Results: For single‐isocenter plans and 1⁰ rotations, plan quality indices, such as coverage, conformity index and D95%, deteriorated significantly (>5%) for distant targets from the isocenter (at> 4–6 cm). Contrarily, for two‐isocenter plans, target distances to nearest isocenter were always shorter (≤4 cm), and, consequently, 1⁰ errors were well‐tolerated. In the most extreme case considered (2⁰ around all axes) conformity index deteriorated by on‐average 7.2%/cm of distance to isocenter, if one isocenter is used, and 2.6%/cm, for plans involving two isocenters. The effect is, however, strongly associated with target volume. Regarding OARs, for single‐isocenter plans, significant increase (up to 63%) in Dmax and D0.02cc values was observed for any angle of rotation. Plans that could be considered clinically unacceptable were obtained even for the smallest angle considered, although rarer for the two‐isocenter planning approach.Conclusion: Limiting the lesion‐to‐isocenter distance to ≤4 cm by introducing additional isocenter(s) appears to partly mitigate severe target underdosage, especially for smaller target sizes. If OAR‐sparing is also a concern, more stringent rotational error tolerances apply.
- 1 February 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (4) , 045011
Dosimetric evaluation of the Leksell GammaPlan ™ Convolution dose calculation algorithm
The dosimetric accuracy of the Leksell GammaPlan Convolution calculation algorithm was evaluated through comparison with corresponding Monte Carlo (MC) dosimetric results. MC simulations were based on generated sector phase space files for the 4 mm, 8 mm and 16 mm collimator sizes, using a previous comprehensive Gamma Knife Perfexion ™ source model and validated using film dosimetry. Test cases were designed for the evaluation of the Convolution algorithm involving irradiation of homogeneous and inhomogeneous phantom geometries mimicking clinical cases, with radiation fields created using one sector (single sector), all sectors with the same (single shot) or different (composite shot) collimator sizes. Dose calculations using the Convolution algorithm were found to be in excellent agreement (gamma pass rate greater than 98%, applying 1%/1 mm local dose difference and distance agreement criteria), with corresponding MC calculations, indicating the accuracy of the Convolution algorithm in homogeneous and heterogeneous model geometries. While of minor clinical importance, large deviations were observed for the voxels laying inside air media. The calculated beam on times using the Convolution algorithm were found to increase (up to 7%) relative to the TMR 10 algorithm currently used in clinical practice, especially in a test case mimicking a brain metastasis close to the skull, in excellent agreement with corresponding MC calculations.
- 1 February 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (4) , 045011
Dosimetric evaluation of the Leksell GammaPlan ™ Convolution dose calculation algorithm
The dosimetric accuracy of the Leksell GammaPlan Convolution calculation algorithm was evaluated through comparison with corresponding Monte Carlo (MC) dosimetric results. MC simulations were based on generated sector phase space files for the 4 mm, 8 mm and 16 mm collimator sizes, using a previous comprehensive Gamma Knife Perfexion ™ source model and validated using film dosimetry. Test cases were designed for the evaluation of the Convolution algorithm involving irradiation of homogeneous and inhomogeneous phantom geometries mimicking clinical cases, with radiation fields created using one sector (single sector), all sectors with the same (single shot) or different (composite shot) collimator sizes. Dose calculations using the Convolution algorithm were found to be in excellent agreement (gamma pass rate greater than 98%, applying 1%/1 mm local dose difference and distance agreement criteria), with corresponding MC calculations, indicating the accuracy of the Convolution algorithm in homogeneous and heterogeneous model geometries. While of minor clinical importance, large deviations were observed for the voxels laying inside air media. The calculated beam on times using the Convolution algorithm were found to increase (up to 7%) relative to the TMR 10 algorithm currently used in clinical practice, especially in a test case mimicking a brain metastasis close to the skull, in excellent agreement with corresponding MC calculations.