Ana Carolina Do Amaral Henrique de Souza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana Carolina Do Amaral Henrique de Souza has a total of 214 co-authors. Here are the top co-authors by number of shared publications:
- Thais R. Peclat
Metabolism and Molecular Nutrition Laboratory, Kogod Center on Aging, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic College of Medicine, Rochester, USA
4 shared publications - Andrea De Lorenzo
Coordenação de Ensino E Pesquisa, Instituto Nacional de Cardiologia, Rio de Janeiro, Brazil
2 shared publications Jade Iwasaka-Neder
2 shared publications- Jon Hainer
Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School , Boston, MA
2 shared publications Ron Blankstein
Cardiovascular Imaging Program, Departments of Medicine and Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
2 shared publications- Ronaldo de Souza Leão Lima
Universidade Federal do Rio de Janeiro
2 shared publications
Latest Publications
- 25 February 2025
- Published by Sociedade Brasileira de Cardiologia in International Journal of Cardiovascular Sciences
- Vol. 38
Myocardial Ischemia and the Emerging Role of Coronary Flow Reserve Quantification
Recent years have seen remarkable advances in nuclear cardiology. The introduction of cardiac positron emission tomography (PET) and the development of cadmium-zinc-telluride (CZT) imaging systems have significantly improved diagnostic accuracy, clinical decision-making, and ultimately outcomes for patients with coronary artery disease (CAD). In this issue, Giubbini and Milan review key concepts related to myocardial ischemia and explore the emerging importance of quantifying coronary flow reserve (CFR) in patients with known or suspected CAD. PET imaging has become a preeminent modality
- 25 February 2025
- Published by Sociedade Brasileira de Cardiologia in International Journal of Cardiovascular Sciences
- Vol. 38
Myocardial Ischemia and the Emerging Role of Coronary Flow Reserve Quantification
Recent years have seen remarkable advances in nuclear cardiology. The introduction of cardiac positron emission tomography (PET) and the development of cadmium-zinc-telluride (CZT) imaging systems have significantly improved diagnostic accuracy, clinical decision-making, and ultimately outcomes for patients with coronary artery disease (CAD). In this issue, Giubbini and Milan review key concepts related to myocardial ischemia and explore the emerging importance of quantifying coronary flow reserve (CFR) in patients with known or suspected CAD. PET imaging has become a preeminent modality
- 31 January 2025
- Published by Elsevier
- p. 347-350
Data management
- 31 January 2025
- Published by Elsevier
Contributors
- 8 June 2022
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 15 (6) , e013987
Accuracy and Reproducibility of Myocardial Blood Flow Quantification by Single Photon Emission Computed Tomography Imaging in Patients With Known or Suspected Coronary Artery Disease
Background: Single photon emission computed tomography (SPECT) has limited ability to identify multivessel and microvascular coronary artery disease. Gamma cameras with cadmium zinc telluride detectors allow the quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR). However, evidence of its accuracy is limited, and of its reproducibility is lacking. We aimed to validate 99m Tc-sestamibi SPECT MBF and MFR using standard and spline-fitted reconstruction algorithms compared with 13 N-ammonia positron emission tomography in a cohort of patients with known or suspected coronary artery disease and to evaluate the reproducibility of this technique. Methods: Accuracy was assessed in 34 participants who underwent dynamic 99m Tc-sestamibi SPECT and 13 N-ammonia positron emission tomography and reproducibility in 14 participants who underwent 2 99m Tc-sestamibi SPECT studies, all within 2 weeks. A rest/pharmacological stress single-day SPECT protocol was performed. SPECT images were reconstructed using a standard ordered subset expectation maximization (OSEM) algorithm with (N=21) and without (N=30) application of spline fitting. SPECT MBF was quantified using a net retention kinetic model‚ and MFR was derived as the stress/rest MBF ratio. Results: SPECT global MBF with splines showed good correlation with 13 N-ammonia positron emission tomography (r=0.81, P P P P =0.07, for MBF and MFR, respectively). Reproducibility of global MBF estimates with splines in paired SPECT scans was good (r=0.77, P P 0.05 for all). Conclusions: MBF and MFR quantification using 99m Tc-sestamibi cadmium zinc telluride SPECT with spatiotemporal spline fitting improved the correlation with 13 N-ammonia positron emission tomography flow estimates and test/retest reproducibility. The use of splines may represent an important step toward the standardization of SPECT flow estimation.
- 8 June 2022
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 15 (6) , e013987
Accuracy and Reproducibility of Myocardial Blood Flow Quantification by Single Photon Emission Computed Tomography Imaging in Patients With Known or Suspected Coronary Artery Disease
Background: Single photon emission computed tomography (SPECT) has limited ability to identify multivessel and microvascular coronary artery disease. Gamma cameras with cadmium zinc telluride detectors allow the quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR). However, evidence of its accuracy is limited, and of its reproducibility is lacking. We aimed to validate 99m Tc-sestamibi SPECT MBF and MFR using standard and spline-fitted reconstruction algorithms compared with 13 N-ammonia positron emission tomography in a cohort of patients with known or suspected coronary artery disease and to evaluate the reproducibility of this technique. Methods: Accuracy was assessed in 34 participants who underwent dynamic 99m Tc-sestamibi SPECT and 13 N-ammonia positron emission tomography and reproducibility in 14 participants who underwent 2 99m Tc-sestamibi SPECT studies, all within 2 weeks. A rest/pharmacological stress single-day SPECT protocol was performed. SPECT images were reconstructed using a standard ordered subset expectation maximization (OSEM) algorithm with (N=21) and without (N=30) application of spline fitting. SPECT MBF was quantified using a net retention kinetic model‚ and MFR was derived as the stress/rest MBF ratio. Results: SPECT global MBF with splines showed good correlation with 13 N-ammonia positron emission tomography (r=0.81, P P P P =0.07, for MBF and MFR, respectively). Reproducibility of global MBF estimates with splines in paired SPECT scans was good (r=0.77, P P 0.05 for all). Conclusions: MBF and MFR quantification using 99m Tc-sestamibi cadmium zinc telluride SPECT with spatiotemporal spline fitting improved the correlation with 13 N-ammonia positron emission tomography flow estimates and test/retest reproducibility. The use of splines may represent an important step toward the standardization of SPECT flow estimation.
- 29 June 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 33 (12) , 2049-2056
Prognostic value of a faster, low-radiation myocardial perfusion SPECT protocol in a CZT camera
To determine the prognostic value of a new, ultrafast, low dose myocardial perfusion SPECT (MPS) protocol in a cadmium-zinc telluride (CZT) camera. CZT cameras have introduced significant progress in MPS imaging, offering high-quality images despite lower doses and scan time. Yet, it is unknown if, with such protocol changes, the prognostic value of MPS is preserved. Patients had a 1-day 99 m-Tc-sestamibi protocol, starting with the rest (185–222 MBq) followed by stress (666–740 MBq). Acquisition times were 6 and 3 min, respectively. MPS were classified as normal or abnormal perfusion scans and summed scores of stress, rest, and difference (SSS, SRS and SDS), calculated. Patients were followed with 6-month phone calls. Hard events were defined as death or nonfatal myocardial infarction. Late revascularization was that occurring after 60 days of MPS. 2930 patients (age 64.0 ± 12.1 years, 53.3% male) were followed for 30.7 ± 7.5 months. Mean dosimetry was 6 mSv and mean total study time, 48 ± 13 min. The annual hard event and late revascularization rate were higher in patients with greater extension of defect and ischemia. SSS was higher in patients with hard events compared to those without events (2.6 ± 4.9 vs. 5.0 ± 6.3, p < 0.001), as well as the SDS (0.7 ± 1.9 vs. 1.7 ± 3.4, p < 0.00). The same was true for patients with or without late revascularization (SSS: 2.5 ± 4.7 vs. 6.6 ± 7.1; SDS: 0.6 ± 1.7 vs. 2.9 ± 3.8, p < 0.01). A new, faster, low-radiation, MPS protocol in a CZT camera maintain the ability to stratify patients with increased risk of events, showing that, in the presence of greater extension of defect or ischemia, patients presented higher rates of hard events and late revascularization.
- 29 June 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 33 (12) , 2049-2056
Prognostic value of a faster, low-radiation myocardial perfusion SPECT protocol in a CZT camera
To determine the prognostic value of a new, ultrafast, low dose myocardial perfusion SPECT (MPS) protocol in a cadmium-zinc telluride (CZT) camera. CZT cameras have introduced significant progress in MPS imaging, offering high-quality images despite lower doses and scan time. Yet, it is unknown if, with such protocol changes, the prognostic value of MPS is preserved. Patients had a 1-day 99 m-Tc-sestamibi protocol, starting with the rest (185–222 MBq) followed by stress (666–740 MBq). Acquisition times were 6 and 3 min, respectively. MPS were classified as normal or abnormal perfusion scans and summed scores of stress, rest, and difference (SSS, SRS and SDS), calculated. Patients were followed with 6-month phone calls. Hard events were defined as death or nonfatal myocardial infarction. Late revascularization was that occurring after 60 days of MPS. 2930 patients (age 64.0 ± 12.1 years, 53.3% male) were followed for 30.7 ± 7.5 months. Mean dosimetry was 6 mSv and mean total study time, 48 ± 13 min. The annual hard event and late revascularization rate were higher in patients with greater extension of defect and ischemia. SSS was higher in patients with hard events compared to those without events (2.6 ± 4.9 vs. 5.0 ± 6.3, p < 0.001), as well as the SDS (0.7 ± 1.9 vs. 1.7 ± 3.4, p < 0.00). The same was true for patients with or without late revascularization (SSS: 2.5 ± 4.7 vs. 6.6 ± 7.1; SDS: 0.6 ± 1.7 vs. 2.9 ± 3.8, p < 0.01). A new, faster, low-radiation, MPS protocol in a CZT camera maintain the ability to stratify patients with increased risk of events, showing that, in the presence of greater extension of defect or ischemia, patients presented higher rates of hard events and late revascularization.
- 1 May 2017
- Published by Elsevier in Obesity Research & Clinical Practice
- Vol. 11 (3) , 315-323
“Metabolically healthy” obesity: Prevalence, clinical features and association with myocardial ischaemia
- 1 May 2017
- Published by Elsevier in Obesity Research & Clinical Practice
- Vol. 11 (3) , 315-323
“Metabolically healthy” obesity: Prevalence, clinical features and association with myocardial ischaemia
- 1 February 2017
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 24 (1) , 245-251
Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera
- 1 February 2017
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 24 (1) , 245-251
Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera
- 30 September 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (2) , 355-361
Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera
The purpose of this study is to evaluate the prognostic value of myocardial perfusion SPECT obtained in CZT cameras (CZT–SPECT) with multipinhole collimation in obese patients. CZT–SPECT may be technically challenging in the obese, and its prognostic value remains largely unknown. Patients underwent single-day, rest/stress (supine and prone) imaging. Images were visually inspected and graded as poor, fair or good/excellent. Summed stress and difference scores (SSS and SDS, respectively) were converted into percentages of total perfusion defect and of ischemic defect by division by the maximum possible score. Obesity was defined as a body mass index (BMI) ≥ 30 kg/m2 and classified as class I (BMI 30–34.9 kg/m2), II (BMI 35–39.9 kg/m2), or III (BMI ≥ 40 kg/m2). Patients were followed-up by telephone interview for the occurrence of all-cause death, myocardial infarction or revascularization. A Cox proportional hazards analysis was used to assess the independent predictors of death. Among 1396 patients, 365 (26.1 %) were obese (mean BMI 33.9 ± 3.6; 17.5 % class I, 3.4 % class II, and 3.4 % class III). Image quality was good/excellent in 94.5 % of the obese patients. The annualized mortality rates were not significantly different among obese and non-obese patients, being <1 % with normal CZT–SPECT, and increased with the degree of scan abnormality in both obese and non-obese patients. Age, the use of pharmacologic stress and an abnormal CZT–SPECT, but not obesity, were independent predictors of death. In obese patients, single-day rest/stress CZT–SPECT with a multipinhole camera provides prognostic discrimination with high image quality.
- 30 September 2015
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (2) , 355-361
Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera
The purpose of this study is to evaluate the prognostic value of myocardial perfusion SPECT obtained in CZT cameras (CZT–SPECT) with multipinhole collimation in obese patients. CZT–SPECT may be technically challenging in the obese, and its prognostic value remains largely unknown. Patients underwent single-day, rest/stress (supine and prone) imaging. Images were visually inspected and graded as poor, fair or good/excellent. Summed stress and difference scores (SSS and SDS, respectively) were converted into percentages of total perfusion defect and of ischemic defect by division by the maximum possible score. Obesity was defined as a body mass index (BMI) ≥ 30 kg/m2 and classified as class I (BMI 30–34.9 kg/m2), II (BMI 35–39.9 kg/m2), or III (BMI ≥ 40 kg/m2). Patients were followed-up by telephone interview for the occurrence of all-cause death, myocardial infarction or revascularization. A Cox proportional hazards analysis was used to assess the independent predictors of death. Among 1396 patients, 365 (26.1 %) were obese (mean BMI 33.9 ± 3.6; 17.5 % class I, 3.4 % class II, and 3.4 % class III). Image quality was good/excellent in 94.5 % of the obese patients. The annualized mortality rates were not significantly different among obese and non-obese patients, being <1 % with normal CZT–SPECT, and increased with the degree of scan abnormality in both obese and non-obese patients. Age, the use of pharmacologic stress and an abnormal CZT–SPECT, but not obesity, were independent predictors of death. In obese patients, single-day rest/stress CZT–SPECT with a multipinhole camera provides prognostic discrimination with high image quality.