Jiří Spilka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiří Spilka has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Michal Huptych
Czech Technical University in Prague
3 shared publicationsVáclav Chudáček
Czech Technical University in Prague
3 shared publications- Lenka Lhotska
Czech Technical University in Prague
2 shared publications Lukáš Hruban
Department of Gynecology and Obstetrics, Masaryk University Hospital, Brno, Czech Republic
2 shared publicationsMiroslav Burša
Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic
2 shared publicationsMuriel Doret
Femme-Mère-Enfant Hospital
2 shared publications
Latest Publications
- 17 September 2016
- Published by Springer Nature
- p. 1199-1204
Intrapartum Fetal Heart Rate Classification: Cross-Database Evaluation
- 17 September 2016
- Published by Springer Nature
- p. 1199-1204
Intrapartum Fetal Heart Rate Classification: Cross-Database Evaluation
- 24 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 21 (3) , 664-671
Sparse Support Vector Machine for Intrapartum Fetal Heart Rate Classification
Fetal heart rate (FHR) monitoring is routinely used in clinical practice to help obstetricians assess fetal health status during delivery. However, early detection of fetal acidosis that allows relevant decisions for operative delivery remains a challenging task, receiving considerable attention. This contribution promotes sparse support vector machine classification that permits to select a small number of relevant features and to achieve efficient fetal acidosis detection. A comprehensive set of features is used for FHR description, including enhanced and computerized clinical features, frequency domain, and scaling and multifractal features, all computed on a large (1288 subjects) and well-documented database. The individual performance obtained for each feature independently is discussed first. Then, it is shown that the automatic selection of a sparse subset of features achieves satisfactory classification performance (sensitivity 0.73 and specificity 0.75, outperforming clinical practice). The subset of selected features (average depth of decelerations MAD dtrd , baseline level β 0 , and variability H) receives simple interpretation in clinical practice. Intrapartum fetal acidosis detection is improved in several respects: A comprehensive set of features combining clinical, spectral, and scale-free dynamics is used; an original multivariate classification targeting both sparse feature selection and high performance is devised; state-of-the-art performance is obtained on a much larger database than that generally studied with description of common pitfalls in supervised classification performance assessments.
- 24 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 21 (3) , 664-671
Sparse Support Vector Machine for Intrapartum Fetal Heart Rate Classification
Fetal heart rate (FHR) monitoring is routinely used in clinical practice to help obstetricians assess fetal health status during delivery. However, early detection of fetal acidosis that allows relevant decisions for operative delivery remains a challenging task, receiving considerable attention. This contribution promotes sparse support vector machine classification that permits to select a small number of relevant features and to achieve efficient fetal acidosis detection. A comprehensive set of features is used for FHR description, including enhanced and computerized clinical features, frequency domain, and scaling and multifractal features, all computed on a large (1288 subjects) and well-documented database. The individual performance obtained for each feature independently is discussed first. Then, it is shown that the automatic selection of a sparse subset of features achieves satisfactory classification performance (sensitivity 0.73 and specificity 0.75, outperforming clinical practice). The subset of selected features (average depth of decelerations MAD dtrd , baseline level β 0 , and variability H) receives simple interpretation in clinical practice. Intrapartum fetal acidosis detection is improved in several respects: A comprehensive set of features combining clinical, spectral, and scale-free dynamics is used; an original multivariate classification targeting both sparse feature selection and high performance is devised; state-of-the-art performance is obtained on a much larger database than that generally studied with description of common pitfalls in supervised classification performance assessments.
- 26 May 2015
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 21 (4) , 694-702
Agreement on intrapartum cardiotocogram recordings between expert obstetricians
Rationale, aims and objectives: To evaluate obstetricians' inter‐ and intra‐observer agreement on intrapartum cardiotocogram (CTG) recordings and to examine obstetricians' evaluations with respect to umbilical artery pH and base deficit.Methods: Nine experienced obstetricians annotated 634 intrapartum CTG recordings. The evaluation of each recording was divided into four steps: evaluation of two 30‐minute windows in the first stage of labour, evaluation of one window in the second stage of labour and labour outcome prediction. The complete set of evaluations used for this experiment is available online. The inter‐ and intra‐observer agreement was evaluated using proportion of agreement and kappa coefficient. Clinicians' sensitivity and specificity was computed with respect to umbilical artery pH, base deficit and to Apgar score at the fifth minute.Results: The overall proportion of agreement between clinicians reached 48% with 95% confidence intervals (CI) (CI: 47–50). Regarding the different classes, proportion of agreement ranged from 57% (CI: 54–60) for normal to 41% (CI: 36–46) for pathological class. The sensitivity of clinicians' majority vote to objective outcome was 39% (CI: 16–63) for the umbilical artery base deficit and 27% (CI: 16–42) for pH. The specificity was 89% (CI: 86–92) for both types of objective outcome.Conclusions: The reported inter‐/intra‐observer variability is large and this holds irrespective of clinicians' experience or work place. The results support the need of modernized guidelines for CTG evaluation and/or objectivization and repeatability by introduction of a computerized approach that could standardize the process of CTG evaluation within the delivery ward.
- 26 May 2015
- Published by Wiley in Journal of Evaluation in Clinical Practice
- Vol. 21 (4) , 694-702
Agreement on intrapartum cardiotocogram recordings between expert obstetricians
Rationale, aims and objectives: To evaluate obstetricians' inter‐ and intra‐observer agreement on intrapartum cardiotocogram (CTG) recordings and to examine obstetricians' evaluations with respect to umbilical artery pH and base deficit.Methods: Nine experienced obstetricians annotated 634 intrapartum CTG recordings. The evaluation of each recording was divided into four steps: evaluation of two 30‐minute windows in the first stage of labour, evaluation of one window in the second stage of labour and labour outcome prediction. The complete set of evaluations used for this experiment is available online. The inter‐ and intra‐observer agreement was evaluated using proportion of agreement and kappa coefficient. Clinicians' sensitivity and specificity was computed with respect to umbilical artery pH, base deficit and to Apgar score at the fifth minute.Results: The overall proportion of agreement between clinicians reached 48% with 95% confidence intervals (CI) (CI: 47–50). Regarding the different classes, proportion of agreement ranged from 57% (CI: 54–60) for normal to 41% (CI: 36–46) for pathological class. The sensitivity of clinicians' majority vote to objective outcome was 39% (CI: 16–63) for the umbilical artery base deficit and 27% (CI: 16–42) for pH. The specificity was 89% (CI: 86–92) for both types of objective outcome.Conclusions: The reported inter‐/intra‐observer variability is large and this holds irrespective of clinicians' experience or work place. The results support the need of modernized guidelines for CTG evaluation and/or objectivization and repeatability by introduction of a computerized approach that could standardize the process of CTG evaluation within the delivery ward.
- 1 October 2014
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 51, 72-79
Analysis of obstetricians’ decision making on CTG recordings
- 1 October 2014
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 51, 72-79
Analysis of obstetricians’ decision making on CTG recordings